The authors' main claim This paper presents a joint calibration scheme for voltage (V) and current (I) probes that helps resolve accurately voltage-current phase differences even when the difference is very close to $90^{\circ}$.
The compiled record
The paper's own sentences, arranged. Each label is drawn from a closed vocabulary; the number beside it is the probability the classifier gave that label. Numbers in the tables are the authors', checked by code. No sentence in this record was written by a model.
Open the compiled record
The abstract, sentence by sentence
This paper presents a joint calibration scheme for voltage (V) and current (I) probes that helps resolve accurately voltage-current phase differences even when the difference is very close to $90^{\circ}$. The latter has been a major issue with V-I probes when used with miniature RF plasma devices like the atmospheric pressure plasma jet (APPJ). Since the impedance of such miniature devices is predominantly capacitive, the phase difference between the voltage and current signals is very nearly $90^{\circ}$. It turns out, however, that when V-I probes are used with such devices without joint calibration, these frequently yield phase shifts over $90^{\circ}$. Also, since power absorption is proportional to the resistive part of the impedance it becomes very sensitive to the phase difference when it is close to $\approx90^{\circ}$. Thus, it is important to be able to resolve the phases accurately. Post-calibration, V-I probes would be indispensable for the electrical characterization of APPJs for determining average RF power $P_{av}$, plasma impedance $Z_p$, etc.Typical post-calibration V-I data yields, $Zp \approx 93.6 - j 1139 {\Omega} (81.5 - j 1173 {\Omega})$ at $P_{av} \approx 9.8 W$ $(\approx7.7 W)$ for helium (argon) gas.
background contribution method result interpretation main claim
| # | sentence | role | the authors' own work | states the main conclusion | strength |
|---|---|---|---|---|---|
| s0 | This paper presents a joint calibration scheme for voltage (V) and current (I) probes that helps resolve accurately voltage-current phase differences even when the difference is very close to $90^{\circ}$. | contribution 1.00 | 0.87 | 0.59 | asserted 0.97 |
| s1 | The latter has been a major issue with V-I probes when used with miniature RF plasma devices like the atmospheric pressure plasma jet (APPJ). | background 0.89 | 0.10 | 0.04 | asserted 1.00 |
| s2 | Since the impedance of such miniature devices is predominantly capacitive, the phase difference between the voltage and current signals is very nearly $90^{\circ}$. | background 1.00 | 0.18 | 0.03 | asserted 1.00 |
| s3 | It turns out, however, that when V-I probes are used with such devices without joint calibration, these frequently yield phase shifts over $90^{\circ}$. | background 0.74 | 0.59 | 0.05 | asserted 0.91 |
| s4 | Also, since power absorption is proportional to the resistive part of the impedance it becomes very sensitive to the phase difference when it is close to $\approx90^{\circ}$. | background 0.87 | 0.28 | 0.04 | asserted 1.00 |
| s5 | Thus, it is important to be able to resolve the phases accurately. | interpretation 0.56 | 0.11 | 0.11 | asserted 0.99 |
| s6 | Post-calibration, V-I probes would be indispensable for the electrical characterization of APPJs for determining average RF power $P_{av}$, plasma impedance $Z_p$, etc.Typical post-calibration V-I data yields, $Zp \approx 93.6 - j 1139 {\Omega} (81.5 - j 1173 {\Omega})$ at $P_{av} \approx 9.8 W$ $(\approx7.7 W)$ for helium (argon) gas. | result 0.98 | 0.85 | 0.17 | asserted 0.99 |
What was examined, and what was not
- arXiv listing abstract v1
- full text
- figures and tables
- references and citing sentences
- relations to other papers
- P abstract
- S sections
- T body sentences
- C citations
- R cross-paper relations
The paper
Original abstract
This paper presents a joint calibration scheme for voltage (V) and current (I) probes that helps resolve accurately voltage-current phase differences even when the difference is very close to $90^{\circ}$. The latter has been a major issue with V-I probes when used with miniature RF plasma devices like the atmospheric pressure plasma jet (APPJ). Since the impedance of such miniature devices is predominantly capacitive, the phase difference between the voltage and current signals is very nearly $90^{\circ}$. It turns out, however, that when V-I probes are used with such devices without joint calibration, these frequently yield phase shifts over $90^{\circ}$. Also, since power absorption is proportional to the resistive part of the impedance it becomes very sensitive to the phase difference when it is close to $\approx90^{\circ}$. Thus, it is important to be able to resolve the phases accurately. Post-calibration, V-I probes would be indispensable for the electrical characterization of APPJs for determining average RF power $P_{av}$, plasma impedance $Z_p$, etc.Typical post-calibration V-I data yields, $Zp \approx 93.6 - j 1139 {\Omega} (81.5 - j 1173 {\Omega})$ at $P_{av} \approx 9.8 W$ $(\approx7.7 W)$ for helium (argon) gas.
Human review
Discussion
Know something about this paper? Leave a comment, or highlight any passage above to comment on it.