Pith. sign in

REVIEW 1 cited by

Multi-instrument Comparative Study of Temperature, Number Density, and Emission Measure during the Precursor Phase of a Solar Flare

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2302.06825 v1 pith:33K3W2X3 submitted 2023-02-14 astro-ph.SR

classification astro-ph.SR
keywords differentgoessolarvariationsdensityemissioneovsanumber
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
read the original abstract

We present a multi-instrument study of the two precursor brightenings prior to the M6.5 flare (SOL2015-06-22T18:23) in the NOAA Active Region 12371, with a focus on the temperature (T), electron number density (n), and emission measure (EM). The data used in this study were obtained from four instruments with a variety of wavelengths, i.e., the Solar Dynamics Observatory's Atmospheric Imaging Assembly (AIA), in six extreme ultraviolet (EUV) passbands; the Expanded Owens Valley Solar Array (EOVSA) in microwave (MW); the Reuven Ramaty High Energy Solar Spectroscopic Imager (RHESSI) in hard X-rays (HXR); and the Geostationary Operational Environmental Satellite (GOES) in soft X-rays (SXR). We compare the temporal variations of T, n, and EM derived from the different data sets. Here are the key results. (1) GOES SXR and AIA EUV have almost identical EM variations (1.5-3x10^48 per cm^3) and very similar T variations, from 8 to 15 million Kelvin (MK). (2) Listed from highest to lowest, EOVSA MW provides the highest temperature variations (15-60 MK), followed by RHESSI HXR (10-24 MK), then GOES SXR and AIA EUV (8-15 MK). (3) The EM variation from the RHESSI HXR measurements is always less than the values from AIA EUV and GOES SXR by at most 20 times. The number density variation from EOVSA MW is greater than the value from AIA EUV by at most 100 times. The results quantitatively describe the differences in the thermal parameters at the precursor phase, as measured by different instruments operating at different wavelength regimes and for different emission mechanisms.

Discussion (0). Sign in to comment.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. Unmasking Synthetic Realities in Generative AI: A Comprehensive Review of Adversarially Robust Deepfake Detection Systems

    cs.CR 2025-07 conditional novelty 3.0 of 10

    A systematic review of deepfake detection finds a pervasive lack of adversarial robustness evaluation across all modalities and calls for resilient, modality-agnostic detectors.

Pith tools