Pith. Sign in

RECORD

Quantitative pulsatility measurements using 3D Dynamic Ultrasound Localization Microscopy

Medical Physics · Submitted 25 Mar 2023

abstract compiled · 2026-09-23 · no language-model review

The authors' main claim Our study provides the first step towards a new biomarker that would allow the detection of dynamic abnormalities in microvessels in the whole brain volume, which could be linked to early signs of neurodegenerative diseases.

how it is stated · hedged possibility 0.93 read the record →

Comment (0) Read on arXiv ↗
Cite ▾
arXiv ID2303.14330 (version 1)
Pith ID5Y7X5TPQ, Pith's permanent record of this paper and its review
CitationBrice Rauby, Chlo\'e Bourquin, Christian Casanova, Fr\'ed\'eric Lesage, Gerardo Ramos-Palacios, Hatim Belgharbi, Hugo Ladret, Jean Provost, Jonathan Por\'ee, Lamyae Ikan, Nelson Cort\'es, Nin Ghigo, Samuel B\'elanger, Vincent Perrot. "Quantitative pulsatility measurements using 3D Dynamic Ultrasound Localization Microscopy." arXiv:2303.14330 (2023). https://pith.science/paper/5Y7X5TPQ
Claim paper

The compiled record

The paper's own sentences, arranged. Each label is drawn from a closed vocabulary; the number beside it is the probability the classifier gave that label. Numbers in the tables are the authors', checked by code. No sentence in this record was written by a model.

Open the compiled record

Compiled by classifier-1.13.0 via TypeSafe API, question bank abstract-p1-20260923, 2026-09-23: 1 request, 5,774 input tokens.

What the abstract itself states, as probabilities: claims first 0.71 · states limitation 0.33 · human participants 0.03 · controlled comparison 0.08 · randomized assignment 0.01 · states quantitative result 0.10 · compares with prior results 0.49 · mentions code or data availability 0.02.

The abstract, sentence by sentence

arXiv listing abstract v1. Results and the main claim are underlined; .

A rise in blood flow velocity variations (i.e., pulsatility) in the brain, caused by the stiffening of upstream arteries, is associated with cognitive impairment and neurodegenerative diseases. The study of this phenomenon requires brain-wide pulsatility measurements, with high penetration depth and high spatiotemporal resolution. The development of Dynamic Ultrasound Localization Microscopy (DULM), based on ULM, has enabled pulsatility measurements in the rodent brain in 2D. However, 2D imaging accesses only one slice of the brain and measures biased velocities due to 2D projection. Herein, we present 3D DULM, which can extract quantitative pulsatility measurements in the cat brain with craniotomy and in the whole mouse brain through the skull, showing a wide range of flow hemodynamics in both large and small vessels. We highlighted a decrease in pulsatility along the vascular tree in the cat brain, and performed an intra-animal validation of the method by showing consistent measurements between the two sides of the Willis circle in the mouse brain. Our study provides the first step towards a new biomarker that would allow the detection of dynamic abnormalities in microvessels in the whole brain volume, which could be linked to early signs of neurodegenerative diseases.

background contribution method result interpretation main claim

What the classifier reports for each sentence. The number is the probability it gave the label.
#sentencerolethe authors' own workstates the main conclusionstrength
s0 A rise in blood flow velocity variations (i.e., pulsatility) in the brain, caused by the stiffening of upstream arteries, is associated with cognitive impairment and neurodegenerative diseases. background 1.00 0.05 0.05 asserted 1.00
s1 The study of this phenomenon requires brain-wide pulsatility measurements, with high penetration depth and high spatiotemporal resolution. background 0.66 0.05 0.03 asserted 0.99
s2 The development of Dynamic Ultrasound Localization Microscopy (DULM), based on ULM, has enabled pulsatility measurements in the rodent brain in 2D. background 0.96 0.21 0.03 asserted 1.00
s3 However, 2D imaging accesses only one slice of the brain and measures biased velocities due to 2D projection. gap 0.90 0.10 0.03 asserted 1.00
s4 Herein, we present 3D DULM, which can extract quantitative pulsatility measurements in the cat brain with craniotomy and in the whole mouse brain through the skull, showing a wide range of flow hemodynamics in both large and small vessels. contribution 0.98 0.96 0.35 asserted 1.00
s5 We highlighted a decrease in pulsatility along the vascular tree in the cat brain, and performed an intra-animal validation of the method by showing consistent measurements between the two sides of the Willis circle in the mouse brain. result 0.99 0.98 0.17 asserted 1.00
s6 Our study provides the first step towards a new biomarker that would allow the detection of dynamic abnormalities in microvessels in the whole brain volume, which could be linked to early signs of neurodegenerative diseases. interpretation 0.65 0.43 0.71 hedged possibility 0.93

What kind of paper the classifier reports this is: method or tool 1.00 · evidence from observation or experiment 1.00.

What was examined, and what was not

sources read
  • arXiv listing abstract v1
not examined
  • full text
  • figures and tables
  • references and citing sentences
  • relations to other papers
levels run
  • P abstract
not run
  • S sections
  • T body sentences
  • C citations
  • R cross-paper relations

Every quoted sentence on this record is the authors'. Every label is from Pith's closed vocabulary, with the probability shown beside it. Every number in the measurements table is the authors', checked by code. Record as JSON

The paper
Original abstract

A rise in blood flow velocity variations (i.e., pulsatility) in the brain, caused by the stiffening of upstream arteries, is associated with cognitive impairment and neurodegenerative diseases. The study of this phenomenon requires brain-wide pulsatility measurements, with high penetration depth and high spatiotemporal resolution. The development of Dynamic Ultrasound Localization Microscopy (DULM), based on ULM, has enabled pulsatility measurements in the rodent brain in 2D. However, 2D imaging accesses only one slice of the brain and measures biased velocities due to 2D projection. Herein, we present 3D DULM, which can extract quantitative pulsatility measurements in the cat brain with craniotomy and in the whole mouse brain through the skull, showing a wide range of flow hemodynamics in both large and small vessels. We highlighted a decrease in pulsatility along the vascular tree in the cat brain, and performed an intra-animal validation of the method by showing consistent measurements between the two sides of the Willis circle in the mouse brain. Our study provides the first step towards a new biomarker that would allow the detection of dynamic abnormalities in microvessels in the whole brain volume, which could be linked to early signs of neurodegenerative diseases.

Human review

Discussion

Know something about this paper? Leave a comment, or highlight any passage above to comment on it.