US Velocimetry in Participants with Aortoiliac Occlusive Disease
Medical Physics · Submitted 7 Feb 2022
abstract compiled · 2026-09-23 · no language-model review
The authors' main claim Blood flow quantification with US velocimetry is feasible in patients with an aortoiliac stenosis, but several challenges must be overcome before implementation into clinical practice.
The compiled record
The paper's own sentences, arranged. Each label is drawn from a closed vocabulary; the number beside it is the probability the classifier gave that label. Numbers in the tables are the authors', checked by code. No sentence in this record was written by a model.
Open the compiled record
The abstract, sentence by sentence
The accurate quantification of blood flow in aortoiliac arteries is challenging but clinically relevant because local flow patterns can influence atherosclerotic disease. To investigate the feasibility and clinical application of two-dimensional blood flow quantification using high-frame-rate contrast-enhanced US (HFR-CEUS) and particle image velocimetry (PIV), or US velocimetry, in participants with aortoiliac stenosis. In this prospective study, participants with a recently diagnosed aortoiliac stenosis underwent HFR-CEUS measurements of the pre- and poststenotic vessel segments. Two-dimensional quantification of blood flow was achieved by performing PIV analysis, which was based on pairwise cross-correlation of the HFR-CEUS images. Visual inspection of the entire data set was performed by five observers to evaluate the ability of the technique to enable adequate visualization of blood flow. The contrast-to-background ratio and average vector correlation were calculated. In two participants who showed flow disturbances, the flow complexity and vorticity were calculated. Results: 35 participants were included. Visual scoring showed that flow quantification was achieved in 41 of 42 locations. In 25 locations, one or multiple issues occurred that limited optimal flow quantification, including loss of correlation during systole, shadow regions, a short vessel segment in the image plane, and loss of contrast during diastole. In the remaining 16 locations, optimal quantification was achieved. The contrast-to-background ratio was higher during systole than during diastole, whereas the vector correlation was lower. Flow complexity and vorticity were high in regions with disturbed flow. Blood flow quantification with US velocimetry is feasible in patients with an aortoiliac stenosis, but several challenges must be overcome before implementation into clinical practice.
background contribution method result interpretation main claim
| # | sentence | role | the authors' own work | states the main conclusion | strength |
|---|---|---|---|---|---|
| s0 | The accurate quantification of blood flow in aortoiliac arteries is challenging but clinically relevant because local flow patterns can influence atherosclerotic disease. | background 1.00 | 0.05 | 0.02 | asserted 0.99 |
| s1 | To investigate the feasibility and clinical application of two-dimensional blood flow quantification using high-frame-rate contrast-enhanced US (HFR-CEUS) and particle image velocimetry (PIV), or US velocimetry, in participants with aortoiliac stenosis. | contribution 0.95 | 0.35 | 0.02 | unclear 0.83 |
| s2 | In this prospective study, participants with a recently diagnosed aortoiliac stenosis underwent HFR-CEUS measurements of the pre- and poststenotic vessel segments. | method 0.92 | 0.96 | 0.02 | asserted 0.97 |
| s3 | Two-dimensional quantification of blood flow was achieved by performing PIV analysis, which was based on pairwise cross-correlation of the HFR-CEUS images. | method 1.00 | 0.93 | 0.02 | asserted 1.00 |
| s4 | Visual inspection of the entire data set was performed by five observers to evaluate the ability of the technique to enable adequate visualization of blood flow. | method 1.00 | 0.93 | 0.01 | asserted 0.80 |
| s5 | The contrast-to-background ratio and average vector correlation were calculated. | method 1.00 | 0.94 | 0.01 | asserted 0.88 |
| s6 | In two participants who showed flow disturbances, the flow complexity and vorticity were calculated. | method 0.97 | 0.96 | 0.01 | asserted 0.95 |
| s7 | Results: 35 participants were included. | result 0.88 | 0.92 | 0.01 | asserted 0.99 |
| s8 | Visual scoring showed that flow quantification was achieved in 41 of 42 locations. | result 1.00 | 0.96 | 0.04 | asserted 1.00 |
| s9 | In 25 locations, one or multiple issues occurred that limited optimal flow quantification, including loss of correlation during systole, shadow regions, a short vessel segment in the image plane, and loss of contrast during diastole. | result 0.90 | 0.95 | 0.02 | asserted 1.00 |
| s10 | In the remaining 16 locations, optimal quantification was achieved. | result 1.00 | 0.94 | 0.04 | asserted 1.00 |
| s11 | The contrast-to-background ratio was higher during systole than during diastole, whereas the vector correlation was lower. | result 1.00 | 0.95 | 0.03 | asserted 1.00 |
| s12 | Flow complexity and vorticity were high in regions with disturbed flow. | result 1.00 | 0.95 | 0.03 | asserted 1.00 |
| s13 | Blood flow quantification with US velocimetry is feasible in patients with an aortoiliac stenosis, but several challenges must be overcome before implementation into clinical practice. | interpretation 0.96 | 0.85 | 0.97 | asserted 0.98 |
What was examined, and what was not
- arXiv listing abstract v1
- full text
- figures and tables
- references and citing sentences
- relations to other papers
- P abstract
- S sections
- T body sentences
- C citations
- R cross-paper relations
The paper
Original abstract
The accurate quantification of blood flow in aortoiliac arteries is challenging but clinically relevant because local flow patterns can influence atherosclerotic disease. To investigate the feasibility and clinical application of two-dimensional blood flow quantification using high-frame-rate contrast-enhanced US (HFR-CEUS) and particle image velocimetry (PIV), or US velocimetry, in participants with aortoiliac stenosis. In this prospective study, participants with a recently diagnosed aortoiliac stenosis underwent HFR-CEUS measurements of the pre- and poststenotic vessel segments. Two-dimensional quantification of blood flow was achieved by performing PIV analysis, which was based on pairwise cross-correlation of the HFR-CEUS images. Visual inspection of the entire data set was performed by five observers to evaluate the ability of the technique to enable adequate visualization of blood flow. The contrast-to-background ratio and average vector correlation were calculated. In two participants who showed flow disturbances, the flow complexity and vorticity were calculated. Results: 35 participants were included. Visual scoring showed that flow quantification was achieved in 41 of 42 locations. In 25 locations, one or multiple issues occurred that limited optimal flow quantification, including loss of correlation during systole, shadow regions, a short vessel segment in the image plane, and loss of contrast during diastole. In the remaining 16 locations, optimal quantification was achieved. The contrast-to-background ratio was higher during systole than during diastole, whereas the vector correlation was lower. Flow complexity and vorticity were high in regions with disturbed flow. Blood flow quantification with US velocimetry is feasible in patients with an aortoiliac stenosis, but several challenges must be overcome before implementation into clinical practice.