Pith. Sign in

RECORD

Active Axial Motion Compensation in Multiphoton-Excited Fluorescence Microscopy

Optics · Submitted 19 Jan 2024

abstract compiled · 2026-09-23 · no language-model review

The authors' main claim We demonstrate active motion compensation for non-harmonic axial displacements of the vessel phantom with a field of view up to 400 $\mu$m $\times$ 400 $\mu$m, vertical amplitudes of more than 100 $\mu$m, and at a rate of 0.5 Hz.

how it is stated · asserted 1.00 read the record →

Comment (0) Read on arXiv ↗
Cite ▾
arXiv ID2401.10598 (version 1)
Pith IDU2JAYECH, Pith's permanent record of this paper and its review
CitationBenedikt Wirth, Christian Pilger, Friedemann Kiefer, Manuel Kunisch, Sascha Beutler, Thomas Huser. "Active Axial Motion Compensation in Multiphoton-Excited Fluorescence Microscopy." arXiv:2401.10598 (2024). https://pith.science/paper/U2JAYECH
Claim paper

The compiled record

The paper's own sentences, arranged. Each label is drawn from a closed vocabulary; the number beside it is the probability the classifier gave that label. Numbers in the tables are the authors', checked by code. No sentence in this record was written by a model.

Open the compiled record

Compiled by classifier-1.13.0 via TypeSafe API, question bank abstract-p1-20260923, 2026-09-23: 1 request, 6,275 input tokens.

What the abstract itself states, as probabilities: claims first 0.04 · states limitation 0.20 · human participants 0.07 · controlled comparison 0.05 · randomized assignment 0.01 · states quantitative result 0.98 · compares with prior results 0.06 · mentions code or data availability 0.02.

The abstract, sentence by sentence

arXiv listing abstract v1. Results and the main claim are underlined; .

In living organisms, the natural motion caused by the heartbeat, breathing, or muscle movements leads to the deformation of tissue caused by translation and stretching of the tissue structure. This effect results in the displacement or deformation of the plane of observation for intravital microscopy and causes motion-induced aberrations of the resulting image data. This, in turn, places severe limitations on the time during which specific events can be observed in intravital imaging experiments. These limitations can be overcome if the tissue motion can be compensated such that the plane of observation remains steady. We have developed a mathematical shape space model that can predict the periodic motion of a cylindrical tissue phantom resembling blood vessels. This model is then used to rapidly calculate the future position of the plane of observation of a confocal multiphoton fluorescence microscope. The focal plane is continuously adjusted to the calculated position with a piezo-actuated objective lens holder. We demonstrate active motion compensation for non-harmonic axial displacements of the vessel phantom with a field of view up to 400 $\mu$m $\times$ 400 $\mu$m, vertical amplitudes of more than 100 $\mu$m, and at a rate of 0.5 Hz.

background contribution method result interpretation main claim

What the classifier reports for each sentence. The number is the probability it gave the label.
#sentencerolethe authors' own workstates the main conclusionstrength
s0 In living organisms, the natural motion caused by the heartbeat, breathing, or muscle movements leads to the deformation of tissue caused by translation and stretching of the tissue structure. background 1.00 0.05 0.02 asserted 1.00
s1 This effect results in the displacement or deformation of the plane of observation for intravital microscopy and causes motion-induced aberrations of the resulting image data. background 1.00 0.08 0.03 asserted 1.00
s2 This, in turn, places severe limitations on the time during which specific events can be observed in intravital imaging experiments. background 0.97 0.07 0.03 asserted 1.00
s3 These limitations can be overcome if the tissue motion can be compensated such that the plane of observation remains steady. background 0.73 0.06 0.17 hedged possibility 0.69
s4 We have developed a mathematical shape space model that can predict the periodic motion of a cylindrical tissue phantom resembling blood vessels. method 0.78 0.96 0.07 asserted 1.00
s5 This model is then used to rapidly calculate the future position of the plane of observation of a confocal multiphoton fluorescence microscope. method 0.98 0.90 0.07 asserted 1.00
s6 The focal plane is continuously adjusted to the calculated position with a piezo-actuated objective lens holder. method 1.00 0.93 0.09 asserted 1.00
s7 We demonstrate active motion compensation for non-harmonic axial displacements of the vessel phantom with a field of view up to 400 $\mu$m $\times$ 400 $\mu$m, vertical amplitudes of more than 100 $\mu$m, and at a rate of 0.5 Hz. result 0.91 0.97 0.66 asserted 1.00

What kind of paper the classifier reports this is: method or tool 1.00 · evidence from observation or experiment 0.99.

What was examined, and what was not

sources read
  • arXiv listing abstract v1
not examined
  • full text
  • figures and tables
  • references and citing sentences
  • relations to other papers
levels run
  • P abstract
not run
  • S sections
  • T body sentences
  • C citations
  • R cross-paper relations

Every quoted sentence on this record is the authors'. Every label is from Pith's closed vocabulary, with the probability shown beside it. Every number in the measurements table is the authors', checked by code. Record as JSON

The paper
Original abstract

In living organisms, the natural motion caused by the heartbeat, breathing, or muscle movements leads to the deformation of tissue caused by translation and stretching of the tissue structure. This effect results in the displacement or deformation of the plane of observation for intravital microscopy and causes motion-induced aberrations of the resulting image data. This, in turn, places severe limitations on the time during which specific events can be observed in intravital imaging experiments. These limitations can be overcome if the tissue motion can be compensated such that the plane of observation remains steady. We have developed a mathematical shape space model that can predict the periodic motion of a cylindrical tissue phantom resembling blood vessels. This model is then used to rapidly calculate the future position of the plane of observation of a confocal multiphoton fluorescence microscope. The focal plane is continuously adjusted to the calculated position with a piezo-actuated objective lens holder. We demonstrate active motion compensation for non-harmonic axial displacements of the vessel phantom with a field of view up to 400 $\mu$m $\times$ 400 $\mu$m, vertical amplitudes of more than 100 $\mu$m, and at a rate of 0.5 Hz.

Human review

Discussion

Know something about this paper? Leave a comment, or highlight any passage above to comment on it.