Pith. sign in

REVIEW 1 cited by

A Millimeter-Wave Photometric Camera for Long-Range Imaging Through Optical Obscurants Using Kinetic Inductance Detectors

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2502.14607 v1 pith:E7OSGCEM submitted 2025-02-20 astro-ph.IM

classification astro-ph.IM
keywords imagingdetectorinductancekineticopticalskiprarraycamera
verification ladder T0 review T1 audit T2 compute T3 formal

Signed reviews

No signed human review yet.

0 comments
read the original abstract

Passive imaging through optical obscurants is a promising application for mm-wave sensing. We have thus developed the Superconducting Kinetic Inductance Passive Radiometer (SKIPR), a 150 GHz polarization-sensitive photometric camera optimized for terrestrial imaging using a focal plane array with 3,840 kinetic inductance detectors (KIDs). We present a full description of the instrument design, with a particular emphasis on the cryogenic system based on a Gifford-McMahon cryocooler with a two-stage Adiabatic Demagnetization Refrigerator and a dedicated 1.59 m crossed Dragone telescope with an altitude/azimuth mount. We include a detailed lab-based characterization of the KIDs, which results in a determination of their superconducting resonator parameters and optical properties. We also present in situ measurements from the telescope, including point-spread functions and noise characterization. In sum, we find that SKIPR performs as expected, providing diffraction-limited imaging with detector noise performance set by the random arrivals of photons from the ambient background. There is minimal variation in detector characteristics over the full SKIPR focal plane array, and the overall detector yield is 92 per cent.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. An Open Source RFSoC-based Readout Electronics System for Arrays of Kinetic Inductance Detectors and Superconducting Resonators

    physics.ins-det 2026-08 conditional novelty 4.0 of 10

    A two-channel RFSoC-based readout system reads up to 2048 kinetic inductance detectors with noise low enough for detector-limited operation on sky.

Pith tools