Pith. Sign in

RECORD

Digital Transformation of High Voltage Isolation Control and Monitoring System for HVE-400 Ion Implanter

Instrumentation and Detectors · Submitted 12 Nov 2023

abstract compiled · 2026-09-23 · no language-model review

The authors' main claim After upgrading, the implanter high-voltage platform control and monitoring system features digitalization, centralized control, high reliability, strong anti-interference, fast communication speed, and easy operation.

how it is stated · asserted 1.00 read the record →

Comment (0) Read on arXiv ↗
Cite ▾
arXiv ID2311.16164 (version 1)
Pith IDHXT5LB5L, Pith's permanent record of this paper and its review
CitationChengbo Li, Chungang Guo, Xiaoming Li, Xuepeng Sun, Zhiguo Liu. "Digital Transformation of High Voltage Isolation Control and Monitoring System for HVE-400 Ion Implanter." arXiv:2311.16164 (2023). https://pith.science/paper/HXT5LB5L
Claim paper

The compiled record

The paper's own sentences, arranged. Each label is drawn from a closed vocabulary; the number beside it is the probability the classifier gave that label. Numbers in the tables are the authors', checked by code. No sentence in this record was written by a model.

Open the compiled record

Compiled by classifier-1.13.0 via TypeSafe API, question bank abstract-p1-20260923, 2026-09-23: 1 request, 5,588 input tokens.

What the abstract itself states, as probabilities: claims first 0.03 · states limitation 0.13 · human participants 0.02 · controlled comparison 0.10 · randomized assignment 0.01 · states quantitative result 0.05 · compares with prior results 0.26 · mentions code or data availability 0.02.

The abstract, sentence by sentence

arXiv listing abstract v1. Results and the main claim are underlined; .

HVE-400 ion implanter is special ion implantation equipment for semiconductor materials boron and phosphorus doping. The ion source and extraction deflection system are at high voltage platform, while the corresponding control system is at ground voltage position. The control signals and measurement signals of various parameters at the high-voltage end need to be transmitted between ground voltage and high voltage through optical fibers to isolate high voltage. Upgrading is carried out due to the aging of the optical fiber transmission control and monitoring system, which cannot work stably. The transformation replaces the original distributed single-point control method with an advanced distributed centralized control method, and integrates all control and monitoring functions into an industrial control computer for digital operation and display. In the computer software, two kinds of automatic calculation of ion mass number are designed. After upgrading, the implanter high-voltage platform control and monitoring system features digitalization, centralized control, high reliability, strong anti-interference, fast communication speed, and easy operation.

background contribution method result interpretation main claim

What the classifier reports for each sentence. The number is the probability it gave the label.
#sentencerolethe authors' own workstates the main conclusionstrength
s0 HVE-400 ion implanter is special ion implantation equipment for semiconductor materials boron and phosphorus doping. background 1.00 0.07 0.02 asserted 1.00
s1 The ion source and extraction deflection system are at high voltage platform, while the corresponding control system is at ground voltage position. background 1.00 0.18 0.02 asserted 1.00
s2 The control signals and measurement signals of various parameters at the high-voltage end need to be transmitted between ground voltage and high voltage through optical fibers to isolate high voltage. background 0.92 0.14 0.04 asserted 1.00
s3 Upgrading is carried out due to the aging of the optical fiber transmission control and monitoring system, which cannot work stably. background 0.93 0.40 0.03 asserted 1.00
s4 The transformation replaces the original distributed single-point control method with an advanced distributed centralized control method, and integrates all control and monitoring functions into an industrial control computer for digital operation and display. method 0.62 0.86 0.21 asserted 1.00
s5 In the computer software, two kinds of automatic calculation of ion mass number are designed. method 0.52 0.85 0.03 asserted 1.00
s6 After upgrading, the implanter high-voltage platform control and monitoring system features digitalization, centralized control, high reliability, strong anti-interference, fast communication speed, and easy operation. result 0.69 0.77 0.81 asserted 1.00

What kind of paper the classifier reports this is: method or tool 1.00 · evidence from argument 0.61.

What was examined, and what was not

sources read
  • arXiv listing abstract v1
not examined
  • full text
  • figures and tables
  • references and citing sentences
  • relations to other papers
levels run
  • P abstract
not run
  • S sections
  • T body sentences
  • C citations
  • R cross-paper relations

Every quoted sentence on this record is the authors'. Every label is from Pith's closed vocabulary, with the probability shown beside it. Every number in the measurements table is the authors', checked by code. Record as JSON

The paper
Original abstract

HVE-400 ion implanter is special ion implantation equipment for semiconductor materials boron and phosphorus doping. The ion source and extraction deflection system are at high voltage platform, while the corresponding control system is at ground voltage position. The control signals and measurement signals of various parameters at the high-voltage end need to be transmitted between ground voltage and high voltage through optical fibers to isolate high voltage. Upgrading is carried out due to the aging of the optical fiber transmission control and monitoring system, which cannot work stably. The transformation replaces the original distributed single-point control method with an advanced distributed centralized control method, and integrates all control and monitoring functions into an industrial control computer for digital operation and display. In the computer software, two kinds of automatic calculation of ion mass number are designed. After upgrading, the implanter high-voltage platform control and monitoring system features digitalization, centralized control, high reliability, strong anti-interference, fast communication speed, and easy operation.

Human review

Discussion

Know something about this paper? Leave a comment, or highlight any passage above to comment on it.