Pith. sign in

REVIEW 1 cited by

Accurate Eye Tracking from Dense 3D Surface Reconstructions using Single-Shot Deflectometry

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2308.07298 v3 pith:SPSETQWR submitted 2023-08-14 cs.CV cs.HCphysics.optics

classification cs.CVcs.HCphysics.optics
keywords surfaceaccuratecircmethodsonlysingle-shottrackingcornea
verification ladder T0 review T1 audit T2 compute T3 formal

Signed reviews

No signed human review yet.

0 comments
abstract

Eye-tracking plays a crucial role in the development of virtual reality devices, neuroscience research, and psychology. Despite its significance in numerous applications, achieving an accurate, robust, and fast eye-tracking solution remains a considerable challenge for current state-of-the-art methods. While existing reflection-based techniques (e.g., "glint tracking") are considered to be very accurate, their performance is limited by their reliance on sparse 3D surface data acquired solely from the cornea surface. In this paper, we rethink the way how specular reflections can be used for eye tracking: We propose a novel method for accurate and fast evaluation of the gaze direction that exploits teachings from single-shot phase-measuring-deflectometry(PMD). In contrast to state-of-the-art reflection-based methods, our method acquires dense 3D surface information of both cornea and sclera within only one single camera frame (single-shot). For a typical measurement, we acquire $>3000 \times$ more surface reflection points ("glints") than conventional methods. We show the feasibility of our approach with experimentally evaluated gaze errors on a realistic model eye below only $0.12^\circ$. Moreover, we demonstrate quantitative measurements on real human eyes in vivo, reaching accuracy values between only $0.46^\circ$ and $0.97^\circ$.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. Contact Lens with Moir\'e patterns for High-Precision Eye Tracking

    physics.optics 2025-05 conditional novelty 6.0 of 10

    Two stacked gratings in a contact lens form moiré fringes that shift with viewing angle, giving a measured 0.28 degree resolution for lens orientation from ordinary photographs.

Pith tools