The authors' main claim The obtained data successfully contributed to the study of the pressure separation capability of the PW.

how it is stated · asserted 1.00 read the record →

Comment (0) Read on arXiv ↗
Cite ▾
arXiv ID2308.15825 (version 2)
Pith ID5F4T3HD3, Pith's permanent record of this paper and its review
CitationA. Saito, C. Suzuki, D. Mori, H. Okuno, J. Kono, K. Okuda, K. Tomita, K. Yamasaki, N. Tamura, R. Hamada, R. Suzuki, S. Namba, Y. Kambara, Y. Pan. "Development of the Thomson scattering measurement system for cascade arc device with indirectly heated hollow cathode." arXiv:2308.15825 (2023). https://pith.science/paper/5F4T3HD3
Claim paper

The compiled record

The paper's own sentences, arranged. Each label is drawn from a closed vocabulary; the number beside it is the probability the classifier gave that label. Numbers in the tables are the authors', checked by code. No sentence in this record was written by a model.

Open the compiled record

Compiled by classifier-1.13.0 via TypeSafe API, question bank abstract-p1-20260923, 2026-09-23: 1 request, 7,020 input tokens.

What the abstract itself states, as probabilities: claims first 0.04 · states limitation 0.07 · human participants 0.02 · controlled comparison 0.04 · randomized assignment 0.01 · states quantitative result 0.99 · compares with prior results 0.05 · mentions code or data availability 0.02.

The abstract, sentence by sentence

arXiv listing abstract v2. Results and the main claim are underlined; .

We have developed a Thomson scattering measurement system for the cascade arc discharge device designed for the plasma window (PW) application study. The PW is one of the plasma application techniques that sustain the steep pressure gradient between high pressure (10-100 kPa) and a vacuum environment due to the thermal energy of the plasma. Since the plasma thermal energy is the essential parameter for the pressure separation capability of PW, we installed the Thomson scattering measurement system to observe the electron density and temperature within the anode and cathode of the PW for the detailed analysis of the pressure separation capability. The frequency-doubled Nd:YAG laser (532 nm, 200 mJ, 8 ns) was employed for the probe laser. The scattered light was fed to the triple grating spectrometer. The notch filter between the first and second grating eliminated the stray light, realizing a sufficiently high signal-to-noise ratio. The Thomson scattering measurement system successfully obtained the electron density and temperature of the cascade arc plasma at 20 mm downstream from the tip of the cathode. The installed system successfully obtained the Thomson scattering spectrum and showed that the electron density increased from $2\times10^{19} {\rm m}^{-3}$ to $7\times10^{19} {\rm m}^{-3}$ with the discharge power, while the electron temperature was almost constant at about 2 eV. The obtained data successfully contributed to the study of the pressure separation capability of the PW.

background contribution method result interpretation main claim

What the classifier reports for each sentence. The number is the probability it gave the label.
#sentencerolethe authors' own workstates the main conclusionstrength
s0 We have developed a Thomson scattering measurement system for the cascade arc discharge device designed for the plasma window (PW) application study. contribution 1.00 0.97 0.08 asserted 1.00
s1 The PW is one of the plasma application techniques that sustain the steep pressure gradient between high pressure (10-100 kPa) and a vacuum environment due to the thermal energy of the plasma. background 1.00 0.05 0.03 asserted 1.00
s2 Since the plasma thermal energy is the essential parameter for the pressure separation capability of PW, we installed the Thomson scattering measurement system to observe the electron density and temperature within the anode and cathode of the PW for the detailed analysis of the pressure separation capability. contribution 0.53 0.83 0.07 asserted 0.99
s3 The frequency-doubled Nd:YAG laser (532 nm, 200 mJ, 8 ns) was employed for the probe laser. method 1.00 0.81 0.02 asserted 1.00
s4 The scattered light was fed to the triple grating spectrometer. method 1.00 0.84 0.02 asserted 0.99
s5 The notch filter between the first and second grating eliminated the stray light, realizing a sufficiently high signal-to-noise ratio. method 1.00 0.88 0.03 asserted 1.00
s6 The Thomson scattering measurement system successfully obtained the electron density and temperature of the cascade arc plasma at 20 mm downstream from the tip of the cathode. result 0.88 0.97 0.22 asserted 1.00
s7 The installed system successfully obtained the Thomson scattering spectrum and showed that the electron density increased from $2\times10^{19} {\rm m}^{-3}$ to $7\times10^{19} {\rm m}^{-3}$ with the discharge power, while the electron temperature was almost constant at about 2 eV. result 1.00 0.97 0.48 asserted 1.00
s8 The obtained data successfully contributed to the study of the pressure separation capability of the PW. interpretation 0.71 0.81 0.38 asserted 1.00

What kind of paper the classifier reports this is: method or tool 0.93 · evidence from observation or experiment 1.00.

What was examined, and what was not

sources read
  • arXiv listing abstract v2
not examined
  • full text
  • figures and tables
  • references and citing sentences
  • relations to other papers
levels run
  • P abstract
not run
  • S sections
  • T body sentences
  • C citations
  • R cross-paper relations

Every quoted sentence on this record is the authors'. Every label is from Pith's closed vocabulary, with the probability shown beside it. Every number in the measurements table is the authors', checked by code. Record as JSON

The paper
Original abstract

We have developed a Thomson scattering measurement system for the cascade arc discharge device designed for the plasma window (PW) application study. The PW is one of the plasma application techniques that sustain the steep pressure gradient between high pressure (10-100 kPa) and a vacuum environment due to the thermal energy of the plasma. Since the plasma thermal energy is the essential parameter for the pressure separation capability of PW, we installed the Thomson scattering measurement system to observe the electron density and temperature within the anode and cathode of the PW for the detailed analysis of the pressure separation capability. The frequency-doubled Nd:YAG laser (532 nm, 200 mJ, 8 ns) was employed for the probe laser. The scattered light was fed to the triple grating spectrometer. The notch filter between the first and second grating eliminated the stray light, realizing a sufficiently high signal-to-noise ratio. The Thomson scattering measurement system successfully obtained the electron density and temperature of the cascade arc plasma at 20 mm downstream from the tip of the cathode. The installed system successfully obtained the Thomson scattering spectrum and showed that the electron density increased from $2\times10^{19} {\rm m}^{-3}$ to $7\times10^{19} {\rm m}^{-3}$ with the discharge power, while the electron temperature was almost constant at about 2 eV. The obtained data successfully contributed to the study of the pressure separation capability of the PW.

Human review

Discussion

Know something about this paper? Leave a comment, or highlight any passage above to comment on it.