RECORD
Digital Transformation of High Voltage Isolation Control and Monitoring System for HVE-400 Ion Implanter
Instrumentation and Detectors · Submitted 12 Nov 2023
abstract compiled · 2026-09-23 · no language-model review
The authors' main claim After upgrading, the implanter high-voltage platform control and monitoring system features digitalization, centralized control, high reliability, strong anti-interference, fast communication speed, and easy operation.
The compiled record
The paper's own sentences, arranged. Each label is drawn from a closed vocabulary; the number beside it is the probability the classifier gave that label. Numbers in the tables are the authors', checked by code. No sentence in this record was written by a model.
Open the compiled record
The abstract, sentence by sentence
HVE-400 ion implanter is special ion implantation equipment for semiconductor materials boron and phosphorus doping. The ion source and extraction deflection system are at high voltage platform, while the corresponding control system is at ground voltage position. The control signals and measurement signals of various parameters at the high-voltage end need to be transmitted between ground voltage and high voltage through optical fibers to isolate high voltage. Upgrading is carried out due to the aging of the optical fiber transmission control and monitoring system, which cannot work stably. The transformation replaces the original distributed single-point control method with an advanced distributed centralized control method, and integrates all control and monitoring functions into an industrial control computer for digital operation and display. In the computer software, two kinds of automatic calculation of ion mass number are designed. After upgrading, the implanter high-voltage platform control and monitoring system features digitalization, centralized control, high reliability, strong anti-interference, fast communication speed, and easy operation.
background contribution method result interpretation main claim
| # | sentence | role | the authors' own work | states the main conclusion | strength |
|---|---|---|---|---|---|
| s0 | HVE-400 ion implanter is special ion implantation equipment for semiconductor materials boron and phosphorus doping. | background 1.00 | 0.07 | 0.02 | asserted 1.00 |
| s1 | The ion source and extraction deflection system are at high voltage platform, while the corresponding control system is at ground voltage position. | background 1.00 | 0.18 | 0.02 | asserted 1.00 |
| s2 | The control signals and measurement signals of various parameters at the high-voltage end need to be transmitted between ground voltage and high voltage through optical fibers to isolate high voltage. | background 0.92 | 0.14 | 0.04 | asserted 1.00 |
| s3 | Upgrading is carried out due to the aging of the optical fiber transmission control and monitoring system, which cannot work stably. | background 0.93 | 0.40 | 0.03 | asserted 1.00 |
| s4 | The transformation replaces the original distributed single-point control method with an advanced distributed centralized control method, and integrates all control and monitoring functions into an industrial control computer for digital operation and display. | method 0.62 | 0.86 | 0.21 | asserted 1.00 |
| s5 | In the computer software, two kinds of automatic calculation of ion mass number are designed. | method 0.52 | 0.85 | 0.03 | asserted 1.00 |
| s6 | After upgrading, the implanter high-voltage platform control and monitoring system features digitalization, centralized control, high reliability, strong anti-interference, fast communication speed, and easy operation. | result 0.69 | 0.77 | 0.81 | asserted 1.00 |
What was examined, and what was not
- arXiv listing abstract v1
- full text
- figures and tables
- references and citing sentences
- relations to other papers
- P abstract
- S sections
- T body sentences
- C citations
- R cross-paper relations
The paper
Original abstract
HVE-400 ion implanter is special ion implantation equipment for semiconductor materials boron and phosphorus doping. The ion source and extraction deflection system are at high voltage platform, while the corresponding control system is at ground voltage position. The control signals and measurement signals of various parameters at the high-voltage end need to be transmitted between ground voltage and high voltage through optical fibers to isolate high voltage. Upgrading is carried out due to the aging of the optical fiber transmission control and monitoring system, which cannot work stably. The transformation replaces the original distributed single-point control method with an advanced distributed centralized control method, and integrates all control and monitoring functions into an industrial control computer for digital operation and display. In the computer software, two kinds of automatic calculation of ion mass number are designed. After upgrading, the implanter high-voltage platform control and monitoring system features digitalization, centralized control, high reliability, strong anti-interference, fast communication speed, and easy operation.
Human review
Discussion
Know something about this paper? Leave a comment, or highlight any passage above to comment on it.