Pith. sign in

REVIEW

On the use of ferroelectric material in the detection of dark matter axions

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2204.11919 v2 pith:OY3FOMKG submitted 2022-04-25 physics.ins-det hep-ex

On the use of ferroelectric material in the detection of dark matter axions

classification physics.ins-det hep-ex
keywords tuningaxionsdarkferroelectricmattersystemscavitieshaloscopes
verification ladder T0 review T1 audit T2 compute T3 formal T4 reserved
0 comments
read the original abstract

Tuning is an essential requirement for the search of dark matter axions employing haloscopes since its mass is not known yet to the scientific community. At the present day, most haloscope tuning systems are based on mechanical devices which can lead to failures due to the complexity of the environment in which they are used. However, the electronic tuning making use of ferroelectric materials can provide a path that is less vulnerable to mechanical failures and thus complements and expands current tuning systems. In this work, we present and design a novel concept for using the ferroelectric Potassium Tantalate ($KTaO_3$ or KTO) material as a tuning element in haloscopes based on coupled microwave cavities. In this line, the structures used in the Relic Axion Detector Exploratory Setup (RADES) group are based on several cavities that are connected by metallic irises, which act as interresonator coupling elements. In this article, we also show how to use these $KTaO_3$ films as interresonator couplings between cavities, instead of inductive or capacitive metallic windows used in the past. These two concepts represent a crucial upgrade over the current systems employed in the dark matter axions community, achieving a tuning range of $2.23 \, \%$ which represents a major improvement as compared to previous works ($<0.1 \, \%$) for the same class of tuning systems. The theoretical and simulated results shown in this work demonstrate the interest of the novel concepts proposed for the incorporation of this kind of ferroelectric media in multicavity resonant haloscopes in the search for dark matter axions.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.