Pith. Sign in

RECORD

Towards skin-acetone monitors with selective sensitivity: dynamics of PANI-CA films

Medical Physics · Submitted 2 Feb 2022

abstract compiled · 2026-09-23 · no language-model review

The authors' main claim This suggests there is sufficient sensitivity and inherent selectivity of the films.

how it is stated · hedged possibility 0.97 read the record →

Comment (0) Read on arXiv ↗
Cite ▾
arXiv ID2202.00869 (version 1)
Pith IDRB6FHLII, Pith's permanent record of this paper and its review
CitationAnthony Annerino, Manoj Srinivasan, Michael Faltas, Pelagia-Irene Gouma. "Towards skin-acetone monitors with selective sensitivity: dynamics of PANI-CA films." arXiv:2202.00869 (2022). https://pith.science/paper/RB6FHLII
Claim paper

The compiled record

The paper's own sentences, arranged. Each label is drawn from a closed vocabulary; the number beside it is the probability the classifier gave that label. Numbers in the tables are the authors', checked by code. No sentence in this record was written by a model.

Open the compiled record

Compiled by classifier-1.13.0 via TypeSafe API, question bank abstract-p1-20260923, 2026-09-23: 1 request, 7,778 input tokens.

What the abstract itself states, as probabilities: claims first 0.06 · states limitation 0.96 · human participants 0.07 · controlled comparison 0.26 · randomized assignment 0.02 · states quantitative result 0.98 · compares with prior results 0.87 · mentions code or data availability 0.03.

The abstract, sentence by sentence

arXiv listing abstract v1. Results and the main claim are underlined; .

Most research aimed at measuring biomarkers on the skin is only concerned with sensing chemicals in sweat using electrical signals, but these methods are not truly non-invasive nor non-intrusive because they require substantial amounts of sweat to get a reading. This project aims to create a truly non-invasive wearable sensor that continuously detects the gaseous acetone (a biomarker related to metabolic disorders) that ambiently comes out of the skin. Composite films of polyaniline and cellulose acetate, exhibiting chemo-mechanical actuation upon exposure to gaseous acetone, were tested in the headspaces above multiple solutions containing acetone, ethanol, and water to gauge response sensitivity, selectivity, and repeatability. The bending of the films in response to exposures to these environments was tracked by an automatic video processing code, which was found to out-perform an off-the-shelf deep neural network-based tracker. Using principal component analysis, we showed that the film bending is low dimensional with over 90% of the shape changes being captured with just two parameters. We constructed forward models to predict shape changes from the known exposure history and found that a linear model can explain 40% of the observed variance in film tip angle changes. We constructed inverse models, going from third order fits of shape changes to acetone concentrations where about 45% of the acetone variation and about 30% of ethanol variation are captured by linear models, and non-linear models did not perform substantially better. This suggests there is sufficient sensitivity and inherent selectivity of the films. These models, however, provide evidence for substantial hysteretic or long-time-scale responses of the PANI films, seemingly due to the presence of water. Further experiments will allow more accurate discrimination of unknown exposure environments.

background contribution method result interpretation main claim

What the classifier reports for each sentence. The number is the probability it gave the label.
#sentencerolethe authors' own workstates the main conclusionstrength
s0 Most research aimed at measuring biomarkers on the skin is only concerned with sensing chemicals in sweat using electrical signals, but these methods are not truly non-invasive nor non-intrusive because they require substantial amounts of sweat to get a reading. background 0.79 0.05 0.02 asserted 1.00
s1 This project aims to create a truly non-invasive wearable sensor that continuously detects the gaseous acetone (a biomarker related to metabolic disorders) that ambiently comes out of the skin. contribution 0.89 0.21 0.05 asserted 0.87
s2 Composite films of polyaniline and cellulose acetate, exhibiting chemo-mechanical actuation upon exposure to gaseous acetone, were tested in the headspaces above multiple solutions containing acetone, ethanol, and water to gauge response sensitivity, selectivity, and repeatability. method 0.87 0.95 0.04 asserted 0.98
s3 The bending of the films in response to exposures to these environments was tracked by an automatic video processing code, which was found to out-perform an off-the-shelf deep neural network-based tracker. method 0.55 0.95 0.03 asserted 1.00
s4 Using principal component analysis, we showed that the film bending is low dimensional with over 90% of the shape changes being captured with just two parameters. result 0.94 0.97 0.05 asserted 1.00
s5 We constructed forward models to predict shape changes from the known exposure history and found that a linear model can explain 40% of the observed variance in film tip angle changes. result 0.91 0.97 0.06 asserted 1.00
s6 We constructed inverse models, going from third order fits of shape changes to acetone concentrations where about 45% of the acetone variation and about 30% of ethanol variation are captured by linear models, and non-linear models did not perform substantially better. result 0.98 0.97 0.15 asserted 1.00
s7 This suggests there is sufficient sensitivity and inherent selectivity of the films. interpretation 1.00 0.80 0.48 hedged possibility 0.97
s8 These models, however, provide evidence for substantial hysteretic or long-time-scale responses of the PANI films, seemingly due to the presence of water. interpretation 0.54 0.89 0.10 hedged possibility 0.59
s9 Further experiments will allow more accurate discrimination of unknown exposure environments. future work 1.00 0.08 0.06 hedged possibility 0.77

What kind of paper the classifier reports this is: empirical study 0.94 · evidence from observation or experiment 1.00.

What was examined, and what was not

sources read
  • arXiv listing abstract v1
not examined
  • full text
  • figures and tables
  • references and citing sentences
  • relations to other papers
levels run
  • P abstract
not run
  • S sections
  • T body sentences
  • C citations
  • R cross-paper relations

Every quoted sentence on this record is the authors'. Every label is from Pith's closed vocabulary, with the probability shown beside it. Every number in the measurements table is the authors', checked by code. Record as JSON

The paper
Original abstract

Most research aimed at measuring biomarkers on the skin is only concerned with sensing chemicals in sweat using electrical signals, but these methods are not truly non-invasive nor non-intrusive because they require substantial amounts of sweat to get a reading. This project aims to create a truly non-invasive wearable sensor that continuously detects the gaseous acetone (a biomarker related to metabolic disorders) that ambiently comes out of the skin. Composite films of polyaniline and cellulose acetate, exhibiting chemo-mechanical actuation upon exposure to gaseous acetone, were tested in the headspaces above multiple solutions containing acetone, ethanol, and water to gauge response sensitivity, selectivity, and repeatability. The bending of the films in response to exposures to these environments was tracked by an automatic video processing code, which was found to out-perform an off-the-shelf deep neural network-based tracker. Using principal component analysis, we showed that the film bending is low dimensional with over 90% of the shape changes being captured with just two parameters. We constructed forward models to predict shape changes from the known exposure history and found that a linear model can explain 40% of the observed variance in film tip angle changes. We constructed inverse models, going from third order fits of shape changes to acetone concentrations where about 45% of the acetone variation and about 30% of ethanol variation are captured by linear models, and non-linear models did not perform substantially better. This suggests there is sufficient sensitivity and inherent selectivity of the films. These models, however, provide evidence for substantial hysteretic or long-time-scale responses of the PANI films, seemingly due to the presence of water. Further experiments will allow more accurate discrimination of unknown exposure environments.

Human review

Discussion

Know something about this paper? Leave a comment, or highlight any passage above to comment on it.