RECORD
Position resolution with 25 um pitch pixel sensors before and after irradiation
Instrumentation and Detectors · Submitted 9 Jul 2021
abstract compiled · 2026-09-23 · no language-model review
The authors' main claim The resolution is 5.0 +/- 0.2 um for a proton-irradiated sensor at F_eq = 2.1 10^15 cm-2 and a neutron-irradiated sensor at F_eq = 3.6 10^15 cm^-2.
The compiled record
The paper's own sentences, arranged. Each label is drawn from a closed vocabulary; the number beside it is the probability the classifier gave that label. Numbers in the tables are the authors', checked by code. No sentence in this record was written by a model.
Open the compiled record
The abstract, sentence by sentence
Pixelated silicon detectors are state-of-the-art technology to achieve precise tracking and vertexing at collider experiments, designed to accurately measure the hit position of incoming particles in high rate and radiation environments. The detector requirements become extremely demanding for operation at the High-Luminosity LHC, where up to 200 interactions will overlap in the same bunch crossing on top of the process of interest. Additionally, fluences up to 2.3 10^16 cm^-2 1 MeV neutron equivalent at 3.0 cm distance from the beam are expected for an integrated luminosity of 3000 fb^-1. In the last decades, the pixel pitch has constantly been reduced to cope with the experiment's needs of achieving higher position resolution and maintaining low pixel occupancy per channel. The spatial resolution improves with a decreased pixel size but it degrades with radiation damage. Therefore, prototype sensor modules for the upgrade of the experiments at the HL-LHC need to be tested after being irradiated. This paper describes position resolution measurements on planar prototype sensors with 100x25 um^2 pixels for the CMS Phase-2 Upgrade. It reviews the dependence of the position resolution on the relative inclination angle between the incoming particle trajectory and the sensor, the charge threshold applied by the readout chip, and the bias voltage. A precision setup with three parallel planes of sensors has been used to investigate the performance of sensors irradiated to fluences up to F_eq = 3.6 10^15 cm-2. The measurements were performed with a 5 GeV electron beam. A spatial resolution of 3.2 +\- 0.1 um is found for non-irradiated sensors, at the optimal angle for charge sharing. The resolution is 5.0 +/- 0.2 um for a proton-irradiated sensor at F_eq = 2.1 10^15 cm-2 and a neutron-irradiated sensor at F_eq = 3.6 10^15 cm^-2.
background contribution method result interpretation main claim
| # | sentence | role | the authors' own work | states the main conclusion | strength |
|---|---|---|---|---|---|
| s0 | Pixelated silicon detectors are state-of-the-art technology to achieve precise tracking and vertexing at collider experiments, designed to accurately measure the hit position of incoming particles in high rate and radiation environments. | background 1.00 | 0.04 | 0.02 | asserted 1.00 |
| s1 | The detector requirements become extremely demanding for operation at the High-Luminosity LHC, where up to 200 interactions will overlap in the same bunch crossing on top of the process of interest. | background 1.00 | 0.04 | 0.02 | asserted 1.00 |
| s2 | Additionally, fluences up to 2.3 10^16 cm^-2 1 MeV neutron equivalent at 3.0 cm distance from the beam are expected for an integrated luminosity of 3000 fb^-1. | background 1.00 | 0.07 | 0.02 | asserted 0.70 |
| s3 | In the last decades, the pixel pitch has constantly been reduced to cope with the experiment's needs of achieving higher position resolution and maintaining low pixel occupancy per channel. | background 1.00 | 0.05 | 0.02 | asserted 1.00 |
| s4 | The spatial resolution improves with a decreased pixel size but it degrades with radiation damage. | background 0.99 | 0.10 | 0.06 | asserted 1.00 |
| s5 | Therefore, prototype sensor modules for the upgrade of the experiments at the HL-LHC need to be tested after being irradiated. | background 0.66 | 0.10 | 0.03 | asserted 0.98 |
| s6 | This paper describes position resolution measurements on planar prototype sensors with 100x25 um^2 pixels for the CMS Phase-2 Upgrade. | contribution 1.00 | 0.85 | 0.07 | asserted 0.98 |
| s7 | It reviews the dependence of the position resolution on the relative inclination angle between the incoming particle trajectory and the sensor, the charge threshold applied by the readout chip, and the bias voltage. | contribution 0.90 | 0.72 | 0.05 | asserted 0.93 |
| s8 | A precision setup with three parallel planes of sensors has been used to investigate the performance of sensors irradiated to fluences up to F_eq = 3.6 10^15 cm-2. | method 1.00 | 0.93 | 0.05 | asserted 1.00 |
| s9 | The measurements were performed with a 5 GeV electron beam. | method 1.00 | 0.86 | 0.02 | asserted 1.00 |
| s10 | A spatial resolution of 3.2 +\- 0.1 um is found for non-irradiated sensors, at the optimal angle for charge sharing. | result 1.00 | 0.95 | 0.28 | asserted 1.00 |
| s11 | The resolution is 5.0 +/- 0.2 um for a proton-irradiated sensor at F_eq = 2.1 10^15 cm-2 and a neutron-irradiated sensor at F_eq = 3.6 10^15 cm^-2. | result 1.00 | 0.95 | 0.60 | asserted 1.00 |
What was examined, and what was not
- arXiv listing abstract v1
- full text
- figures and tables
- references and citing sentences
- relations to other papers
- P abstract
- S sections
- T body sentences
- C citations
- R cross-paper relations
The paper
Original abstract
Pixelated silicon detectors are state-of-the-art technology to achieve precise tracking and vertexing at collider experiments, designed to accurately measure the hit position of incoming particles in high rate and radiation environments. The detector requirements become extremely demanding for operation at the High-Luminosity LHC, where up to 200 interactions will overlap in the same bunch crossing on top of the process of interest. Additionally, fluences up to 2.3 10^16 cm^-2 1 MeV neutron equivalent at 3.0 cm distance from the beam are expected for an integrated luminosity of 3000 fb^-1. In the last decades, the pixel pitch has constantly been reduced to cope with the experiment's needs of achieving higher position resolution and maintaining low pixel occupancy per channel. The spatial resolution improves with a decreased pixel size but it degrades with radiation damage. Therefore, prototype sensor modules for the upgrade of the experiments at the HL-LHC need to be tested after being irradiated. This paper describes position resolution measurements on planar prototype sensors with 100x25 um^2 pixels for the CMS Phase-2 Upgrade. It reviews the dependence of the position resolution on the relative inclination angle between the incoming particle trajectory and the sensor, the charge threshold applied by the readout chip, and the bias voltage. A precision setup with three parallel planes of sensors has been used to investigate the performance of sensors irradiated to fluences up to F_eq = 3.6 10^15 cm-2. The measurements were performed with a 5 GeV electron beam. A spatial resolution of 3.2 +\- 0.1 um is found for non-irradiated sensors, at the optimal angle for charge sharing. The resolution is 5.0 +/- 0.2 um for a proton-irradiated sensor at F_eq = 2.1 10^15 cm-2 and a neutron-irradiated sensor at F_eq = 3.6 10^15 cm^-2.
Human review