REVIEW 1 cited by
Ultrafast Proton Delivery with Pin Ridge Filters (pRFs): A Novel Approach for Motion Management in Proton Therapy
Not yet reviewed by Pith; the record is open.
This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.
SPECIMEN: schema-true, not a live event
T0 review · schema-true
One-sentence machine reading of the paper's core claim.
pith:XXXXXXXX · record.json · timestamp
Ultrafast Proton Delivery with Pin Ridge Filters (pRFs): A Novel Approach for Motion Management in Proton Therapy
read the original abstract
Active breath-hold techniques effectively mitigate respiratory motion but pose challenges for patients who are ineligible for the procedure. Conventional treatment planning relies on multiple energy layers, extending delivery time due to slow layer switching. We propose to use pin ridge filters (pRFs), initially developed for FLASH radiotherapy, to construct a single energy beam plan and minimize dose delivery time. The conventional ITV--based free--breathing treatment plan served as the reference. A GTV--based IMPT--DS plan with a downstream energy modulation strategy was developed based on a new beam model that was commissioned using the maximum energy of the IMPT plan. Consequently, a nested iterative pencil beam direction (PBD) spot reduction process removed low--weighted spots along each PBD, generating pRFs with coarser resolution. Finally, the IMPT--DS plan was then converted into an IMPT--pRF plan, using a monoenergetic beam with optimized spot positions and weights. This approach was validated on lung and liver SBRT cases (10 Gy RBE x 5). For the lung case, the mean lung--GTV dose decreased from 10.3 Gy to 6.9 Gy, with delivery time reduced from 188.79 to 36.16 seconds. The largest time reduction was at 150{\deg}, from 47.4 to 3.99 seconds. For the liver case, the mean liver--GTV dose decreased from 5.7 Gy to 3.8 Gy, with delivery time reduced from 111.13 to 30.54 seconds. The largest time reduction was at 180{\deg}, from 38.57 to 3.94 seconds. This method significantly reduces dose delivery time and organ at risk dose. Further analysis is needed to validate its clinical feasibility.
Forward citations
Cited by 1 Pith paper
-
Circulating Lymphocytes Preservation in Lung Cancer Stereotactic Body Radiation Therapy with Ultra-Fast Proton Delivery Using Modularized Pin Ridge Filters
Pin-ridge-filter proton lung SBRT cuts modeled circulating-blood dose and improves modeled lymphocyte survival versus IMPT, mostly by shortening delivery time.
discussion (0)
Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.