Polarization and Centre-of-mass Energy Calibration at FCC-ee
Reviewed by Pithpith:23HLIZCAopen to challenge →
read the original abstract
The first stage of the FCC (Future Circular Collider) is a high-luminosity electron-positron collider (FCC-ee) with centre-of-mass energy ranging from 88 to 365 GeV, to study with high precision the Z, W, Higgs and top particles, with samples of $5 \times 10^{12}$ Z bosons, $10^8$ W pairs, $10^6$ Higgs bosons and $10^6$ top quark pairs. A cornerstone of the physics program lays in the precise (ppm) measurements of the W and Z masses and widths, as well as forward-backward asymmetries. To this effect the centre-of-mass energy distribution should be determined with the high precision. This document describes the capacity offered by FCC-ee, starting with transverse polarization of the beams around the Z pole and the W pair threshold. A running scheme based on regular measurements of the beam energy by resonant depolarization of pilot bunches, during physics data taking, is proposed. The design for polarization wigglers, polarimeter and depolarizer is outlined. The $e^\pm$ beam energies will be monitored with a relative precision of $10^{-6}$. The centre-of-mass energy is derived subject to further corrections, related to the beam acceleration, synchrotron radiation and beamstrahlung; these effects are identified and evaluated. Dimuon events $e^+e^- \to \mu^+ \mu^-$, recorded in the detectors, provide with great precision the beam crossing angle, the centre-of-mass energy spread, and the $e^+$ and $e^-$ energy difference. Monitoring methods to minimize absolute error and relative uncertainties are discussed. The impact on the physics measurements is given. A programme of further simulations, design, monitoring and R&D is outlined.
This paper has not been read by Pith yet.
Forward citations
Cited by 3 Pith papers
-
Future Circular Collider Feasibility Study Report: Volume 1, Physics, Experiments, Detectors
The FCC feasibility study describes how a staged electron-positron and hadron collider could deliver precision measurements on the Higgs, electroweak bosons, and top quark while searching for physics beyond the Standa...
-
Status report towards implementation of a Compton polarimeter at BEPCII
Status report on the implementation of a Compton polarimeter at BEPCII, including unambiguous observation of Compton scattering and plans for polarization measurement.
-
Status report towards implementation of a Compton polarimeter at BEPCII
Status report on the design, commissioning through July 2025, and initial observation of Compton interactions in a polarimeter setup at BEPCII.