Pith. sign in

REVIEW

Benchmarking the design of the cryogenics system for the underground argon in DarkSide-20k

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2408.14071 v2 pith:SFGUAB7F submitted 2024-08-26 physics.ins-det hep-ex

Benchmarking the design of the cryogenics system for the underground argon in DarkSide-20k

DarkSide-20k Collaboration: F. Acerbi , P. Adhikari , P. Agnes , I. Ahmad , S. Albergo , I. F. M. Albuquerque , T. Alexander , A. K. Alton
show 309 more authors
P. Amaudruz M. Angiolilli E. Aprile R. Ardito M. Atzori Corona D. J. Auty M. Ave I. C. Avetisov O. Azzolini H. O. Back Z. Balmforth A. Barrado Olmedo P. Barrillon G. Batignani P. Bhowmick S. Blua V. Bocci W. Bonivento B. Bottino M. G. Boulay A. Buchowicz S. Bussino J. Busto M. Cadeddu M. Cadoni R. Calabrese V. Camillo A. Caminata N. Canci A. Capra M. Caravati M. C\'ardenas-Montes N. Cargioli M. Carlini A. Castellani P. Castello P. Cavalcante S. Cebrian J. Cela Ruiz S. Chashin A. Chepurnov L. Cifarelli D. Cintas M. Citterio B. Cleveland Y. Coadou V. Cocco D. Colaiuda E. Conde Vilda L. Consiglio B. S. Costa M. Czubak M. D'Aniello S. D'Auria M. D. Da Rocha Rolo G. Darbo S. Davini S. De Cecco G. De Guido G. Dellacasa A. V. Derbin A. Devoto F. Di Capua A. Di Ludovico L. Di Noto P. Di Stefano L. K. Dias D. D\'iaz Mairena X. Ding C. Dionisi G. Dolganov F. Dordei V. Dronik A. Elersich E. Ellingwood T. Erjavec M. Fernandez Diaz A. Ficorella G. Fiorillo P. Franchini D. Franco H. Frandini Gatti E. Frolov F. Gabriele D. Gahan C. Galbiati G. Gali\'nski G. Gallina G. Gallus M. Garbini P. Garcia Abia A. Gawdzik A. Gendotti A. Ghisi G. K. Giovanetti V. Goicoechea Casanueva A. Gola L. Grandi G. Grauso G. Grilli di Cortona A. Grobov M. Gromov M. Guerzoni M. Gulino C. Guo B. R. Hackett A. Hallin A. Hamer M. Haranczyk B. Harrop T. Hessel S. Hill S. Horikawa J. Hu F. Hubaut J. Hucker T. Hugues E. V. Hungerford A. Ianni V. Ippolito A. Jamil C. Jillings S. Jois P. Kachru R. Keloth N. Kemmerich A. Kemp C. L. Kendziora M. Kimura A. Kish K. Kondo G. Korga L. Kotsiopoulou S. Koulosousas A. Kubankin P. Kunz\'e M. Kuss M. Ku\'zniak M. Kuzwa M. La Commara M. Lai E. Le Guirriec E. Leason A. Leoni L. Lidey M. Lissia L. Luzzi O. Lychagina O. Macfadyen I. N. Machulin S. Manecki I. Manthos L. Mapelli A. Marasciulli S. M. Mari C. Mariani J. Maricic M. Martinez C. J. Martoff G. Matteucci K. Mavrokoridis A. B. McDonald J. Mclaughlin S. Merzi A. Messina R. Milincic S. Minutoli A. Mitra A. Moharana S. Moioli J. Monroe E. Moretti M. Morrocchi T. Mroz V. N. Muratova M. Murphy M. Murra C. Muscas P. Musico R. Nania M. Nessi G. Nieradka K. Nikolopoulos E. Nikoloudaki J. Nowak K. Olchanski A. Oleinik V. Oleynikov P. Organtini A. Ortiz de Sol\'orzano M. Pallavicini L. Pandola E. Pantic E. Paoloni D. Papi G. Pastuszak G. Paternoster A. Peck P. A. Pegoraro K. Pelczar L. A. Pellegrini R. Perez F. Perotti V. Pesudo S. I. Piacentini N. Pino G. Plante A. Pocar M. Poehlmann S. Pordes P. Pralavorio D. Price S. Puglia M. Queiroga Bazetto F. Ragusa Y. Ramachers A. Ramirez S. Ravinthiran M. Razeti A. L. Renshaw M. Rescigno F. Retiere L. P. Rignanese A. Rivetti A. Roberts C. Roberts G. Rogers L. Romero M. Rossi A. Rubbia D. Rudik M. Sabia P. Salomone O. Samoylov E. Sandford S. Sanfilippo D. Santone R. Santorelli E. M. Santos C. Savarese E. Scapparone G. Schillaci F. G. Schuckman II G. Scioli D. A. Semenov V. Shalamova A. Sheshukov M. Simeone P. Skensved M. D. Skorokhvatov O. Smirnov T. Smirnova B. Smith A. Sotnikov F. Spadoni M. Spangenberg R. Stefanizzi A. Steri V. Stornelli S. Stracka S. Sulis A. Sung C. Sunny Y. Suvorov A. M. Szelc O. Taborda R. Tartaglia A. Taylor J. Taylor S. Tedesco G. Testera K. Thieme A. Thompson T. N. Thorpe A. Tonazzo S. Torres-Lara A. Tricomi E. V. Unzhakov T. J. Vallivilayil M. Van Uffelen L. Velazquez-Fernandez T. Viant S. Viel A. Vishneva R. B. Vogelaar J. Vossebeld B. Vyas M. Wada M. B. Walczak H. Wang Y. Wang S. Westerdale L. Williams R. Wojaczy\'nski M. Wojcik M. M. Wojcik T. Wright X. Xiao Y. Xie C. Yang J. Yin A. Zabihi P. Zakhary A. Zani Y. Zhang T. Zhu A. Zichichi G. Zuzel M. P. Zykova
This is my paper
classification physics.ins-det hep-ex
keywords argondesignsystemcoolingcryogenicsds-20kheatrate
verification ladder T0 review T1 audit T2 compute T3 formal T4 reserved
0 comments
Share X Bluesky LinkedIn Reddit HN
abstract

DarkSide-20k (DS-20k) is a dark matter detection experiment under construction at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy. It utilises ~100 t of low radioactivity argon from an underground source (UAr) in its inner detector, with half serving as target in a dual-phase time projection chamber (TPC). The UAr cryogenics system must maintain stable thermodynamic conditions throughout the experiment's lifetime of over 10 years. Continuous removal of impurities and radon from the UAr is essential for maximising signal yield and mitigating background. We are developing an efficient and powerful cryogenics system with a gas purification loop with a target circulation rate of 1000 slpm. Central to its design is a condenser operated with liquid nitrogen which is paired with a gas heat exchanger cascade, delivering a combined cooling power of more than 8 kW. Here we present the design choices in view of the DS-20k requirements, in particular the condenser's working principle and the cooling control, and we show test results obtained with a dedicated benchmarking platform at CERN and LNGS. We find that the thermal efficiency of the recirculation loop, defined in terms of nitrogen consumption per argon flow rate, is 95 % and the pressure in the test cryostat can be maintained within $\pm$(0.1-0.2) mbar. We further detail a 5-day cool-down procedure of the test cryostat, maintaining a cooling rate typically within -2 K/h, as required for the DS-20k inner detector. Additionally, we assess the circuit's flow resistance, and the heat transfer capabilities of two heat exchanger geometries for argon phase change, used to provide gas for recirculation. We conclude by discussing how our findings influence the finalisation of the system design, including necessary modifications to meet requirements and ongoing testing activities.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.