Pith. sign in

REVIEW

MRDust: Wireless Implant Data Uplink & Localization via Magnetic Resonance Image Modulation

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2506.00143 v1 pith:P7TLUMKO submitted 2025-05-30 eess.SY cs.SY

MRDust: Wireless Implant Data Uplink & Localization via Magnetic Resonance Image Modulation

classification eess.SY cs.SY
keywords magneticdataimplantslocalizationmodulationmrdustresonanceactive
verification ladder T0 review T1 audit T2 compute T3 formal T4 reserved
0 comments
Share X Bluesky LinkedIn Reddit HN
abstract

Magnetic resonance imaging (MRI) exhibits rich and clinically useful endogenous contrast mechanisms, which can differentiate soft tissues and are sensitive to flow, diffusion, magnetic susceptibility, blood oxygenation level, and more. However, MRI sensitivity is ultimately constrained by Nuclear Magnetic Resonance (NMR) physics, and its spatiotemporal resolution is limited by SNR and spatial encoding. On the other hand, miniaturized implantable sensors offer highly localized physiological information, yet communication and localization can be challenging when multiple implants are present. This paper introduces the MRDust, an active ``contrast agent" that integrates active sensor implants with MRI, enabling the direct encoding of highly localized physiological data into MR images to augment the anatomical images. MRDust employs a micrometer-scale on-chip coil to actively modulate the local magnetic field, enabling MR signal amplitude and phase modulation for digital data transmission. Since MRI inherently captures the anatomical tissue structure, this method has the potential to enable simultaneous data communication, localization, and image registration with multiple implants. This paper presents the underlying physical principles, design tradeoffs, and design methodology for this approach. To validate the concept, a 900 $\times$ 990 $\mu$m$^2$ chip was designed using TSMC 28 nm technology, with an on-chip coil measuring 630 $\mu$m in diameter. The chip was tested with custom hardware in an MR750W GE3T MRI scanner. Successful voxel amplitude modulation is demonstrated with Spin-Echo Echo-Planar-Imaging (SE-EPI) sequence, achieving a contrast-to-noise ratio (CNR) of 25.58 with a power consumption of 130 $\mu$W.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.