The authors' main claim We report on the realization of a hemispherical optical cavity with a finesse of F = 13000 sustaining inter-cavity powers of 10 kW, which we operate in a closed-cycle cryostat vacuum system close to 4 Kelvin.

how it is stated · asserted 1.00 read the record →

Comment (0) Read on arXiv ↗
Cite ▾
arXiv ID2304.07508 (version 1)
Pith IDOLSWJR5A, Pith's permanent record of this paper and its review
CitationChristoph Fischer, Henry Fernandes Passagem, Jonathan P. Home, Matt Grau, Oliver Wipfli. "Integration of a high finesse cryogenic build-up cavity with an ion trap." arXiv:2304.07508 (2023). https://pith.science/paper/OLSWJR5A
Claim paper

The compiled record

The paper's own sentences, arranged. Each label is drawn from a closed vocabulary; the number beside it is the probability the classifier gave that label. Numbers in the tables are the authors', checked by code. No sentence in this record was written by a model.

Open the compiled record

Compiled by classifier-1.13.0 via TypeSafe API, question bank abstract-p1-20260923, 2026-09-23: 1 request, 4,915 input tokens.

What the abstract itself states, as probabilities: claims first 0.05 · states limitation 0.59 · human participants 0.02 · controlled comparison 0.03 · randomized assignment 0.01 · states quantitative result 0.99 · compares with prior results 0.06 · mentions code or data availability 0.02.

The abstract, sentence by sentence

arXiv listing abstract v1. Results and the main claim are underlined; .

We report on the realization of a hemispherical optical cavity with a finesse of F = 13000 sustaining inter-cavity powers of 10 kW, which we operate in a closed-cycle cryostat vacuum system close to 4 Kelvin. This was designed and built with an integrated radio-frequency Paul trap, in order to combine optical and radio-frequency trapping. The cavity provides a power build-up factor of 2250. We describe a number of aspects of the system design and operation, including low-vibration mounting and locking including thermal effects at high powers. Thermal self-locking in the high intracavity power regime was observed to enhance the passive stability below 1 kHz. Observations made over repeated cool-downs over a course of a year show a repeatable shift between the ion trap center and the cavity mode.

background contribution method result interpretation main claim

What the classifier reports for each sentence. The number is the probability it gave the label.
#sentencerolethe authors' own workstates the main conclusionstrength
s0 We report on the realization of a hemispherical optical cavity with a finesse of F = 13000 sustaining inter-cavity powers of 10 kW, which we operate in a closed-cycle cryostat vacuum system close to 4 Kelvin. contribution 0.92 0.97 0.33 asserted 1.00
s1 This was designed and built with an integrated radio-frequency Paul trap, in order to combine optical and radio-frequency trapping. contribution 0.50 0.91 0.10 asserted 0.99
s2 The cavity provides a power build-up factor of 2250. result 0.98 0.90 0.10 asserted 1.00
s3 We describe a number of aspects of the system design and operation, including low-vibration mounting and locking including thermal effects at high powers. method 0.66 0.79 0.05 asserted 0.87
s4 Thermal self-locking in the high intracavity power regime was observed to enhance the passive stability below 1 kHz. result 0.98 0.93 0.12 asserted 1.00
s5 Observations made over repeated cool-downs over a course of a year show a repeatable shift between the ion trap center and the cavity mode. result 1.00 0.96 0.12 asserted 1.00

What kind of paper the classifier reports this is: method or tool 0.90 · evidence from observation or experiment 1.00.

What was examined, and what was not

sources read
  • arXiv listing abstract v1
not examined
  • full text
  • figures and tables
  • references and citing sentences
  • relations to other papers
levels run
  • P abstract
not run
  • S sections
  • T body sentences
  • C citations
  • R cross-paper relations

Every quoted sentence on this record is the authors'. Every label is from Pith's closed vocabulary, with the probability shown beside it. Every number in the measurements table is the authors', checked by code. Record as JSON

The paper
Original abstract

We report on the realization of a hemispherical optical cavity with a finesse of F = 13000 sustaining inter-cavity powers of 10 kW, which we operate in a closed-cycle cryostat vacuum system close to 4 Kelvin. This was designed and built with an integrated radio-frequency Paul trap, in order to combine optical and radio-frequency trapping. The cavity provides a power build-up factor of 2250. We describe a number of aspects of the system design and operation, including low-vibration mounting and locking including thermal effects at high powers. Thermal self-locking in the high intracavity power regime was observed to enhance the passive stability below 1 kHz. Observations made over repeated cool-downs over a course of a year show a repeatable shift between the ion trap center and the cavity mode.

Human review

Discussion

Know something about this paper? Leave a comment, or highlight any passage above to comment on it.