Pith. Sign in

RECORD

DCSM 2.0: Deep Conditional Shape Models for Data Efficient Segmentation

Image and Video Processing · Submitted 28 Jun 2024

abstract compiled · 2026-09-23 · no language-model review

The authors' main claim The method scales well to low data regimes, with gains of up to 5% in dice coefficient, 2.58 mm in average surface distance and 21.02 mm in Hausdorff distance when using just 2% (22 volumes) of the training data.

how it is stated · asserted 1.00 read the record →

Comment (0) Read on arXiv ↗
Cite ▾
arXiv ID2407.00186 (version 1)
Pith IDCHS2YEKW, Pith's permanent record of this paper and its review
CitationAthira J Jacob, Daniel Rueckert, Puneet Sharma. "DCSM 2.0: Deep Conditional Shape Models for Data Efficient Segmentation." arXiv:2407.00186 (2024). https://pith.science/paper/CHS2YEKW
Claim paper

The compiled record

The paper's own sentences, arranged. Each label is drawn from a closed vocabulary; the number beside it is the probability the classifier gave that label. Numbers in the tables are the authors', checked by code. No sentence in this record was written by a model.

Open the compiled record

Compiled by classifier-1.13.0 via TypeSafe API, question bank abstract-p1-20260923, 2026-09-23: 1 request, 5,730 input tokens.

What the abstract itself states, as probabilities: claims first 0.04 · states limitation 0.17 · human participants 0.57 · controlled comparison 0.94 · randomized assignment 0.02 · states quantitative result 0.99 · compares with prior results 0.96 · mentions code or data availability 0.02.

The abstract, sentence by sentence

arXiv listing abstract v1. Results and the main claim are underlined; .

Segmentation is often the first step in many medical image analyses workflows. Deep learning approaches, while giving state-of-the-art accuracies, are data intensive and do not scale well to low data regimes. We introduce Deep Conditional Shape Models 2.0, which uses an edge detector, along with an implicit shape function conditioned on edge maps, to leverage cross-modality shape information. The shape function is trained exclusively on a source domain (contrasted CT) and applied to the target domain of interest (3D echocardiography). We demonstrate data efficiency in the target domain by varying the amounts of training data used in the edge detection stage. We observe that DCSM 2.0 outperforms the baseline at all data levels in terms of Hausdorff distances, and while using 50% or less of the training data in terms of average mesh distance, and at 10% or less of the data with the dice coefficient. The method scales well to low data regimes, with gains of up to 5% in dice coefficient, 2.58 mm in average surface distance and 21.02 mm in Hausdorff distance when using just 2% (22 volumes) of the training data.

background contribution method result interpretation main claim

What the classifier reports for each sentence. The number is the probability it gave the label.
#sentencerolethe authors' own workstates the main conclusionstrength
s0 Segmentation is often the first step in many medical image analyses workflows. background 1.00 0.04 0.01 asserted 0.85
s1 Deep learning approaches, while giving state-of-the-art accuracies, are data intensive and do not scale well to low data regimes. background 0.56 0.07 0.03 asserted 1.00
s2 We introduce Deep Conditional Shape Models 2.0, which uses an edge detector, along with an implicit shape function conditioned on edge maps, to leverage cross-modality shape information. method 0.60 0.85 0.06 asserted 0.99
s3 The shape function is trained exclusively on a source domain (contrasted CT) and applied to the target domain of interest (3D echocardiography). method 0.98 0.83 0.05 asserted 1.00
s4 We demonstrate data efficiency in the target domain by varying the amounts of training data used in the edge detection stage. method 0.73 0.94 0.06 asserted 0.99
s5 We observe that DCSM 2.0 outperforms the baseline at all data levels in terms of Hausdorff distances, and while using 50% or less of the training data in terms of average mesh distance, and at 10% or less of the data with the dice coefficient. result 1.00 0.96 0.56 asserted 1.00
s6 The method scales well to low data regimes, with gains of up to 5% in dice coefficient, 2.58 mm in average surface distance and 21.02 mm in Hausdorff distance when using just 2% (22 volumes) of the training data. result 0.98 0.95 0.55 asserted 1.00

What kind of paper the classifier reports this is: method or tool 1.00 · evidence from observation or experiment 0.96.

What was examined, and what was not

sources read
  • arXiv listing abstract v1
not examined
  • full text
  • figures and tables
  • references and citing sentences
  • relations to other papers
levels run
  • P abstract
not run
  • S sections
  • T body sentences
  • C citations
  • R cross-paper relations

Every quoted sentence on this record is the authors'. Every label is from Pith's closed vocabulary, with the probability shown beside it. Every number in the measurements table is the authors', checked by code. Record as JSON

The paper
Original abstract

Segmentation is often the first step in many medical image analyses workflows. Deep learning approaches, while giving state-of-the-art accuracies, are data intensive and do not scale well to low data regimes. We introduce Deep Conditional Shape Models 2.0, which uses an edge detector, along with an implicit shape function conditioned on edge maps, to leverage cross-modality shape information. The shape function is trained exclusively on a source domain (contrasted CT) and applied to the target domain of interest (3D echocardiography). We demonstrate data efficiency in the target domain by varying the amounts of training data used in the edge detection stage. We observe that DCSM 2.0 outperforms the baseline at all data levels in terms of Hausdorff distances, and while using 50% or less of the training data in terms of average mesh distance, and at 10% or less of the data with the dice coefficient. The method scales well to low data regimes, with gains of up to 5% in dice coefficient, 2.58 mm in average surface distance and 21.02 mm in Hausdorff distance when using just 2% (22 volumes) of the training data.

Human review

Discussion

Know something about this paper? Leave a comment, or highlight any passage above to comment on it.