Pith. sign in

REVIEW

High precision measurement of the $^6$He half-life

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2207.06071 v2 pith:F6PB3SMO submitted 2022-07-13 nucl-ex

classification nucl-ex
keywords eventshalf-lifemeasurementprecisionacquisitionbeambeenconsistent
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
abstract

The half-life of $^{6}$He has been measured using a low energy radioactive beam implanted in a YAP scintillator and recording decay events in a 4$\pi$ geometry. Events were time-stamped with a digital data acquisition system enabling a reliable control of dead-time effects and detector gain variations. The result, $T_{1/2} = (807.25 \pm 0.16_{\rm stat} \pm 0.11_{\rm sys}$)~ms, provides the most precise value obtained so far and is consistent with the only previous measurement having a precision smaller than 0.1%. This resolves the longstanding discrepancy previously observed between two sets of measurements.

Discussion (0). Continue with ORCID to comment.

Pith tools