Pith. sign in

REVIEW 1 cited by

On-sky, real-time optical gain calibration on MagAO-X using incoherent speckles

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2407.13022 v1 pith:HGYWYH4T submitted 2024-07-17 astro-ph.IM

classification astro-ph.IM
keywords gainopticalcalibrationmethodsystemwavefrontdirectextreme
verification ladder T0 review T1 audit T2 compute T3 formal

Signed reviews

No signed human review yet.

0 comments
read the original abstract

The next generation of extreme adaptive optics (AO) must be calibrated exceptionally well to achieve the desired contrast for ground-based direct imaging exoplanet targets. Current wavefront sensing and control system responses deviate from lab calibration throughout the night due to non linearities in the wavefront sensor (WFS) and signal loss. One cause of these changes is the optical gain (OG) effect, which shows that the difference between actual and reconstructed wavefronts is sensitive to residual wavefront errors from partially corrected turbulence. This work details on-sky measurement of optical gain on MagAO-X, an extreme AO system on the Magellan Clay 6.5m. We ultimately plan on using a method of high-temporal frequency probes on our deformable mirror to track optical gain on the Pyramid WFS. The high-temporal frequency probes, used to create PSF copies at 10-22 lambda /D, are already routinely used by our system for coronagraph centering and post-observation calibration. This method is supported by the OG measurements from the modal response, measured simultaneously by sequenced pokes of each mode. When tracked with DIMM measurements, optical gain calibrations show a clear dependence on Strehl Ratio, and this relationship is discussed. This more accurate method of calibration is a crucial next step in enabling higher fidelity correction and post processing techniques for direct imaging ground based systems.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. Comparing realtime optical gain measurement and methods on MagAO-X

    astro-ph.IM 2026-08 conditional novelty 5.0 of 10

    On MagAO-X, incoherent speckle probes can estimate optical gain in real time and roughly track a benchmark measurement, but they underestimate at high gain and the focal-plane Strehl method is unreliable.

Pith tools