Pith. sign in

REVIEW 1 cited by

Choice of training label matters: how to best use deep learning for quantitative MRI parameter estimation

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2205.05587 v3 pith:DVSVKMV6 submitted 2022-05-11 physics.med-ph cs.LGeess.IV

classification physics.med-phcs.LGeess.IV
keywords learningsupervisedparameterbeenestimationlabelsself-supervisedtraining
verification ladder T0 review T1 audit T2 compute T3 formal

Signed reviews

No signed human review yet.

0 comments
read the original abstract

Deep learning (DL) is gaining popularity as a parameter estimation method for quantitative MRI. A range of competing implementations have been proposed, relying on either supervised or self-supervised learning. Self-supervised approaches, sometimes referred to as unsupervised, have been loosely based on auto-encoders, whereas supervised methods have, to date, been trained on groundtruth labels. These two learning paradigms have been shown to have distinct strengths. Notably, self-supervised approaches have offered lower-bias parameter estimates than their supervised alternatives. This result is counterintuitive - incorporating prior knowledge with supervised labels should, in theory, lead to improved accuracy. In this work, we show that this apparent limitation of supervised approaches stems from the naive choice of groundtruth training labels. By training on labels which are deliberately not groundtruth, we show that the low-bias parameter estimation previously associated with self-supervised methods can be replicated - and improved on - within a supervised learning framework. This approach sets the stage for a single, unifying, deep learning parameter estimation framework, based on supervised learning, where trade-offs between bias and variance are made by careful adjustment of training label.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. MRI Parameter Mapping via Gaussian Mixture VAE: Breaking the Assumption of Independent Pixels

    eess.IV 2024-11 conditional novelty 5.0 of 10

    A Gaussian mixture VAE produces sharper, less noisy diffusion MRI parameter maps than voxel-wise least-squares and self-supervised baselines.

Pith tools