Pith. sign in

REVIEW 1 cited by

Noise Reduction Methods for Large-scale Intensity-mapping Measurements with Infrared Detector Arrays

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2309.15966 v1 pith:EETCCJQP submitted 2023-09-27 astro-ph.IM

classification astro-ph.IM
keywords noisemethodsamplifierdetectorh2rganalysisangulararrays
verification ladder T0 review T1 audit T2 compute T3 formal

Signed reviews

No signed human review yet.

0 comments
abstract

Intensity mapping observations measure galaxy clustering fluctuations from spectral-spatial maps, requiring stable noise properties on large angular scales. We have developed specialized readouts and analysis methods for achieving large-scale noise stability with Teledyne 2048$\times$2048 H2RG infrared detector arrays. We designed and fabricated a room-temperature low-noise ASIC Video8 amplifier to sample each of the 32 detector outputs continuously in sample-up-the-ramp mode with interleaved measurements of a stable reference voltage that remove current offsets and $1/f$ noise from the amplifier. The amplifier addresses rows in an order different from their physical arrangement on the array, modulating temporal $1/f$ noise in the H2RG to high spatial frequencies. Finally, we remove constant signal offsets in each of the 32 channels using reference pixels. These methods will be employed in the upcoming SPHEREx orbital mission that will carry out intensity mapping observations in near-infrared spectral maps in deep fields located near the ecliptic poles. We also developed a noise model for the H2RG and Video8 to optimize the choice of parameters. Our analysis indicates that these methods hold residual $1/f$ noise near the level of SPHEREx photon noise on angular scales smaller than $\sim30$ arcminutes.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. An Open Source RFSoC-based Readout Electronics System for Arrays of Kinetic Inductance Detectors and Superconducting Resonators

    physics.ins-det 2026-08 conditional novelty 4.0 of 10

    A two-channel RFSoC-based readout system reads up to 2048 kinetic inductance detectors with noise low enough for detector-limited operation on sky.

Pith tools