Pith. sign in

REVIEW 1 cited by

RapidVol: Rapid Reconstruction of 3D Ultrasound Volumes from Sensorless 2D Scans

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2404.10766 v1 pith:DUITT5MP submitted 2024-04-16 eess.IV cs.CV

classification eess.IVcs.CV
keywords scansultrasoundneuralreconstructioncross-sectionalhoweverpriorrapidvol
verification ladder T0 review T1 audit T2 compute T3 formal

Signed reviews

No signed human review yet.

0 comments
read the original abstract

Two-dimensional (2D) freehand ultrasonography is one of the most commonly used medical imaging modalities, particularly in obstetrics and gynaecology. However, it only captures 2D cross-sectional views of inherently 3D anatomies, losing valuable contextual information. As an alternative to requiring costly and complex 3D ultrasound scanners, 3D volumes can be constructed from 2D scans using machine learning. However this usually requires long computational time. Here, we propose RapidVol: a neural representation framework to speed up slice-to-volume ultrasound reconstruction. We use tensor-rank decomposition, to decompose the typical 3D volume into sets of tri-planes, and store those instead, as well as a small neural network. A set of 2D ultrasound scans, with their ground truth (or estimated) 3D position and orientation (pose) is all that is required to form a complete 3D reconstruction. Reconstructions are formed from real fetal brain scans, and then evaluated by requesting novel cross-sectional views. When compared to prior approaches based on fully implicit representation (e.g. neural radiance fields), our method is over 3x quicker, 46% more accurate, and if given inaccurate poses is more robust. Further speed-up is also possible by reconstructing from a structural prior rather than from scratch.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. UltraGauss: Ultrafast Gaussian Reconstruction of 3D Ultrasound Volumes

    eess.IV 2025-05 conditional novelty 7.0 of 10

    UltraGauss adapts Gaussian Splatting to ultrasound by evaluating Gaussians at probe-plane intersections instead of projecting them, yielding fast, high-fidelity 3D fetal brain ultrasound reconstructions.

Pith tools