Pith. sign in

REVIEW 3 cited by

The state-of-the-art 3D anisotropic intracranial hemorrhage segmentation on non-contrast head CT: The INSTANCE challenge

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2301.03281 v2 pith:RXQ5WHPK submitted 2023-01-09 eess.IV cs.CV

classification eess.IVcs.CV
keywords segmentationanisotropichemorrhagechallengeinstanceintracranialcasesdifferent
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
read the original abstract

Automatic intracranial hemorrhage segmentation in 3D non-contrast head CT (NCCT) scans is significant in clinical practice. Existing hemorrhage segmentation methods usually ignores the anisotropic nature of the NCCT, and are evaluated on different in-house datasets with distinct metrics, making it highly challenging to improve segmentation performance and perform objective comparisons among different methods. The INSTANCE 2022 was a grand challenge held in conjunction with the 2022 International Conference on Medical Image Computing and Computer Assisted Intervention (MICCAI). It is intended to resolve the above-mentioned problems and promote the development of both intracranial hemorrhage segmentation and anisotropic data processing. The INSTANCE released a training set of 100 cases with ground-truth and a validation set with 30 cases without ground-truth labels that were available to the participants. A held-out testing set with 70 cases is utilized for the final evaluation and ranking. The methods from different participants are ranked based on four metrics, including Dice Similarity Coefficient (DSC), Hausdorff Distance (HD), Relative Volume Difference (RVD) and Normalized Surface Dice (NSD). A total of 13 teams submitted distinct solutions to resolve the challenges, making several baseline models, pre-processing strategies and anisotropic data processing techniques available to future researchers. The winner method achieved an average DSC of 0.6925, demonstrating a significant growth over our proposed baseline method. To the best of our knowledge, the proposed INSTANCE challenge releases the first intracranial hemorrhage segmentation benchmark, and is also the first challenge that intended to resolve the anisotropic problem in 3D medical image segmentation, which provides new alternatives in these research fields.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 3 Pith papers

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. Modality-Projection Universal Model for Comprehensive Full-Body Medical Imaging Segmentation

    eess.IV 2024-12 conditional novelty 6.0 of 10

    MPUM is a multi-modality medical segmentation model whose controller generates per-modality convolution kernels, claiming top Dice scores across CT, MR, and PET and two clinical applications.

  2. SegBook: A Simple Baseline and Cookbook for Volumetric Medical Image Segmentation

    eess.IV 2024-11 conditional novelty 6.0 of 10

    A large-scale evaluation of full-body CT pretrained STU-Net across 87 datasets shows fine-tuning improves segmentation on small and large datasets more than on medium ones, and supports cross-modality and cross-target...

  3. Interactive Medical Image Segmentation: A Benchmark Dataset and Baseline

    cs.CV 2024-11 conditional novelty 6.0 of 10

    IMed-361M, built by combining 110 public and private datasets and adding 273 million machine-generated masks, is released with an interactive segmentation baseline that outperforms existing models on several external ...

Pith tools