Flow Rate Independent Multiscale Liquid Biopsy for Precision Oncology
Pith reviewed 2026-05-24 11:23 UTC · model grok-4.3
The pith
A multiscale mesh device captures circulating tumor cells with constant efficiency above 75 percent across flow rates from 50 to 200 microliters per minute.
A machine-rendered reading of the paper's core claim, the machinery that carries it, and where it could break.
Core claim
By decoupling and independently optimizing the nano-, micro- and macro-scales of an enrichment device that is simple to fabricate and operate, the scalable mesh approach enables optimum capture conditions at any flow rate, demonstrated with constant capture efficiencies above 75 percent between 50-200 uL/min. The device detected CTCs with 96 percent sensitivity and 100 percent specificity in 79 cancer patients and 20 healthy controls and supports post-processing such as identifying responders to immune checkpoint inhibition and detecting HER2 positive breast cancer, with results that compare well with other assays including clinical standards.
What carries the argument
The scalable mesh approach that decouples and independently optimizes the nano-, micro-, and macro-scales of the enrichment device to maintain capture efficiency independent of flow rate.
If this is right
- Higher sample volumes can be processed without loss of capture performance.
- Post-processing steps remain compatible, allowing identification of therapy responders and specific markers such as HER2.
- The method performs at levels comparable to existing clinical assays.
- Fabrication and operation are simplified relative to other affinity-based devices.
Where Pith is reading between the lines
- Flow-rate independence may allow the device to work with varying clinical equipment or sample volumes without recalibration.
- The same mesh design principle could be tested on other rare cell types or biomarkers beyond tumor cells.
- Larger or more varied patient groups would be needed to confirm whether the reported sensitivity and specificity hold outside the initial cohort.
Load-bearing premise
Tuning the binding sites, flow paths, and overall device size separately will keep capture rates steady no matter the speed of the blood flow, without hurting accuracy or later lab work.
What would settle it
An experiment that measures capture efficiency at several flow rates between 50 and 200 uL/min and finds the efficiency drops below 75 percent at any tested speed.
Figures
read the original abstract
Immunoaffinity-based liquid biopsies of circulating tumor cells (CTCs) hold great promise for cancer management, but typically suffer from low throughput, relative complexity and post-processing limitations. Here we address these issues simultaneously by decoupling and independently optimizing the nano-, micro- and macro-scales of an enrichment device that is simple to fabricate and operate. Unlike other affinity-based devices, our scalable mesh approach enables optimum capture conditions at any flow rate, as demonstrated with constant capture efficiencies, above 75% between 50-200 uL/min. The device achieved 96% sensitivity and 100% specificity when used to detect CTCs in the blood of 79 cancer patients and 20 healthy controls. We demonstrate its post processing capacity with the identification of potential responders to immune checkpoint inhibition therapy and the detection of HER2 positive breast cancer. The results compare well with other assays, including clinical standards. This suggests that our approach, which overcomes major limitations associated with affinity-based liquid biopsies, could help improve cancer management.
Editorial analysis
A structured set of objections, weighed in public.
Referee Report
Summary. The manuscript describes a multiscale mesh-based immunoaffinity device for CTC enrichment that decouples and independently optimizes nano-, micro-, and macro-scales to achieve flow-rate-independent capture. It reports constant efficiencies above 75% across 50-200 µL/min, 96% sensitivity and 100% specificity on 79 cancer patients and 20 healthy controls, plus post-processing applications for immune checkpoint response prediction and HER2 detection, claiming advantages over existing affinity-based liquid biopsies.
Significance. If the flow-rate independence and clinical metrics are substantiated with full methods and mechanistic support, the approach could meaningfully improve CTC liquid biopsy throughput and operational simplicity, addressing key limitations of current affinity devices while maintaining compatibility with downstream analyses.
major comments (2)
- [Abstract] Abstract: The central claim that independent optimization of the three scales produces optimum capture conditions at any flow rate (constant efficiency >75% from 50-200 µL/min) is presented without any design rules, equations, or optimization framework that maps nano-scale antibody density, micro-scale mesh geometry, and macro-scale device dimensions onto a flow-rate-independent capture probability. The text proceeds directly from the assertion of scale decoupling to the empirical flat efficiency curve, leaving the mechanistic basis for generality unaddressed.
- [Abstract] Abstract (performance metrics): The reported 96% sensitivity and 100% specificity are stated without error bars, patient cohort stratification details, or direct head-to-head comparison data against clinical standards within the provided text; this weakens the claim that results 'compare well with other assays' and requires the full methods and results sections to verify load-bearing clinical performance.
minor comments (1)
- [Abstract] Abstract: Units are written as 'uL/min' rather than the conventional 'µL/min'.
Simulated Author's Rebuttal
We thank the referee for their constructive comments on our manuscript. We address each major comment point by point below, providing clarifications from the full text and indicating revisions where they strengthen the presentation without altering the core findings.
read point-by-point responses
-
Referee: [Abstract] Abstract: The central claim that independent optimization of the three scales produces optimum capture conditions at any flow rate (constant efficiency >75% from 50-200 µL/min) is presented without any design rules, equations, or optimization framework that maps nano-scale antibody density, micro-scale mesh geometry, and macro-scale device dimensions onto a flow-rate-independent capture probability. The text proceeds directly from the assertion of scale decoupling to the empirical flat efficiency curve, leaving the mechanistic basis for generality unaddressed.
Authors: The abstract is intentionally concise. The full manuscript (Methods and Results sections) details the multiscale optimization framework, including how nano-scale antibody density, micro-scale mesh geometry parameters, and macro-scale device dimensions are independently tuned to yield flow-rate-independent capture probability. Supporting equations, design rules, and mechanistic rationale for the observed flat efficiency curve (constant >75% from 50-200 µL/min) are provided there, along with experimental validation. We will revise the abstract to include a brief clause referencing this optimization framework and its role in achieving generality. revision: yes
-
Referee: [Abstract] Abstract (performance metrics): The reported 96% sensitivity and 100% specificity are stated without error bars, patient cohort stratification details, or direct head-to-head comparison data against clinical standards within the provided text; this weakens the claim that results 'compare well with other assays' and requires the full methods and results sections to verify load-bearing clinical performance.
Authors: The abstract summarizes the primary clinical metrics from the 79-patient/20-control cohort. Full details—including error bars or confidence intervals, cohort stratification by cancer type/stage, and comparisons to literature values for other assays and clinical standards—are reported in the Results and Discussion sections. The claim of comparing well is based on those data. We will revise the abstract to note the cohort size and indicate that detailed verification appears in the main text, while preserving abstract length constraints. revision: partial
Circularity Check
No circularity; purely experimental results with no derivation chain
full rationale
The paper reports direct experimental measurements of capture efficiency across flow rates and clinical performance metrics from patient samples. No equations, models, predictions, or first-principles derivations are present that could reduce to fitted inputs or self-referential definitions. The multiscale optimization is asserted as a design premise but is not linked to any mathematical framework whose output would be forced by its own inputs. Self-citations, if present, are not load-bearing for any claimed result. The work is therefore self-contained against external benchmarks via empirical validation.
Axiom & Free-Parameter Ledger
Reference graph
Works this paper leans on
-
[1]
Liquid biopsy and minimal residual disease — latest advances and implications for cure,
K. Pantel and C. Alix-Panabières, “Liquid biopsy and minimal residual disease — latest advances and implications for cure,” Nat Rev Clin Oncol, vol. 16, no. 7, pp. 409–424, Jul. 2019, doi: 10.1038/s41571-019-0187-3
-
[2]
D. Pappas, “Microfluidics and cancer analysis: cell separation, cell/tissue culture, cell mechanics, and integrated analysis systems,” Analyst, vol. 141, no. 2, pp. 525–535, 2016, doi: 10.1039/C5AN01778E
-
[3]
Cancer diagnosis: from tumor to liquid biopsy and beyond,
R. Vaidyanathan, R. Hao Soon, P. Zhang, K. Jiang, and C. Teck Lim, “Cancer diagnosis: from tumor to liquid biopsy and beyond,” Lab on a Chip, vol. 19, no. 1, pp. 11–34, 2019, doi: 10.1039/C8LC00684A
-
[4]
E. Zhou et al., “Circulating extracellular vesicles are effective biomarkers for predicting response to cancer therapy,” EBioMedicine, vol. 67, p. 103365, May 2021, doi: 10.1016/j.ebiom.2021.103365
-
[5]
Tumor Self-Seeding by Circulating Cancer Cells,
M.-Y. Kim et al., “Tumor Self-Seeding by Circulating Cancer Cells,” Cell, vol. 139, no. 7, pp. 1315–1326, Dec. 2009, doi: 10.1016/j.cell.2009.11.025
-
[6]
M. Krebs et al., “Evaluation and Prognostic Significance of Circulating Tumor Cells in Patients With Non-Small-Cell Lung Cancer,” Journal of clinical oncology : official journal of the American Society of Clinical Oncology, vol. 29, pp. 1556–63, Mar. 2011, doi: 10.1200/JCO.2010.28.7045
-
[7]
Capture of Viable Circulating Tumor Cells in the Liver of Colorectal Cancer Patients,
E. Denève et al., “Capture of Viable Circulating Tumor Cells in the Liver of Colorectal Cancer Patients,” Clinical Chemistry, vol. 59, no. 9, pp. 1384–1392, Sep. 2013, doi: 10.1373/clinchem.2013.202846
-
[8]
Circulating tumor cells in clinical research and monitoring patients with colorectal cancer,
C. Burz et al., “Circulating tumor cells in clinical research and monitoring patients with colorectal cancer,” Oncotarget, vol. 9, no. 36, pp. 24561–24571, May 2018, doi: 10.18632/oncotarget.25337
-
[9]
Z. Eslami-S, L. E. Cortés-Hernández, F. Thomas, K. Pantel, and C. Alix-Panabières, “Functional analysis of circulating tumour cells: the KEY to understand the biology of the metastatic cascade,” Br J Cancer, pp. 1–11, Apr. 2022, doi: 10.1038/s41416-022-01819-1
-
[10]
Circulating tumor cell technologies,
M. M. Ferreira, V. C. Ramani, and S. S. Jeffrey, “Circulating tumor cell technologies,” Molecular Oncology, vol. 10, no. 3, pp. 374–394, Mar. 2016, doi: 10.1016/j.molonc.2016.01.007
-
[11]
Isolation of rare circulating tumour cells in cancer patients by microchip technology,
S. Nagrath et al., “Isolation of rare circulating tumour cells in cancer patients by microchip technology,” Nature, vol. 450, no. 7173, pp. 1235–1239, Dec. 2007, doi: 10.1038/nature06385
-
[12]
J. C. Fischer et al., “Diagnostic leukapheresis enables reliable detection of circulating tumor cells of nonmetastatic cancer patients,” PNAS, vol. 110, no. 41, pp. 16580–16585, Oct. 2013, doi: 10.1073/pnas.1313594110
-
[13]
W. J. Allard et al., “Tumor Cells Circulate in the Peripheral Blood of All Major Carcinomas but not in Healthy Subjects or Patients With Nonmalignant Diseases,” Clin Cancer Res, vol. 10, no. 20, pp. 6897–6904, Oct. 2004, doi: 10.1158/1078-0432.CCR-04-0378
-
[14]
J.-F. Chen et al., “Subclassification of prostate cancer circulating tumor cells by nuclear size reveals very small nuclear circulating tumor cells in patients with visceral metastases,” Cancer, vol. 121, no. 18, pp. 3240–3251, 2015, doi: 10.1002/cncr.29455
-
[15]
M. G. Ahmed et al., “Isolation, Detection, and Antigen-Based Profiling of Circulating Tumor Cells Using a Size-Dictated Immunocapture Chip,” Angewandte Chemie International Edition, vol. 56, no. 36, pp. 10681–10685, 2017, doi: 10.1002/anie.201702675
-
[16]
Microfluidic, marker-free isolation of circulating tumor cells from blood samples,
N. M. Karabacak et al., “Microfluidic, marker-free isolation of circulating tumor cells from blood samples,” Nat Protoc, vol. 9, no. 3, Art. no. 3, Mar. 2014, doi: 10.1038/nprot.2014.044
-
[17]
Single-Cell Phenotypic Profiling of CTCs in Whole Blood Using an Integrated Microfluidic Device,
H. Pei et al., “Single-Cell Phenotypic Profiling of CTCs in Whole Blood Using an Integrated Microfluidic Device,” Anal. Chem., vol. 91, no. 17, pp. 11078–11084, Sep. 2019, doi: 10.1021/acs.analchem.9b01647. 17
-
[18]
A. Mishra et al., “Ultrahigh-throughput magnetic sorting of large blood volumes for epitope- agnostic isolation of circulating tumor cells,” Proceedings of the National Academy of Sciences, vol. 117, no. 29, pp. 16839–16847, Jul. 2020, doi: 10.1073/pnas.2006388117
-
[19]
Microfluidic Screening of Circulating Tumor Biomarkers toward Liquid Biopsy,
N. Hao and J. X. J. Zhang, “Microfluidic Screening of Circulating Tumor Biomarkers toward Liquid Biopsy,” Separation & Purification Reviews, vol. 47, no. 1, pp. 19–48, Jan. 2018, doi: 10.1080/15422119.2017.1320763
-
[20]
Circulating Tumor Cells: Liquid Biopsy of Cancer,
C. Alix-Panabières and K. Pantel, “Circulating Tumor Cells: Liquid Biopsy of Cancer,” Clinical Chemistry, vol. 59, no. 1, pp. 110–118, Jan. 2013, doi: 10.1373/clinchem.2012.194258
-
[21]
Microfluidics for Liquid Biopsies: Recent Advances, Current Challenges, and Future Directions,
Y. Belotti and C. T. Lim, “Microfluidics for Liquid Biopsies: Recent Advances, Current Challenges, and Future Directions,” Anal. Chem., vol. 93, no. 11, pp. 4727–4738, Mar. 2021, doi: 10.1021/acs.analchem.1c00410
-
[22]
Specific Capture and Release of Circulating Tumor Cells Using Aptamer- Modified Nanosubstrates,
Q. Shen et al., “Specific Capture and Release of Circulating Tumor Cells Using Aptamer- Modified Nanosubstrates,” Advanced Materials, vol. 25, no. 16, pp. 2368–2373, 2013, doi: 10.1002/adma.201300082
-
[23]
NanoVelcro Chip for CTC enumeration in prostate cancer patients,
Y.-T. Lu et al., “NanoVelcro Chip for CTC enumeration in prostate cancer patients,” Methods, vol. 64, no. 2, pp. 144–152, Dec. 2013, doi: 10.1016/j.ymeth.2013.06.019
-
[24]
System Modularity Chip for Analysis of Rare Targets (SMART-Chip): Liquid Biopsy Samples,
T. N. Pahattuge et al., “System Modularity Chip for Analysis of Rare Targets (SMART-Chip): Liquid Biopsy Samples,” ACS Sens., vol. 6, no. 5, pp. 1831–1839, May 2021, doi: 10.1021/acssensors.0c02728
-
[25]
S. Wang et al., “Highly Efficient Capture of Circulating Tumor Cells by Using Nanostructured Silicon Substrates with Integrated Chaotic Micromixers,” Angewandte Chemie, vol. 123, no. 13, pp. 3140–3144, 2011, doi: 10.1002/ange.201005853
-
[26]
M.-H. Park et al., “Enhanced Isolation and Release of Circulating Tumor Cells Using Nanoparticle Binding and Ligand Exchange in a Microfluidic Chip,” ACS Publications, Feb. 09, 2017. https://pubs.acs.org/doi/pdf/10.1021/jacs.6b12236 (accessed Dec. 31, 2021)
-
[27]
Making it stick: convection, reaction and diffusion in surface-based biosensors,
T. M. Squires, R. J. Messinger, and S. R. Manalis, “Making it stick: convection, reaction and diffusion in surface-based biosensors,” Nat Biotechnol, vol. 26, no. 4, pp. 417–426, Apr. 2008, doi: 10.1038/nbt1388
-
[28]
I. Pereiro, A. Fomitcheva-Khartchenko, and G. V. Kaigala, “Shake It or Shrink It: Mass Transport and Kinetics in Surface Bioassays Using Agitation and Microfluidics,” Analytical Chemistry, Jun. 2020, doi: 10.1021/acs.analchem.0c01625
-
[29]
Transient Convection, Diffusion, and Adsorption in Surface-Based Biosensors,
R. Hansen, H. Bruus, T. H. Callisen, and O. Hassager, “Transient Convection, Diffusion, and Adsorption in Surface-Based Biosensors,” Langmuir, vol. 28, no. 19, pp. 7557–7563, May 2012, doi: 10.1021/la3000763
-
[30]
General model for mass transport to planar and nanowire biosensor surfaces,
D. S. Jin, E. L. Brightbill, and E. M. Vogel, “General model for mass transport to planar and nanowire biosensor surfaces,” Journal of Applied Physics, vol. 125, no. 11, p. 114502, Mar. 2019, doi: 10.1063/1.5084253
-
[31]
EpCAM: Structure and function in health and disease,
U. Schnell, V. Cirulli, and B. N. G. Giepmans, “EpCAM: Structure and function in health and disease,” Biochimica et Biophysica Acta (BBA) - Biomembranes, vol. 1828, no. 8, pp. 1989–2001, Aug. 2013, doi: 10.1016/j.bbamem.2013.04.018
-
[32]
L. Chen et al., “Combined use of EpCAM and FRα enables the high-efficiency capture of circulating tumor cells in non-small cell lung cancer,” Sci Rep, vol. 8, no. 1, p. 1188, Jan. 2018, doi: 10.1038/s41598-018-19391-1
-
[33]
The detection of EpCAM+ and EpCAM– circulating tumor cells,
S. de Wit et al., “The detection of EpCAM+ and EpCAM– circulating tumor cells,” Sci Rep, vol. 5, no. 1, p. 12270, Jul. 2015, doi: 10.1038/srep12270
-
[34]
A. Hatch, G. Hansmann, and S. K. Murthy, “Engineered Alginate Hydrogels for Effective Microfluidic Capture and Release of Endothelial Progenitor Cells from Whole Blood,” Langmuir, vol. 27, no. 7, pp. 4257–4264, Apr. 2011, doi: 10.1021/la105016a. 18
-
[35]
Biopolymer System for Cell Recovery from Microfluidic Cell Capture Devices,
A. M. Shah et al., “Biopolymer System for Cell Recovery from Microfluidic Cell Capture Devices,” Anal. Chem., vol. 84, no. 8, pp. 3682–3688, Apr. 2012, doi: 10.1021/ac300190j
-
[36]
The role of polymers in detection and isolation of circulating tumor cells,
J. Hye Myung, K. A. Gajjar, Y. Eon Han, and S. Hong, “The role of polymers in detection and isolation of circulating tumor cells,” Polymer Chemistry, vol. 3, no. 9, pp. 2336–2341, 2012, doi: 10.1039/C2PY20420G
-
[37]
Emerging microfluidic devices for cancer cells/biomarkers manipulation and detection,
V. H. Perez-Gonzalez, R. C. Gallo-Villanueva, S. Camacho-Leon, J. I. Gomez-Quiñones, J. M. Rodriguez-Delgado, and S. O. Martinez-Chapa, “Emerging microfluidic devices for cancer cells/biomarkers manipulation and detection,” IET Nanobiotechnology, vol. 10, no. 5, pp. 263–275, 2016, doi: 10.1049/iet-nbt.2015.0060
-
[38]
M. Antfolk and T. Laurell, “Continuous flow microfluidic separation and processing of rare cells and bioparticles found in blood – A review,” Analytica Chimica Acta, vol. 965, pp. 9–35, May 2017, doi: 10.1016/j.aca.2017.02.017
-
[39]
3D microfilter device for viable circulating tumor cell (CTC) enrichment from blood,
S. Zheng et al., “3D microfilter device for viable circulating tumor cell (CTC) enrichment from blood,” Biomed Microdevices, vol. 13, no. 1, pp. 203–213, Feb. 2011, doi: 10.1007/s10544-010-9485-3
-
[40]
Filter Characteristics Influencing Circulating Tumor Cell Enrichment from Whole Blood,
F. A. W. Coumans, G. van Dalum, M. Beck, and L. W. M. M. Terstappen, “Filter Characteristics Influencing Circulating Tumor Cell Enrichment from Whole Blood,” PLOS ONE, vol. 8, no. 4, p. e61770, avr 2013, doi: 10.1371/journal.pone.0061770
-
[41]
Microfluidic analysis of circulating tumor cells and tumor-derived extracellular vesicles,
F. Tian, C. Liu, L. Lin, Q. Chen, and J. Sun, “Microfluidic analysis of circulating tumor cells and tumor-derived extracellular vesicles,” TrAC Trends in Analytical Chemistry, vol. 117, pp. 128–145, Aug. 2019, doi: 10.1016/j.trac.2019.05.013
-
[42]
Detachment strategies for affinity-adsorbed cells,
X. Cao, R. Eisenthal, and J. Hubble, “Detachment strategies for affinity-adsorbed cells,” Enzyme and Microbial Technology, vol. 31, no. 1, pp. 153–160, Jul. 2002, doi: 10.1016/S0141-0229(02)00083- 2
-
[43]
Evaluation of PD-L1 expression on vortex-isolated circulating tumor cells in metastatic lung cancer,
M. Dhar et al., “Evaluation of PD-L1 expression on vortex-isolated circulating tumor cells in metastatic lung cancer,” Sci Rep, vol. 8, no. 1, p. 2592, Feb. 2018, doi: 10.1038/s41598-018-19245-w
-
[44]
V. Kloten, R. Lampignano, T. Krahn, and T. Schlange, “Circulating Tumor Cell PD-L1 Expression as Biomarker for Therapeutic Efficacy of Immune Checkpoint Inhibition in NSCLC,” Cells, vol. 8, no. 8, Art. no. 8, Aug. 2019, doi: 10.3390/cells8080809
-
[45]
PD-L1 expressing circulating tumour cells in head and neck cancers,
A. Kulasinghe, C. Perry, L. Kenny, M. E. Warkiani, C. Nelson, and C. Punyadeera, “PD-L1 expressing circulating tumour cells in head and neck cancers,” BMC Cancer, vol. 17, no. 1, p. 333, May 2017, doi: 10.1186/s12885-017-3316-3
-
[46]
M. Janning et al., “Determination of PD-L1 Expression in Circulating Tumor Cells of NSCLC Patients and Correlation with Response to PD-1/PD-L1 Inhibitors,” Cancers, vol. 11, no. 6, Art. no. 6, Jun. 2019, doi: 10.3390/cancers11060835
-
[47]
HER2-family signalling mechanisms, clinical implications and targeting in breast cancer,
N. Elster, D. M. Collins, S. Toomey, J. Crown, A. J. Eustace, and B. T. Hennessy, “HER2-family signalling mechanisms, clinical implications and targeting in breast cancer,” Breast Cancer Res Treat, vol. 149, no. 1, pp. 5–15, Jan. 2015, doi: 10.1007/s10549-014-3250-x
-
[48]
HER2-targeted therapies — a role beyond breast cancer,
D.-Y. Oh and Y.-J. Bang, “HER2-targeted therapies — a role beyond breast cancer,” Nat Rev Clin Oncol, vol. 17, no. 1, pp. 33–48, Jan. 2020, doi: 10.1038/s41571-019-0268-3
-
[49]
HER2 status in breast cancer: changes in guidelines and complicating factors for interpretation,
S. Ahn, J. W. Woo, K. Lee, and S. Y. Park, “HER2 status in breast cancer: changes in guidelines and complicating factors for interpretation,” J Pathol Transl Med, vol. 54, no. 1, pp. 34–44, Jan. 2020, doi: 10.4132/jptm.2019.11.03
-
[50]
P. Wülfing et al., “HER2-Positive Circulating Tumor Cells Indicate Poor Clinical Outcome in Stage I to III Breast Cancer Patients,” Clin Cancer Res, vol. 12, no. 6, pp. 1715–1720, Mar. 2006, doi: 10.1158/1078-0432.CCR-05-2087
-
[51]
T. Huang et al., “Highly sensitive enumeration of circulating tumor cells in lung cancer patients using a size-based filtration microfluidic chip,” Biosensors and Bioelectronics, vol. 51, pp. 213–218, Jan. 2014, doi: 10.1016/j.bios.2013.07.044. 19
-
[52]
J. H. Myung et al., “Multivalent Binding and Biomimetic Cell Rolling Improves the Sensitivity and Specificity of Circulating Tumor Cell Capture,” Clin Cancer Res, vol. 24, no. 11, pp. 2539–2547, Jun. 2018, doi: 10.1158/1078-0432.CCR-17-3078
-
[53]
Dosing time dependent in vitro pharmacodynamics of Everolimus despite a defective circadian clock,
Y. Zhang et al., “Dosing time dependent in vitro pharmacodynamics of Everolimus despite a defective circadian clock,” Cell Cycle, vol. 17, no. 1, pp. 33–42, Jan. 2018, doi: 10.1080/15384101.2017.1387695
-
[54]
“Transport and Adsorption,” COMSOL. https://www.comsol.com/model/transport-and- adsorption-5 (accessed Dec. 31, 2021). Acknowledgements JC would like to acknowledge funding from the Newton Fund—Institutional Links grant (ID 352360246), and Engineering and Physical Sciences Research Council grant EPSRC EP/R00403X/1. We are grateful to Hannah Bridgewater fo...
work page 2021
discussion (0)
Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.