Pith's one-line read Zero-shot BiomedCLIP over-predicts every label on imbalanced chest X-rays, while linear probing recovers most fine-tuning gains at a fraction of the training cost.

desk verdict A useful but under-specified empirical comparison: the zero-shot 'over-predicts all labels' headline is not interpretable because the decision threshold is never stated. read the letter →

arxiv 2506.14136 v1 pith:6N5JBJMX submitted 2025-06-17 cs.CV

classification cs.CV
keywords BiomedCLIPvision-languagemodelszero-shotclassificationlinearprobingfullfine-tuningclassimbalanceout-of-distributionGrad-CAM
verification ladder T0 review T1 audit T2 compute T3 formal

The pith

A machine-rendered reading of the paper's core claim, the machinery that carries it, and where it could break.

The reading

This paper asks whether a large pretrained biomedical vision-language model can classify a highly imbalanced, out-of-distribution radiology dataset, and it answers with a qualified no for zero-shot use. On IU-Xray, zero-shot BiomedCLIP fires on nearly every label, producing low precision, zero exact-match accuracy, and poor inter-class separation. Full fine-tuning reshapes the embedding space and roughly doubles macro-F1, while linear probing recovers most of that gain at less than half the training time and preserves the original spatial fidelity of the model's attention. The paper argues that adaptation strategy, not just model choice, determines whether these models are usable in real clinical settings.

What carries the argument

The argument is carried by the contrastive embedding space of BiomedCLIP and by three measurement tools applied to it. The inter-class versus intra-class Euclidean distance ratio quantifies separability, multi-label metrics (macro-F1, exact-match, LRAP, coverage error) quantify ranking and detection quality, and Grad-CAM heatmaps compare model attention against radiologist-annotated regions. Together they let the paper attribute differences in behavior to the adaptation regime rather than to the dataset or the pretrained weights alone.

What would settle it

Recompute the per-class F1 scores and LRAP on a test set where a radiologist manually labels every image, especially Pneumothorax and Consolidation; if fine-tuning then matches or beats linear probing on mid-frequency classes, the paper's claim that linear probing generalizes better on scarce classes is refuted.

Watch

Extended reading notes

Core claim

The paper's central claim is that BiomedCLIP's zero-shot behavior is systematically over-predictive on imbalanced out-of-distribution radiographs: it assigns labels too liberally, so macro-F1 is 0.105, exact-match accuracy is 0.0%, LRAP is 0.250, and coverage error is 7.70, and the inter/intra-class distance ratio stays at 1.506. Full fine-tuning increases the separation ratio to 1.784 and raises macro-F1 to 0.235, exact-match to 13.4%, and LRAP to 0.779, while linear probing on the frozen encoder reaches 0.183 macro-F1, 4.3% exact-match, and 0.741 LRAP at 6.10 minutes of training versus 15.47 minutes. Per-class, fine-tuning wins on abundant classes and fails on several rare ones, whereas linear probing does better on mid-frequency diseases like Pneumonia, Atelectasis, and Fracture. Grad-CAM comparisons against 15 radiologist annotations show zero-shot heatmaps tightly localized to pathology, fine-tuning heatmaps broad and non-specific, and linear probing retaining near-zero-shot spatial fidelity while adding accuracy.

Load-bearing premise

The comparison assumes the CheXbert-generated labels on IU-Xray reports are accurate enough ground truth for all 14 disease classes, even though CheXbert has roughly 80% validated accuracy and the rarest classes have only 20 to 31 samples.

Editorial extensions

If this is right

  • Zero-shot inference with a biomedical VLM should not be trusted as a clinical classifier on imbalanced out-of-distribution data; its high recall comes at the cost of overwhelming false positives.
  • Linear probing is a viable low-cost adaptation: it recovers most of full fine-tuning's ranking performance and takes less than half the training time.
  • Full fine-tuning is the best choice when abundant classes matter most, but it can erase performance on scarce classes and degrade spatial interpretability.
  • Grad-CAM fidelity and classification accuracy do not move together; zero-shot can localize well while ranking poorly, so interpretability evaluations must be separate from accuracy evaluations.

Reading between the lines

Editorial extensions of the paper, not claims the author makes directly.

  • The same evaluation could be run on a manually labeled out-of-distribution set to test whether the rare-class advantage of linear probing is real or an artifact of label noise.
  • A natural extension is to test prompt-based and adapter-based adaptations, which the paper lists as future work, against the same three heads to see whether the fine-tuning/linear-probing trade-off is specific to full weight updates.
  • The shallow-layer localization result suggests that clinicians may get more useful saliency maps by reading earlier blocks of the encoder, even when the final layer is used for classification.
  • If the zero-shot over-prediction pattern holds on other imbalanced medical datasets, it would argue for defaulting to lightweight probing before deploying any pretrained biomedical VLM in a low-data clinic.
Share X Bluesky LinkedIn Reddit HN

Signed reviews

No signed human review yet.

Editorial analysis

A structured set of objections, weighed in public.

Desk editor's note, referee report, and a circularity audit.

Referee Report

3 major / 6 minor

Summary. The paper evaluates BiomedCLIP on the IU-Xray chest radiograph dataset, which is treated as a highly imbalanced, out-of-distribution, multi-label benchmark. Labels are obtained automatically from radiology reports using CheXbert. The authors compare three adaptation regimes: zero-shot inference, full fine-tuning, and linear probing, reporting embedding-space separability, multi-label classification metrics (macro-F1, exact-match, LRAP, coverage error), and per-label/domain F1. They also present Grad-CAM visualizations compared against 15 radiologist-annotated radiographs. The central claims are that zero-shot BiomedCLIP 'over-predicts all labels' with poor precision and separability, full fine-tuning improves classification of distinct diseases, and linear probing recovers much of the fine-tuning gain at lower cost while preserving spatial fidelity.

Significance. If the quantitative results are taken at face value, the paper provides a useful practical message for users of biomedical VLMs: zero-shot inference on imbalanced OOD radiology data is unreliable, and linear probing is a cost-effective alternative to full fine-tuning. The authors release code and include 15 radiologist-annotated samples for qualitative comparison, which are valuable assets. The embedding-space analysis and the comparison of three adaptation regimes on a realistic imbalanced dataset address a question of genuine interest to the medical imaging community. However, the significance is currently conditional: the headline zero-shot result is threshold-dependent and the manuscript does not specify the decision rule, so the quantitative contrast could be an artifact. The CheXbert labeling and the single train/val/test split further weaken the reliability of per-class comparisons.

major comments (3)
  1. [Section 4.2 and Section 5.1] The paper never specifies the decision rule that converts BiomedCLIP's similarity scores or logits into the binary predictions used in Tables 1 and 2. Section 4.2 (1) states only that zero-shot yields image and text embeddings, and Section 4.3 gives implementation details without any threshold. The claim in the abstract and Section 5.1 that zero-shot 'over-predicts all labels' is precisely a statement about where the positive/negative boundary was placed; a sufficiently low threshold would mechanically predict all 14 labels for every image, producing macro-F1 near 0.105 and LRAP near 0.250 regardless of model quality. The same issue applies to the BCE-trained heads in fine-tuning and linear probing. The authors must specify the threshold for each setting, state how it was chosen (e.g., fixed at 0.5, tuned on validation, or based on a percentile), and ideally supplement the threshold-dependent metrics with threshold-independent ones such as average precision or precision-recall curves. Without this, the central quantitative contrast in Table 1 is uninterpretable.
  2. [Table 1 vs. Section 5.1] There is a direct numerical inconsistency in the reported exact-match accuracy for linear probing. Table 1 lists exact-match as 0.143 (14.3%), while Section 5.1 and the Conclusion state 'exact-match to 4.3%' and 'exact-match = 4.3%', respectively. Since exact-match is one of the headline metrics used to compare the three settings, the authors must correct this inconsistency and verify that all numbers in the text, tables, and abstract are mutually consistent.
  3. [Section 4.3 and Section 6] The quantitative comparison rests on a single train/val/test split (70/10/20) with no repeated runs or confidence intervals, and the ground-truth labels are produced by CheXbert rather than manual review, as the authors acknowledge in the limitations. This is particularly concerning for rare classes such as Pneumothorax (n=20) and Consolidation (n=31), where a handful of mislabeled reports could change per-class F1 values substantially. Claims such as 'linear probing generalizes better on mid-frequency diseases' (Section 5.2) are based on small per-class differences that could be within label-noise or split-induced variation. The authors should report results across multiple seeds or cross-validation folds, provide error bars, and discuss the sensitivity of the reported per-class gaps to CheXbert label noise; a patient-level split should also be used if patients contribute multiple images.
minor comments (6)
  1. [Abstract and Section 5.1] The phrase 'over-predicts all labels' is used as a definitive finding, but without the decision-threshold details it is better framed as a conditional observation; please qualify it until the threshold is specified.
  2. [Introduction] There are several typos: 'Morever' should be 'Moreover'; 'Standford' should be 'Stanford'; 'onewarm-up' should be 'one warm-up'; 'multiperceptron' should be 'multilayer perceptron'.
  3. [References] References [4] and [5] appear to refer to the same Boecking et al. ECCV 2022 paper and are duplicated; please merge or disambiguate.
  4. [Section 5.3] The Grad-CAM discussion would benefit from clearer quantification of 'aligns very closely' and 'co-localized'; consider reporting a quantitative overlap metric (e.g., Dice or IoU) against the radiologist annotations rather than only qualitative descriptions.
  5. [Section 3] The dataset description should mention that IU-Xray contains frontal and lateral views and clarify whether the model is evaluated on both views or only one, since this affects the interpretation of the OOD claim.
  6. [Table 2] The zero-shot F1 scores in Table 2 are all positive even for rare classes; this is surprising given the claim of 'over-predicting all labels' and suggests the threshold may not be extremely low. Clarifying this would help the reader reconcile Table 2 with the headline narrative.

Circularity Check

0 steps flagged · score 0.0 of 10

No circular reasoning: all reported results are empirical evaluations against externally generated labels, not derivations from the paper's own assumptions.

full rationale

The paper's central claims are empirical observations about BiomedCLIP's behavior on IU-Xray: that zero-shot inference over-predicts labels, that full fine-tuning improves macro-F1 and LRAP, and that linear probing recovers most of those gains. These claims are supported by measured metrics (Tables 1-3) computed on model outputs against CheXbert-generated labels, which are external to BiomedCLIP and to the authors' own framework. No parameter is fitted and then renamed as a prediction; no equation is defined in terms of the result it is supposed to explain; and no load-bearing step relies on a self-citation or an imported uniqueness theorem. The authors' adoption of standard adaptation regimes (zero-shot, linear probing, full fine-tuning) and standard multi-label metrics are not circular: they are evaluation protocols, and the paper does not claim to derive model behavior from those protocols. The acknowledged limitation about CheXbert label fidelity and the unspecified threshold or decision rule for converting similarity scores to binary predictions are methodological or reporting concerns, not circularity. The paper is self-contained as an empirical benchmark study, and none of its conclusions reduces to its inputs by construction. Therefore, no circular step is present, and the appropriate score is 0.

Assumptions & free parameters 3 free parameters · 4 assumptions · 0 invented entities

No fitted constants are used to derive the central claim; the listed free parameters are training and labeling choices that affect the quantitative results. The key empirical comparisons rely on CheXbert labels and on unspecified zero-shot thresholding, so the numbers are conditional on those choices.

free parameters (3)
  • zero-shot multi-label threshold = unspecified
    Multi-label zero-shot classification requires a threshold on similarity logits to decide which labels are present; the paper never states this threshold, and exact-match and LRAP results depend on it. It is an implicit free parameter.
  • fine-tuning hyperparameters = not fully reported
    Base learning rate, number of epochs, warm-up duration, and early-stopping patience are chosen by hand or tuned on validation BCE; values are not all reported, making exact results dependent on unstated choices.
  • CheXbert labeler threshold and version = unspecified
    The CheXbert model produces binary labels with a decision threshold; the exact model version and threshold are not specified, affecting all ground-truth labels used in the evaluation.
assumptions (4)
  • domain assumption CheXbert labels are a sufficiently accurate proxy for true disease labels in IU-Xray.
    All F1, LRAP, and exact-match numbers are computed against CheXbert labels; if CheXbert is wrong, the comparison is wrong. Mentioned in Section 3 and limitations in Section 6.
  • domain assumption IU-Xray is out-of-distribution for BiomedCLIP because BiomedCLIP was not pretrained on it.
    The OOD framing rests on this assertion in Section 1; no distribution shift test is provided.
  • domain assumption Euclidean distance in the embedding space reflects semantic class separability.
    Table 1 uses inter/intra-class Euclidean distance ratio as a proxy for class discriminability; this assumes distance structure is meaningful for multi-label chest X-ray categories.
  • domain assumption Grad-CAM activations accurately reflect the model's visual evidence for its predictions.
    Section 5.3 interprets heatmap alignment with radiologist ROIs as evidence of spatial understanding; Grad-CAM is a post-hoc approximation and can be misleading.

how reviews work

0 comments
Cite this review

Pith. "Pith review of Interpreting Biomedical VLMs on High-Imbalance Out-of-Distributions: An Insight into BiomedCLIP on Radiology." pith.science (2026). https://pith.science/paper/6N5JBJMX

@misc{pith2026250614136,
  author       = {Pith},
  title        = {Pith review of: Interpreting Biomedical VLMs on High-Imbalance Out-of-Distributions: An Insight into BiomedCLIP on Radiology},
  year         = {2026},
  howpublished = {\url{https://pith.science/paper/6N5JBJMX}},
  note         = {Machine review of arXiv:2506.14136}
}
read the original abstract

In this paper, we construct two research objectives: i) explore the learned embedding space of BiomedCLIP, an open-source large vision language model, to analyse meaningful class separations, and ii) quantify the limitations of BiomedCLIP when applied to a highly imbalanced, out-of-distribution multi-label medical dataset. We experiment on IU-xray dataset, which exhibits the aforementioned criteria, and evaluate BiomedCLIP in classifying images (radiographs) in three contexts: zero-shot inference, full finetuning, and linear probing. The results show that the model under zero-shot settings over-predicts all labels, leading to poor precision and inter-class separability. Full fine-tuning improves classification of distinct diseases, while linear probing detects overlapping features. We demonstrate visual understanding of the model using Grad-CAM heatmaps and compare with 15 annotations by a radiologist. We highlight the need for careful adaptations of the models to foster reliability and applicability in a real-world setting. The code for the experiments in this work is available and maintained on GitHub.

Figures

Figures reproduced from arXiv: 2506.14136 by the authors.

Figure 1
Figure 1. Quantitative and qualitative evaluation framework for BiomedCLIP under three settings: zero-shot, full finetuning, [PITH_FULL_IMAGE:figures/full_fig_p001_1.png] view at source ↗
Figure 2
Figure 2. Data sample distribution of 14 disease classes of [PITH_FULL_IMAGE:figures/full_fig_p004_2.png] view at source ↗
Figure 3
Figure 3. Grad-CAM visualizations of BiomedCLIP under zero-shot, full fine-tuning, and linear probing adaptations compared [PITH_FULL_IMAGE:figures/full_fig_p006_3.png] view at source ↗

Discussion (0). Continue with ORCID to comment.

Reference graph

Works this paper leans on

30 extracted references · 28 canonical work pages

  1. [1]

    Atmakuru, A., Chakraborty, S., Faust, O., Salvi, M., Barua, P. D., Molinari, F., Acharya, U., and Homaira, N.Deep learning in radiology for lung cancer diagnostics: A systematic review of classification, segmentation, and predictive modeling techniques.Expert Systems with Applications(2024), 124665. BIOKDD’25, August 03–07, 2025, Ontario, Canada Nafiz Sad...

  2. [2]

    K., Rauland, A., Jia, Y., Avval, A

    Azad, R., Aghdam, E. K., Rauland, A., Jia, Y., Avval, A. H., Bozorgpour, A., Karimijafarbigloo, S., Cohen, J. P., Adeli, E., and Merhof, D.Medical image segmentation review: The success of u-net.IEEE Transactions on Pattern Analysis and Machine Intelligence 46(2024), 10076–10095

  3. [3]

    C., Boeck- ing, B., Sharma, H., Bouzid, K., Thieme, A., Schwaighofer, A., Wetscherek, M., Lungren, M

    Bannur, S., Hyland, S., Liu, Q., Pérez-García, F., Ilse, M., Castro, D. C., Boeck- ing, B., Sharma, H., Bouzid, K., Thieme, A., Schwaighofer, A., Wetscherek, M., Lungren, M. P., Nori, A., Alvarez-Valle, J., and Oktay, O.Learning to exploit temporal structure for biomedical vision-language processing. InPro- ceedings of the IEEE/CVF Conference on Computer ...

  4. [4]

    Boecking, B., Usuyama, N., Bannur, S., Castro, D. C., Schwaighofer, A., Hyland, S., Wetscherek, M., Naumann, T., Nori, A., Alvarez-V alle, J., Poon, H., and Oktay, O.Making the most of text semantics to improve biomedical vision–language processing. InComputer Vision – ECCV 2022(Cham, 2022), S. Avidan, G. Brostow, M. Cissé, G. M. Farinella, and T. Hassner...

  5. [5]

    Boecking, B., Usuyama, N., Bannur, S., Castro, D. C., Schwaighofer, A., Hy- land, S., Wetscherek, M., Naumann, T., Nori, A., Alvarez-V alle, J., Poon, H., and Oktay, O.Making the most of text semantics to improve biomedical vision– language processing. InProceedings of the European Conference on Computer Vision (ECCV)(2022), vol. 13696, Springer, pp. 1–21

  6. [6]

    Chambon, P. J. M., Bluethgen, C., Langlotz, C., and Chaudhari, A.Adapting pretrained vision-language foundational models to medical imaging domains. In NeurIPS 2022 Foundation Models for Decision Making Workshop(2022)

  7. [7]

    D., Rosenman, M

    Demner-Fushman, D., Kohli, M. D., Rosenman, M. B., Shooshan, S. E., Ro- driguez, L., Antani, S., Thoma, G. R., and McDonald, C. J.Preparing a col- lection of radiology examinations for distribution and retrieval.Journal of the American Medical Informatics Association 23, 2 (2015), 304–310

  8. [8]

    Dosovitskiy, A.An image is worth 16x16 words: Transformers for image recognition at scale.arXiv preprint arXiv:2010.11929(2020)

Show all 30 references
  1. [9]

    InProceedings of the IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR) (June 2023), pp

    Goyal, S., Kumar, A., Garg, S., Kolter, Z., and Raghunathan, A.Finetune like you pretrain: Improved finetuning of zero-shot vision models. InProceedings of the IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR) (June 2023), pp. 19338–19347

  2. [10]

    Gu, Y., Tinn, R., Cheng, H., Lucas, M., Usuyama, N., Liu, X., Naumann, T., Gao, J., and Poon, H.Domain-specific language model pretraining for biomedical natural language processing.ACM Trans. Comput. Healthcare 3, 1 (2021)

  3. [11]

    P., and Yeung, S.Gloria: A multimodal global-local representation learning framework for label-efficient medical image recognition

    Huang, S.-C., Shen, L., Lungren, M. P., and Yeung, S.Gloria: A multimodal global-local representation learning framework for label-efficient medical image recognition. InProceedings of the IEEE/CVF International Conference on Computer Vision (ICCV)(October 2021), pp. 3942–3951

  4. [12]

    Jing, B., Xie, P., and Xing, E.On the automatic generation of medical imaging reports.arXiv preprint arXiv:1711.08195(2017)

  5. [13]

    Koleilat, T., Asgariandehkordi, H., Rivaz, H., and Xiao, Y.Biomedcoop: Learning to prompt for biomedical vision-language models.arXiv preprint arXiv:2411.15232(2024)

  6. [14]

    J., Young, G., van de Meent, J.-W., and W allace, B

    McInerney, D. J., Young, G., van de Meent, J.-W., and W allace, B. C.That’s the wrong lung! evaluating and improving the interpretability of unsupervised multimodal encoders for medical data. InProceedings of the Conference on Empir- ical Methods in Natural Language Processing...

  7. [15]

    Radford, A., Kim, J. W., Hallacy, C., Ramesh, A., Goh, G., Agarwal, S., Sastry, G., Askell, A., Mishkin, P., Clark, J., Krueger, G., and Sutskever, I.Learning transferable visual models from natural language supervision. InProceedings of the 38th International Conference on Ma...

  8. [16]

    Radford, A., Kim, J. W., Hallacy, C., Ramesh, A., Goh, G., Agarwal, S., Sastry, G., Askell, A., Mishkin, P., Clark, J., Krueger, G., and Sutskever, I.Learning transferable visual models from natural language supervision. InProceedings of the 38th International Conference on Ma...

  9. [17]

    Schäfer, R., Nicke, T., Höfener, H., Lange, A., Merhof, D., Feuerhake, F., Schulz, V., Lotz, J., and Kiessling, F.Overcoming data scarcity in biomedical imaging with a foundational multi-task model.Nature Computational Science 4 (2024), 495–509

  10. [18]

    R., Cogswell, M., Das, A., Vedantam, R., Parikh, D., and Batra, D.Grad-cam: Visual explanations from deep networks via gradient-based local- ization

    Selvaraju, R. R., Cogswell, M., Das, A., Vedantam, R., Parikh, D., and Batra, D.Grad-cam: Visual explanations from deep networks via gradient-based local- ization. InProceedings of the IEEE International Conference on Computer Vision (ICCV)(Oct 2017)

  11. [19]

    R., Gao, M., Lu, L., Xu, Z., Nogues, I., Y ao, J., Mollura, D., and Summers, R

    Shin, H.-C., Roth, H. R., Gao, M., Lu, L., Xu, Z., Nogues, I., Y ao, J., Mollura, D., and Summers, R. M.Deep convolutional neural networks for computer-aided detection: Cnn architectures, dataset characteristics and transfer learning.IEEE transactions on medical imaging 35, 5 ...

  12. [20]

    Sloan, P., Clatworthy, P., Simpson, E., and Mirmehdi, M.Automated radiology report generation: A review of recent advances.IEEE Reviews in Biomedical Engineering 18(2025), 368–387

  13. [21]

    Y., and Lungren, M

    Smit, A., Jain, S., Rajpurkar, P., Pareek, A., Ng, A. Y., and Lungren, M. P. Chexbert: Combining automatic labelers and expert annotations for accurate radiology report labeling using bert, 2020

  14. [22]

    Varoqaux, G., and Cheplygina, V.Machine learning for medical imaging: methodological failures and recommendations for the future.NPJ digital medicine 5, 1 (2022), 48

  15. [23]

    InProceedings of the Conference on Empirical Methods in Natural Language Processing

    W ang, Z., Wu, Z., Agarwal, D., and Sun, J.Medclip: Contrastive learning from unpaired medical images and text. InProceedings of the Conference on Empirical Methods in Natural Language Processing. Conference on Empirical Methods in Natural Language Processing(2022), vol. 2022, p. 3876

  16. [24]

    Wojtara, M., Rana, E., Rahman, T., Khanna, P., and Singh, H.Artificial intelligence in rare disease diagnosis and treatment.Clinical and Translational Science 16, 11 (2023), 2106–2111

  17. [25]

    Zambrano Chaves, J. M., Huang, S.-C., Xu, Y., Xu, H., Usuyama, N., Zhang, S., Wang, F., Xie, Y., Khademi, M., Yang, Z., et al.A clinically accessible small multimodal radiology model and evaluation metric for chest x-ray findings. Nature Communications 16, 1 (2025), 3108

  18. [26]

    R., Badgeley, M

    Zech, J. R., Badgeley, M. A., Liu, M., Costa, A. B., Titano, J. J., and Oermann, E. K.Variable generalization performance of a deep learning model to detect pneumonia in chest radiographs: a cross-sectional study.PLoS medicine 15(2018), e1002683

  19. [27]

    IEEE Transactions on Knowledge and Data Engineering 26, 8 (2014), 1819–1837

    Zhang, M.-L., and Zhou, Z.-H.A review on multi-label learning algorithms. IEEE Transactions on Knowledge and Data Engineering 26, 8 (2014), 1819–1837

  20. [28]

    P., Nau- mann, T., W ang, S., and Poon, H.A multimodal biomedical foundation model trained from fifteen million image–text pairs.NEJM AI 2, 1 (2025), AIoa2400640

    Zhang, S., Xu, Y., Usuyama, N., Xu, H., Bagga, J., Tinn, R., Preston, S., Rao, R., Wei, M., V alluri, N., Wong, C., Tupini, A., W ang, Y., Mazzola, M., Shukla, S., Liden, L., Gao, J., Crabtree, A., Piening, B., Bifulco, C., Lungren, M. P., Nau- mann, T., W ang, S., and Poon, H...

  21. [29]

    Zhang, X., Wu, C., Zhang, Y., Xie, W., and Wang, Y.Knowledge-enhanced visual-language pre-training on chest radiology images.Nature Communications 14, 1 (2023), 4542

  22. [30]

    D., and Langlotz, C

    Zhang, Y., Jiang, H., Miura, Y., Manning, C. D., and Langlotz, C. P.Contrastive learning of medical visual representations from paired images and text. In Proceedings of the 7th Machine Learning for Healthcare Conference(2022), vol. 182, pp. 2–25. Received 20 February 2007; re...

Pith tools

Reviewed August 15, 2026 · model on record in the stance chip above.