Pith. sign in

REVIEW 1 cited by

Validating a lutetium frequency reference

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2404.16414 v1 pith:YQKSHGOL submitted 2024-04-25 physics.atom-ph quant-ph

classification physics.atom-phquant-ph
keywords frequencyratiotransitionsleftrightarrowtransitioneffectslutetiumonly
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
abstract

We review our progress in developing a frequency reference with singly ionized lutetium and give estimates of the levels of inaccuracy we expect to achieve in the near future with both the $^1S_0\leftrightarrow{}^3D_1$ and $^1S_0\leftrightarrow{}^3D_2$ transitions. Based on established experimental results, we show that inaccuracies at the low $10^{-19}$ level are readily achievable for the $^1S_0\leftrightarrow{}^3D_1$ transition, and the frequency ratio between the two transitions is limited almost entirely by the BBR shift. We argue that the frequency ratio measured within the one apparatus provides a well-defined metric to compare and establish the performance of remotely located systems. For the measurement of an in situ frequency ratio, relativistic shifts drop out and both transitions experience the same electromagnetic environment. Consequently, the uncertainty budget for the ratio is practically identical to the uncertainty budgets for the individual transitions. If the ratios for two or more systems disagree we can be certain at least one of the clock assessments is incorrect. If they agree, subsequent comparisons on one transition would only differ by relativistic effects. Since motional effects are easily assessed and typically small for a heavy ion, only the differential gravitational red-shift will significantly contribute and this can be confirmed by comparison on the second transition.

Discussion (0). Sign in to comment.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. Transportable strontium lattice clock with $4 \times 10^{-19}$ blackbody radiation shift uncertainty

    physics.atom-ph 2025-07 accept novelty 6.0 of 10

    A trailer-mounted 87Sr optical lattice clock reaches a 2.1×10^-18 total systematic uncertainty, with a 4.0×10^-19 blackbody radiation shift uncertainty enabled by a cold copper interrogation shield.

Pith tools