REVIEW 3 major objections 6 minor 53 references
Cardiac Digital Twins at Scale from MRI: Open Tools and Representative Models from ~55000 UK Biobank Participants
T0 review · 3 major / 6 minor · reviewed 2026-08-07 · deepseek-v4-flash
Pith's one-line read An automatic pipeline converts cine cardiac MRI into biventricular meshes for over 50,000 UK Biobank participants and releases 1,423 demographic representative meshes with fibers and coordinates.
desk verdict A genuinely useful large-scale resource from an honest pipeline, with a disclosed but unresolved RV wall-thickness assumption that limits but does not sink it. read the letter →
The pith
A machine-rendered reading of the paper's core claim, the machinery that carries it, and where it could break.
The reading
The authors ran this pipeline on about 55,000 UK Biobank participants who had heart MRI. They validated the automatic outlines against expert outlines, reporting Dice scores mostly above 0.88, and compared derived volumes and ejection fractions with previously published values. They then grouped participants by sex, age, and body mass index, and averaged the shapes within each group to create 1,423 representative meshes, which they will release publicly along with the code.
The main caveats are openly stated: the right ventricular wall thickness is fixed at 3 mm for everyone, the mesh-derived volumes run 4-7% below segmentation-derived volumes and mesh-derived left ventricular mass is about 20% higher, and the pre-trained networks and meshes are only promised 'soon', not yet downloadable. The representative meshes are averages, not individual patient models. Even so, the resource would let many research groups run cardiac simulations without rebuilding meshes from scratch.
Extended reading notes
Core claim
The paper's central claim is that an automatic open-source pipeline can generate patient-specific biventricular meshes from cine CMR images at scale, applied to roughly 55,000 UK Biobank participants, producing 1,423 representative meshes that constitute 'the most comprehensive cohort of adult heart models to date' (Abstract). If correct, researchers get open tools and a demographic mesh resource for cardiac digital twin studies.
Load-bearing premise
The pipeline assumes a fixed right ventricular wall thickness of 3 mm for every participant, extending the RV endocardium outward by this amount to create the RV epicardium (Methods, 'Finite element mesh construction'). The authors flag in Limitations that this 'can lead to inaccurate R V function estimation.' If real RV wall thickness varies substantially across the cohort, every released mesh carries an uncontrolled RV geometric bias.
Editorial analysis
A structured set of objections, weighed in public.
Referee Report
Summary. This paper presents an automated pipeline that converts raw short- and long-axis cine CMR images from UK Biobank into biventricular tetrahedral meshes with fibers and universal ventricular coordinates, using nnU-Net segmentation, atlas-based surface reconstruction, and meshtool volume meshing. The pipeline is applied to 54,926 participants, of whom 46,917 pass quality control and contribute to 1,423 demographic-bin representative meshes spanning sex, age, and BMI. The authors validate segmentation Dice scores and derived phenotypes against manual segmentations and previously published values, and report demographic trends (sex differences, age-related decline, BMI-related increase in volumes and mass) that are consistent with the literature.
Significance. The resource is potentially valuable: the code is open source, the pipeline is demonstrated at a scale (>50k) not previously shown for mesh generation, the segmentation validation is technically sound (Dice mostly 0.88–0.98, phenotype errors comparable to prior U-Net work), and the representative meshes with fibers and UVCs would fill a genuine gap in publicly available cardiac digital twin cohorts. The paper is also commendably transparent about its limitations. If the systematic mesh biases and the fixed RV free-wall assumption are addressed or clearly scoped, this could become a standard baseline for population-scale cardiac digital twinning.
major comments (3)
- [Methods, 'Finite element mesh construction'] The RV epicardium is generated by uniformly offsetting the RV endocardium by 3 mm (Methods, 'Finite element mesh construction'; Limitations). This means every biventricular mesh and all 1,423 representative meshes carry a synthetic RV free wall not derived from the participant's images. Because the QC step compares mesh-derived to segmentation-derived volumes and mass, and the segmentations contain no RV epicardium, a uniform offset error is invisible to QC. The authors cite references [42,43] for the 3 mm value but report no sensitivity analysis or external validation of this parameter, and published normal RV free-wall thickness spans roughly 3–5 mm. For a resource intended for electro-mechanical simulations of RV stress, mass, and conduction, this is a load-bearing limitation; please either add a sensitivity analysis over the physiological range of RV wall thickness, validate against a dataset with RV wall measurements, or revise the 'patient-specific' claim to specify that the LV is image-derived while the RV free wall is a fixed-thickness estimate.
- [Table 2] Table 2 shows systematic mesh-versus-segmentation differences: LVEDV −7.7%, LVESV −8.0%, RVEDV −8.0%, RVESV −8.6%, and LV mass +18.6% relative difference (nnUNet–Mesh). The Discussion acknowledges this bias and states it is 'unclear' which phenotype should be preferred, but the bias propagates directly into the representative meshes and the demographic regressions in Fig 4 (e.g., LV mass 133.6±14.8 g for males, above the segmentation-derived values in Table 2). Since the central deliverable is a cohort for quantitative twin studies, the manuscript should either provide a calibration/correction for mesh-derived phenotypes, report which downstream quantities are robust to this bias (e.g., EF appears partly protected), or explicitly flag that representative-mesh phenotypes are not interchangeable with segmentation-derived clinical measurements.
- [Methods, 'Representative mesh generation for different sex, age and BMI groups'] The representative meshes are binned averages with no report of within-bin shape or phenotype variability, and the QC threshold (75th percentile plus 1.5 IQR across three phenotypes) and the minimum bin size of three are arbitrary choices with no sensitivity analysis. For the claim that these 1,423 meshes are 'representative' of demographic groups, please report the within-bin dispersion (e.g., standard deviation or percentiles of volumes and mass) and test whether the demographic trends in Fig 4 persist under alternative QC and binning choices. This would substantiate the representativeness claim and help users understand how much individual variation is lost by averaging.
minor comments (6)
- [Introduction] 'Steady state free precision' should be 'steady-state free precession'.
- [Abstract and Discussion] The Abstract says pre-trained networks and representative meshes 'will be made available soon', while the Discussion states they 'are made publicly available'; please reconcile this and give a concrete availability date or repository status for the meshes, fibers, and trained networks.
- [Table S2 and Methods] Table S2 reports a 'contour quality-control' step that removes 2,377 subjects, but the main text does not describe this QC step; please document it in Methods.
- [Segmentation validation] The LAX segmentation validation uses only 50 test participants; given the importance of LAX landmarks (valve planes, apex) for mesh construction, adding confidence intervals or a comparison on an independent LAX dataset would strengthen the validation.
- [Fig 4] The p-values and regression coefficients in Fig 4 are reported without confidence intervals; adding CIs would improve interpretability of the demographic regressions.
- [Abstract] The abbreviation 'UVC' is used without expansion; please define it at first use.
Circularity Check
No significant circularity: the pipeline is validated against independent manual segmentations and published phenotypes, and the fixed RV wall thickness is an acknowledged external assumption rather than a hidden fit.
full rationale
The paper's derivation chain runs from UK Biobank cine CMR, through nnU-Net segmentation, contour/landmark extraction, atlas-based surface meshing [19], tetrahedral meshing, fiber/UVC assignment, and bin-averaged representative meshes. Each stage is checked against external evidence: segmentation Dice scores against manual segmentations from [29] (Table 1); derived volumes/EFs against manual, nnU-Net, and the independent UNet method of [47] (Tables 2 and 3); and demographic trends of the representative meshes against previously published UK Biobank and external population data [19,30,49]. No claimed prediction is defined in terms of the quantity it is said to predict, and no fitted parameter is relabeled as a result. The only notable modeling choice, a fixed 3 mm RV wall thickness, is explicitly stated in 'Finite element mesh construction' and openly listed as a limitation ('we assumed a fixed 3 mm as the R V wall thickness, that can lead to inaccurate R V function estimation'); it is grounded in external experimental references [42,43], exposed as a configurable pipeline variable, and is not used to generate the validation phenotypes that support the paper's core claims. Self-citations to prior group work (e.g., [19]) are tool citations, not invoked uniqueness theorems, and the current outputs are independently validated in this manuscript. Thus no circular step reaches the threshold required by the review rules.
Assumptions & free parameters
free parameters (4)
- RV wall thickness =
3 mm (fixed)
- Mesh QC outlier threshold =
75th percentile + 1.5 IQR
- Minimum participants per demographic bin =
3
- SAX slices used for ES selection =
5 mid-slices
assumptions (6)
- domain assumption Manual segmentations from [29] are reliable ground truth for training and validation.
- domain assumption The atlas-based mesh construction method [19] produces anatomically valid biventricular surfaces when driven by automatic segmentations at scale.
- domain assumption The fixed 3 mm RV wall thickness is representative for the UKBB cohort.
- domain assumption The first cine frame after R-wave detection corresponds to end-diastole in the UKBB protocol.
- domain assumption Rule-based fiber orientation with alpha from 60 to -60 and beta from -65 to 25 reproduces realistic biventricular fiber architecture.
- domain assumption Procrustes averaging of aligned surface meshes yields a representative 'average heart' for each demographic bin.
Cite this review
Pith. "Pith review of Cardiac Digital Twins at Scale from MRI: Open Tools and Representative Models from ~55000 UK Biobank Participants." pith.science (2026). https://pith.science/paper/HA5M2Y3Q
@misc{pith2026250521019,
author = {Pith},
title = {Pith review of: Cardiac Digital Twins at Scale from MRI: Open Tools and Representative Models from ~55000 UK Biobank Participants},
year = {2026},
howpublished = {\url{https://pith.science/paper/HA5M2Y3Q}},
note = {Machine review of arXiv:2505.21019}
}
abstract
A cardiac digital twin is a virtual replica of a patient's heart for screening, diagnosis, prognosis, risk assessment, and treatment planning of cardiovascular diseases. This requires an anatomically accurate patient-specific 3D structural representation of the heart, suitable for electro-mechanical simulations or study of disease mechanisms. However, generation of cardiac digital twins at scale is demanding and there are no public repositories of models across demographic groups. We describe an automatic open-source pipeline for creating patient-specific left and right ventricular meshes from cardiovascular magnetic resonance images, its application to a large cohort of ~55000 participants from UK Biobank, and the construction of the most comprehensive cohort of adult heart models to date, comprising 1423 representative meshes across sex (male, female), body mass index (range: 16 - 42 kg/m$^2$) and age (range: 49 - 80 years). Our code is available at https://github.com/cdttk/biv-volumetric-meshing/tree/plos2025 , and pre-trained networks, representative volumetric meshes with fibers and UVCs will be made available soon.
Figures
Reference graph
Works this paper leans on
-
[1]
Reducing the Global Burden of Cardiovascular Disease, Part 1
Joseph P, Leong D, McKee M, Anand SS, Schwalm JD, Teo K, et al. Reducing the Global Burden of Cardiovascular Disease, Part 1. Circulation Research. 2017;121(6):677–694. doi:10.1161/CIRCRESAHA.117.308903
-
[2]
The ‘Digital Twin’ to enable the vision of precision cardiology
Corral-Acero J, Margara F, Marciniak M, Rodero C, Loncaric F, Feng Y, et al. The ‘Digital Twin’ to enable the vision of precision cardiology. European Heart Journal. 2020;41(48):4556–4564. doi:10.1093/eurheartj/ehaa159
-
[3]
Coorey G, Figtree GA, Fletcher DF, Snelson VJ, Vernon ST, Winlaw D, et al. The health digital twin to tackle cardiovascular disease—a review of an emerging interdisciplinary field. npj Digital Medicine. 2022;5(1):126. doi:10.1038/s41746-022-00640-7
-
[4]
GPU accelerated digital twins of the human heart open new routes for cardiovascular research
Viola F, Del Corso G, De Paulis R, Verzicco R. GPU accelerated digital twins of the human heart open new routes for cardiovascular research. Scientific Reports. 2023;13(1):8230. doi:10.1038/s41598-023-34098-8
-
[5]
Zaidi H, Jones R, Campos FO, Qian S, Young A, Plank G, et al. MP-470543-006 TOW ARDS A GLOBAL ARRHYTHMIC RISK SCORE FOR ICD PLACEMENT IN ISCHEMIC HEART DISEASE INCORPORATING NOVEL COMPUTATIONAL-DERIVED BIOMARKERS. Heart Rhythm. 2024;21(5):S54–S55. doi:10.1016/j.hrthm.2024.03.369
-
[6]
Qian S, Monaci S, Mendonca-Costa C, Campos F, Gemmell P, Zaidi HA, et al. Additional coils mitigate elevated defibrillation threshold in right-sided implantable cardioverter defibrillator generator placement: a simulation study. EP Europace. 2023;25(6):euad146. doi:10.1093/europace/euad146
-
[7]
Monaci S, Qian S, Gillette K, Puyol-Ant´ on E, Mukherjee R, Elliott MK, et al. Non-invasive localization of post-infarct ventricular tachycardia exit sites to guide ablation planning: a computational deep learning platform utilizing the 12-lead electrocardiogram and intracardiac electrograms from implanted devices. EP Europace. 2022;25(2):469–477. doi:10....
-
[8]
Mauger CA, Gilbert K, Suinesiaputra A, Bluemke DA, Wu CO, Lima JAC, et al. Multi-Ethnic Study of Atherosclerosis: Relationship between Left ventricular shape at cardiac MRI and 10-year outcomes. Radiology. 2023;306(2):e220122
work page 2023
Show all 53 references
-
[9]
Developing Cardiac Digital Twins at Scale: Insights from Personalised Myocardial Conduction Velocity
Qian S, Ugurlu D, Fairweather E, Strocchi M, Toso LD, Deng Y, et al. Developing Cardiac Digital Twins at Scale: Insights from Personalised Myocardial Conduction Velocity. medRxiv. 2024;doi:10.1101/2023.12.05.23299435
2024 doi
-
[10]
Fully Automated, Quality-Controlled Cardiac Analysis From CMR: Validation and Large-Scale Application to Characterize Cardiac Function
Ruijsink B, Puyol-Ant´ on E, Oksuz I, Sinclair M, Bai W, Schnabel JA, et al. Fully Automated, Quality-Controlled Cardiac Analysis From CMR: Validation and Large-Scale Application to Characterize Cardiac Function. JACC: Cardiovascular Imaging. 2020;13(3):684–695
2020
-
[11]
Representation of cardiovascular magnetic resonance in the AHA / ACC guidelines
von Knobelsdorff-Brenkenhoff F, Pilz G, Schulz-Menger J. Representation of cardiovascular magnetic resonance in the AHA / ACC guidelines. Journal of Cardiovascular Magnetic Resonance. 2017;19(1):70
2017
-
[12]
Surface Mesh Reconstruction from Cardiac MRI Contours
Villard B, Grau V, Zacur E. Surface Mesh Reconstruction from Cardiac MRI Contours. Journal of Imaging. 2018;4(1). doi:10.3390/jimaging4010016. September 23, 2025 15/21
2018 doi
-
[13]
A completely automated pipeline for 3D reconstruction of human heart from 2D cine magnetic resonance slices
Banerjee A, Camps J, Zacur E, Andrews CM, Rudy Y, Choudhury RP, et al. A completely automated pipeline for 3D reconstruction of human heart from 2D cine magnetic resonance slices. Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Science...
2021
-
[14]
CINENet: deep learning-based 3D cardiac CINE MRI reconstruction with multi-coil complex-valued 4D spatio-temporal convolutions
K¨ ustner T, Fuin N, Hammernik K, Bustin A, Qi H, Hajhosseiny R, et al. CINENet: deep learning-based 3D cardiac CINE MRI reconstruction with multi-coil complex-valued 4D spatio-temporal convolutions. Scientific Reports. 2020;10(1):13710. doi:10.1038/s41598-020-70551-8
2020 doi
-
[15]
Accelerating cardiac cine MRI using a deep learning-based ESPIRiT reconstruction
Sandino CM, Lai P, Vasanawala SS, Cheng JY. Accelerating cardiac cine MRI using a deep learning-based ESPIRiT reconstruction. Magn Reson Med. 2021;85(1):152–167
2021
-
[16]
Physics-Driven Deep Learning for Computational Magnetic Resonance Imaging: Combining physics and machine learning for improved medical imaging
Hammernik K, K¨ ustner T, Yaman B, Huang Z, Rueckert D, Knoll F, et al. Physics-Driven Deep Learning for Computational Magnetic Resonance Imaging: Combining physics and machine learning for improved medical imaging. IEEE Signal Processing Magazine. 2023;40(1):98–114
2023
-
[17]
An accurate, fast and robust method to generate patient-specific cubic Hermite meshes
Lamata P, Niederer S, Nordsletten D, Barber DC, Roy I, Hose DR, et al. An accurate, fast and robust method to generate patient-specific cubic Hermite meshes. Medical Image Analysis. 2011;15(6):801–813. doi:https://doi.org/10.1016/j.media.2011.06.010
2011 doi
-
[18]
An Iterative Diffeomorphic Algorithm for Registration of Subdivision Surfaces: Application to Congenital Heart Disease
Mauger C, Gilbert K, Suinesiaputra A, Pontr´ e B, Omens J, McCulloch A, et al. An Iterative Diffeomorphic Algorithm for Registration of Subdivision Surfaces: Application to Congenital Heart Disease. In: 2018 40th Annual International Conference of the IEEE Engineering in Medic...
2018
-
[19]
Right ventricular shape and function: cardiovascular magnetic resonance reference morphology and biventricular risk factor morphometrics in UK Biobank
Mauger C, Gilbert K, Lee AM, Sanghvi MM, Aung N, Fung K, et al. Right ventricular shape and function: cardiovascular magnetic resonance reference morphology and biventricular risk factor morphometrics in UK Biobank. Journal of Cardiovascular Magnetic Resonance. 2019;21(1):41
2019
-
[20]
Biventricular Surface Reconstruction From Cine Mri Contours Using Point Completion Networks
Beetz M, Banerjee A, Grau V. Biventricular Surface Reconstruction From Cine Mri Contours Using Point Completion Networks. In: 2021 IEEE 18th International Symposium on Biomedical Imaging (ISBI); 2021. p. 105–109
2021
-
[21]
Automated 3D Whole-Heart Mesh Reconstruction From 2D Cine MR Slices Using Statistical Shape Model
Banerjee A, Zacur E, Choudhury RP, Grau V. Automated 3D Whole-Heart Mesh Reconstruction From 2D Cine MR Slices Using Statistical Shape Model. In: 2022 44th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC); 2022. p. 1702–1706
2022
-
[22]
A high-resolution atlas and statistical model of the human heart from multislice CT
Hoogendoorn C, Duchateau N, S´ anchez-Quintana D, Whitmarsh T, Sukno FM, De Craene M, et al. A high-resolution atlas and statistical model of the human heart from multislice CT. IEEE Trans Med Imaging. 2013;32(1):28–44
2013
-
[23]
Automatic 3D+t four-chamber CMR quantification of the UK biobank: integrating imaging and non-imaging data priors at scale
Xia Y, Chen X, Ravikumar N, Kelly C, Attar R, Aung N, et al. Automatic 3D+t four-chamber CMR quantification of the UK biobank: integrating imaging and non-imaging data priors at scale. Medical Image Analysis. 2022;80:102498. doi:https://doi.org/10.1016/j.media.2022.102498
2022
-
[24]
Linking statistical shape models and simulated function in the healthy adult human heart
Rodero C, Strocchi M, Marciniak M, Longobardi S, Whitaker J, O’Neill MD, et al. Linking statistical shape models and simulated function in the healthy adult human heart. PLoS computational biology. 2021;17(4):e1008851. September 23, 2025 16/21
2021
-
[25]
Multi-view Hybrid Graph Convolutional Network for Volume-to-mesh Reconstruction in Cardiovascular MRI; 2023
Gaggion N, Matheson BA, Xia Y, Bonazzola R, Ravikumar N, Taylor ZA, et al.. Multi-view Hybrid Graph Convolutional Network for Volume-to-mesh Reconstruction in Cardiovascular MRI; 2023
2023
-
[26]
A deep-learning approach for direct whole-heart mesh reconstruction
Kong F, Wilson N, Shadden S. A deep-learning approach for direct whole-heart mesh reconstruction. Medical Image Analysis. 2021;74:102222. doi:https://doi.org/10.1016/j.media.2021.102222
2021
-
[27]
Learning Whole Heart Mesh Generation From Patient Images for Computational Simulations
Kong F, Shadden SC. Learning Whole Heart Mesh Generation From Patient Images for Computational Simulations. IEEE Transactions on Medical Imaging. 2023;42(2):533–545. doi:10.1109/TMI.2022.3219284
2023
-
[28]
UK Biobank: An Open Access Resource for Identifying the Causes of a Wide Range of Complex Diseases of Middle and Old Age
Sudlow C, Gallacher J, Allen N, Beral V, Burton P, Danesh J, et al. UK Biobank: An Open Access Resource for Identifying the Causes of a Wide Range of Complex Diseases of Middle and Old Age. PLoS medicine. 2015;12:e1001779. doi:10.1371/journal.pmed.1001779
2015 doi
-
[29]
Reference ranges for cardiac structure and function using cardiovascular magnetic resonance (CMR) in Caucasians from the UK Biobank population cohort
Petersen SE, Aung N, Sanghvi MM, Zemrak F, Fung K, Paiva JM, et al. Reference ranges for cardiac structure and function using cardiovascular magnetic resonance (CMR) in Caucasians from the UK Biobank population cohort. Journal of Cardiovascular Magnetic Resonance. 2016;19(1):1...
2016 doi
-
[30]
A population-based phenome-wide association study of cardiac and aortic structure and function
Bai W, Suzuki H, Huang J, Francis C, Wang S, Tarroni G, et al. A population-based phenome-wide association study of cardiac and aortic structure and function. Nature medicine. 2020;26(10):1654–1662
2020
-
[31]
Deep Learning for Cardiac Image Segmentation: A Review
Chen C, Qin C, Qiu H, Tarroni G, Duan J, Bai W, et al. Deep Learning for Cardiac Image Segmentation: A Review. Frontiers in Cardiovascular Medicine. 2020;Volume 7 - 2020. doi:10.3389/fcvm.2020.00025
2020
-
[32]
Automatic cardiac cine MRI segmentation and heart disease classification
Ammar A, Bouattane O, Youssfi M. Automatic cardiac cine MRI segmentation and heart disease classification. Computerized Medical Imaging and Graphics. 2021;88:101864. doi:https://doi.org/10.1016/j.compmedimag.2021.101864
2021
-
[33]
Automated segmentation of 3D cine cardiovascular magnetic resonance imaging
Tayebi Arasteh S, Romanowicz J, Pace DF, Golland P, Powell AJ, Maier AK, et al. Automated segmentation of 3D cine cardiovascular magnetic resonance imaging. Frontiers in Cardiovascular Medicine. 2023;10. doi:10.3389/fcvm.2023.1167500
2023
-
[34]
Deep neural network architectures for cardiac image segmentation
El-Taraboulsi J, Cabrera CP, Roney C, Aung N. Deep neural network architectures for cardiac image segmentation. Artificial Intelligence in the Life Sciences. 2023;4:100083. doi:https://doi.org/10.1016/j.ailsci.2023.100083
2023
-
[35]
Advancements in cardiac structures segmentation: a comprehensive systematic review of deep learning in CT imaging
Alnasser TN, Abdulaal L, Maiter A, Sharkey M, Dwivedi K, Salehi M, et al. Advancements in cardiac structures segmentation: a comprehensive systematic review of deep learning in CT imaging. Frontiers in Cardiovascular Medicine. 2024;Volume 11 - 2024. doi:10.3389/fcvm.2024.1323461
2024
-
[36]
nnU-Net: a self-configuring method for deep learning-based biomedical image segmentation
Isensee F, Jaeger PF, Kohl SAA, Petersen J, Maier-Hein KH. nnU-Net: a self-configuring method for deep learning-based biomedical image segmentation. Nature Methods. 2021;18(2):203–211
2021
-
[37]
U-Net: Convolutional Networks for Biomedical Image Segmentation
Ronneberger O, Fischer P, Brox T. U-Net: Convolutional Networks for Biomedical Image Segmentation. In: Medical Image Computing and Computer-Assisted Intervention – MICCAI 2015. Cham: Springer International Publishing; 2015. p. 234–241. September 23, 2025 17/21
2015
-
[38]
Multi-Centre, Multi-Vendor and Multi-Disease Cardiac Segmentation: The M&Ms Challenge
Campello VM, Gkontra P, Izquierdo C, Mart ´ ın-Isla C, Sojoudi A, Full PM, et al. Multi-Centre, Multi-Vendor and Multi-Disease Cardiac Segmentation: The M&Ms Challenge. IEEE Transactions on Medical Imaging. 2021;40(12):3543–3554. doi:10.1109/TMI.2021.3090082
2021
-
[39]
AMOS: A Large-Scale Abdominal Multi-Organ Benchmark for Versatile Medical Image Segmentation; 2022
Ji Y, Bai H, Yang J, Ge C, Zhu Y, Zhang R, et al.. AMOS: A Large-Scale Abdominal Multi-Organ Benchmark for Versatile Medical Image Segmentation; 2022
2022
-
[40]
Deep Learning Segmentation of the Right Ventricle in Cardiac MRI: The M&Ms Challenge
Mart ´ ın-Isla C, Campello VM, Izquierdo C, Kushibar K, Sendra-Balcells C, Gkontra P, et al. Deep Learning Segmentation of the Right Ventricle in Cardiac MRI: The M&Ms Challenge. IEEE Journal of Biomedical and Health Informatics. 2023;27(7):3302–3313. doi:10.1109/JBHI.2023.3267857
2023
-
[41]
Studying Robustness of Semantic Segmentation Under Domain Shift in Cardiac MRI
Full PM, Isensee F, J¨ ager PF, Maier-Hein K. Studying Robustness of Semantic Segmentation Under Domain Shift in Cardiac MRI. In: Puyol Anton E, Pop M, Sermesant M, Campello V, Lalande A, Lekadir K, et al., editors. Statistical Atlases and Computational Models of the Heart. M&...
2021
-
[42]
Echocardiographic measurement of right ventricular wall thickness
Matsukubo H, Matsuura T, Endo N, Asayama J, Watanabe T. Echocardiographic measurement of right ventricular wall thickness. A new application of subxiphoid echocardiography. Circulation. 1977;56(2):278–284
1977
-
[43]
Anatomy, echocardiography, and normal right ventricular dimensions
Ho S, Nihoyannopoulos P. Anatomy, echocardiography, and normal right ventricular dimensions. Heart. 2006;92(suppl 1):i2–i13
2006
-
[44]
Automating image-based mesh generation and manipulation tasks in cardiac modeling workflows using meshtool
Neic A, Gsell MA, Karabelas E, Prassl AJ, Plank G. Automating image-based mesh generation and manipulation tasks in cardiac modeling workflows using meshtool. SoftwareX. 2020;11:100454
2020
-
[45]
Universal ventricular coordinates: A generic framework for describing position within the heart and transferring data
Bayer J, Prassl AJ, Pashaei A, Gomez JF, Frontera A, Neic A, et al. Universal ventricular coordinates: A generic framework for describing position within the heart and transferring data. Medical Image Analysis. 2018;45:83–93. doi:https://doi.org/10.1016/j.media.2018.01.005
2018 doi
-
[46]
A novel rule-based algorithm for assigning myocardial fiber orientation to computational heart models
Bayer JD, Blake RC, Plank G, Trayanova NA. A novel rule-based algorithm for assigning myocardial fiber orientation to computational heart models. Ann Biomed Eng. 2012;40(10):2243–2254
2012
-
[47]
Automated cardiovascular magnetic resonance image analysis with fully convolutional networks
Bai W, Sinclair M, Tarroni G, Oktay O, Rajchl M, Vaillant G, et al. Automated cardiovascular magnetic resonance image analysis with fully convolutional networks. Journal of Cardiovascular Magnetic Resonance. 2018;20(1):65. doi:https://doi.org/10.1186/s12968-018-0471-x
2018 doi
-
[48]
A three-dimensional atlas of child’s cardiac anatomy and the unique morphological alterations associated with obesity
Marciniak M, van Deutekom A W, Toemen L, Lewandowski AJ, Gaillard R, Young AA, et al. A three-dimensional atlas of child’s cardiac anatomy and the unique morphological alterations associated with obesity. European Heart Journal - Cardiovascular Imaging. 2021;23(12):1645–1653. ...
2021 doi
-
[49]
Assessing the causal role of body mass index on cardiovascular health in young adults: Mendelian randomization and recall-by-genotype analyses
Wade KH, Chiesa ST, Hughes AD, Chaturvedi N, Charakida M, Rapala A, et al. Assessing the causal role of body mass index on cardiovascular health in young adults: Mendelian randomization and recall-by-genotype analyses. Circulation. 2018;138(20):2187–2201
2018
-
[50]
A publicly available virtual cohort of four-chamber heart meshes for cardiac electro-mechanics simulations
Strocchi M, Augustin CM, Gsell MA, Karabelas E, Neic A, Gillette K, et al. A publicly available virtual cohort of four-chamber heart meshes for cardiac electro-mechanics simulations. PloS one. 2020;15(6):e0235145. September 23, 2025 18/21
2020
-
[51]
Association of biological age acceleration with cardiac morphology, function, and incident heart failure: insights from UK Biobank participants
Mao R, Wang F, Zhong Y, Meng X, Zhang T, Li J. Association of biological age acceleration with cardiac morphology, function, and incident heart failure: insights from UK Biobank participants. European Heart Journal - Cardiovascular Imaging. 2024;25(9):1315–1323. doi:10.1093/eh...
2024 doi
-
[52]
Estimation of biological heart age using cardiovascular magnetic resonance radiomics
Raisi-Estabragh Z, Salih A, Gkontra P, Atehort´ ua A, Radeva P, Boscolo Galazzo I, et al. Estimation of biological heart age using cardiovascular magnetic resonance radiomics. Scientific Reports. 2022;12(1):12805. doi:10.1038/s41598-022-16639-9
2022 doi
-
[53]
Deep Regression for Biological Age Estimation in Multiple Organs: Investigations on 40,000 Subjects of the UK Biobank
Ecker V, Fr¨ uh M, Yang B, Gatidis S, K¨ ustner T. Deep Regression for Biological Age Estimation in Multiple Organs: Investigations on 40,000 Subjects of the UK Biobank. In: ICASSP 2024 - 2024 IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP); 2...
2024
Reviewed August 7, 2026 · model on record in the stance chip above.