Dual frequency calibration to build a portable vapor cell optical clock with improved stability and without a frequency comb
T0 review · 3 major / 6 minor · reviewed 2026-08-06 · deepseek-v4-flash
Pith's one-line read This paper proposes a dual-interferometer vapor-cell clock that calibrates two lasers at once, drops the optical frequency comb, and reaches 1.3 × 10^-15 fractional stability at one second.
desk verdict Clever dual-MZI calibration scheme, but the clock output is a ~73 MHz beat whose fractional stability is ~5e-9, not 1.3e-15; the central claim is contradicted by the paper's own readout. read the letter →
The pith
A machine-rendered reading of the paper's core claim, the machinery that carries it, and where it could break.
The reading
What carries the argument
The load-bearing element is a dual Mach–Zehnder interferometer built around two identical vapor cells, each realizing a double-$\lambda$ (four-level) four-wave-mixing scheme on the $^{87}$Rb D$_2$ line. Classical driving lasers create electromagnetically induced transparency so that weak quantum probe fields pass through the cell; the phase of the transmitted probe field is set by the single-photon detunings $\Delta$ and $\Delta_d$. Because the two interferometers are arranged with the roles of the two frequencies swapped, equality of the two output signals $S$ and $S'$ holds only when $\Delta=\Delta_d$, turning the modulator frequency $\nu_0$ into a controllable variable that the feedback loop re-calibrates. The clock stability then follows from the shot-noise-limited signal-to-noise ratio of the balanced-detection outputs, Eq. (20).
What would settle it
Build the Figure 3 setup with $^{87}$Rb on the D$_2$ line, run the $S=S'$ and $\Delta=\Delta_d\approx0$ feedback loops, and count the beat $\nu-\nu_d$ with a frequency counter; if the measured 1 s Allan deviation of this beat is orders of magnitude above the predicted $1.3\times10^{-15}$, the central timekeeping claim is falsified.
Extended reading notes
Core claim
The central claim is that the dual-interferometer clock reaches standard quantum limited fractional frequency stability $$\frac{\Delta_s}{\nu_d} = \frac{\sqrt{1+$4e^{{-2 l d_{+r}}$}}}{\nu_d\, l\,(d_{+1}+d_{+2})\sqrt{|\bar{E}|^2}} = 1.3\$times10^{{-15}}$\,\sqrt{\mathrm{Hz}^{-1}}$$ (Eq. 20, Fig. 6). The two Mach–Zehnder interferometers, each containing a rubidium vapor cell, generate signals $S$ and $S'$; forcing $S=S'$ locks the two single-photon detunings $\Delta$ and $\Delta_d$ equal, and a second feedback loop then drives both to zero, simultaneously calibrating the two laser frequencies $\nu$ and $\nu_d$ to the $|a\rangle-|b\rangle$ and $|d\rangle-|b\rangle$ transitions. The beat at $\nu-\nu_d = \omega_{ad}$ lies in the radio-frequency range and replaces the optical frequency comb as the timekeeping signal. With Doppler and collisional broadening at 357 K and a 1 kHz laser linewidth, the claimed optimum stability degrades to $3.3\times10^{-15}\,\sqrt{\mathrm{Hz}^{-1}}$ (Fig. 9b).
Load-bearing premise
The clock's timekeeping stability assumes the radio-frequency beat between the two calibrated lasers carries the same fractional stability computed for the optical frequency in Eq. (20), even though the beat frequency is thousands of times smaller than the optical frequency.
Editorial extensions
If this is right
- A portable vapor-cell clock could reach $1.3\times10^{-15}$ at 1 s, roughly an order of magnitude better than the $10^{-13}$ level of current compact two-photon and CPT clocks.
- Removing the optical frequency comb eliminates its femtosecond laser and self-referencing calibration, cutting power and size, which matters for satellite and field deployment.
- The $S=S'$ locking loop also corrects drift or malfunction of the frequency shifter (AOM/EOM/EOFS), because it re-adjusts the modulator frequency to restore $\Delta=\Delta_d$.
- The clock is thermally tolerant: at $T=357\pm5$ K with collisions included, the predicted stability changes only from $1.719\times10^{-15}$ to $1.728\times10^{-15}\sqrt{\mathrm{Hz}^{-1}}$.
- Commercially available 1 kHz-linewidth lasers are sufficient for the $3.3\times10^{-15}$ level, avoiding the need for ultranarrow or cryogenic-stabilized sources.
Reading between the lines
- Editorial: The same dual-interferometer calibration should transfer to other alkali D2 lines or any four-level system with comparable decay rates; testing on Cs would check whether the $S=S'$ condition is as robust as claimed.
- Editorial: The shot-noise scaling $1/\sqrt{|\bar{E}|^2}$ suggests that injecting squeezed light or N00N states into the probe ports could push stability below the standard quantum limit, a path the authors note but do not develop.
- Editorial: The $S=S'$ locking condition is a self-calibrating servo for the frequency shifter, which could find use outside clocks, for example in stabilizing modulators in spectroscopy or lidar systems.
- Editorial: Counting the radio-frequency beat directly makes the clock's long-term accuracy hinge on the absolute value of the excited-state hyperfine splitting $\omega_{ad}$; the paper gives stability but not an accuracy budget, so an absolute-frequency measurement of the beat would be a natural next experiment.
Signed reviews
Editorial analysis
A structured set of objections, weighed in public.
Referee Report
Summary. The manuscript proposes a dual Mach-Zehnder interferometer scheme using a double-lambda system in a hot 87Rb vapor cell to simultaneously calibrate two laser frequencies via electromagnetically induced transparency / four-wave mixing. The two calibrated lasers are then heterodyned to produce a radio-frequency beat at ν−νd = ω_ad, which is counted for timekeeping, eliminating the need for an optical frequency comb. The authors derive a standard-quantum-limited fractional frequency stability Δs/νd = 1.3×10^-15 sqrt(Hz^-1) at the optical frequency, worsening to 3.3×10^-15 sqrt(Hz^-1) after Doppler, collisional, and laser-linewidth broadening.
Significance. If the central claim were correct, the paper would be a substantial advance: a compact, comb-free vapor-cell clock with 1e-15 fractional stability would be significant for portable and space-based clocks. The manuscript contains a detailed quantum Langevin treatment, analytic expressions for the signal and noise, and numerical parameter scans; the explicit treatment of Doppler, collisional, and linewidth broadening is also a strength. However, as detailed in the major comments, the timekeeping readout is inconsistent with the claimed stability, so the significance as stated is not realized.
major comments (3)
- [Section III E and Eq. (20)] The headline stability Δs/νd = 1.3e-15 sqrt(Hz^-1) in Eq. (20) is computed at the optical frequency νd/2π = 3.84e14 Hz, but the clock output actually counted for timekeeping is the beat ν−νd = ω_ad, described in Section III E as a radio-frequency signal (about 72.9 MHz for the 5P3/2 F=0–F=1 interval). A frequency error δν in either calibrated optical field appears directly as the same absolute error in the beat; therefore the fractional stability of the counted beat is δν/ω_ad = (δν/νd)(νd/ω_ad). Using the paper's optimum δν/νd = 1.3e-15 sqrt(Hz^-1) and νd/ω_ad ≈ 5.3e6 gives approximately 6.9e-9 sqrt(Hz^-1), not 1.3e-15. The statement in Section V that the stability "is determined by laser frequency νd and not by radio frequency ν−νd" is not valid for a heterodyne beat: subtracting two optical frequencies does not divide them, and an electronic divider applied after the beat would only multiply the fractional error by the division factor. Since the elimination of the OFC rests on this beat being the timekeeping output, the central claim of the paper is unsupported.
- [Section III C and Section V] The calibration principle relies on the equality S = S' to enforce Δ = Δd. The derivation assumes identical vapor cells: same length l, atomic density N, coupling constant gc, decay rates, and Rabi frequency (γ = γd, |Ē|^2 = |Ē'|^2). In Section V the authors state that MZI-2 need not be identical and that similar classical properties suffice, but no quantitative analysis is given for the effect of unequal cell length, density, or field intensity on the relation S = S' ⇔ Δ = Δd. If the two cells differ, the equality of signals does not imply equality of detunings, and the proposed simultaneous calibration acquires a systematic offset. This is load-bearing for the calibration method and should be analyzed explicitly.
- [Section III E] The timekeeping procedure described in Section III E is to count the oscillations of the 72.9 MHz beat signal. A simple one-second count of a 72.9 MHz signal has a quantization-limited fractional resolution of about 1.4e-8, far above the claimed 1.3e-15 stability. Even if a phase-tracking or interpolating counter is intended, the manuscript does not describe how the radio-frequency readout can achieve a fractional resolution of 1e-15, and the stability of the beat itself is limited by the heterodyne issue in the first comment.
minor comments (6)
- [Section III D] The simplified picture is stated to be valid for |Ω|^2 >> γ^2, but the optimum condition 4|Ω|^2 = κγ_bc l is later used; the consistency of this condition with the strong-drive approximation should be stated more explicitly.
- [Eq. (25) and Eq. (26)] The notation d±D for the Doppler-broadened coefficients is easily confused with a differential; consider renaming the broadened coefficients (e.g., d±,th) to improve readability.
- [Section V] Section V contains malformed state kets, e.g., "⟩d′−⟩b′" and "⟩a−⟩b", which should read |d′⟩−|b′⟩ and |a⟩−|b⟩.
- [Figure 6] The caption of Figure 6 appears truncated ("Δopt/νd 10"); the axis label and units should be given in full.
- [References] Reference [4] is listed as "Demo Journal"; this is not a recognized journal and the citation should be verified or replaced.
- [Abstract] The stability unit appears inconsistently as sqrt(Hz^-1) and Hz^-1/2; one notation should be used throughout.
Circularity Check
No circular reduction found: the stability estimate is a parameterized calculation from stated physical inputs, not a fit or self-citation chain; the only self-citation is a minor non-load-bearing aside.
full rationale
Walking the derivation chain: Eq. (16) and Eq. (19) give each Mach-Zehnder interferometer's signal and noise from the Heisenberg-Langevin equations, and Eq. (20) is the resulting SNR=1 sensitivity divided by nu_d. Equations (23)-(24) follow by explicit algebraic substitution of the stated optimum condition 4|Omega|^2 = kappa*gamma_bc*l, with the numerical 1.3e-15 obtained from stated Rb D2 parameters (gamma/2pi = 6.06 MHz, nu_d/2pi = 3.84e14 Hz, |Ebar|^2/2 = 2.13e15 Hz, cell geometry, number density). The target stability is therefore not fitted into the calculation, and the result is not a renamed input. The dual-interferometer locking condition S = S' <=> Delta = Delta_d is a derived consequence of the symmetry d+r = d'+r and d+j = d'+j under gamma ~ gamma_d, not an ansatz imported from a self-citation. The only self-citation is Ref. [51], used in a speculative aside about non-classical states, which is not load-bearing for Eq. (20). The reader-flagged beat issue is real but is not circularity: Section III E uses the counted beat nu - nu_d = omega_ad for timekeeping whereas Eq. (20) normalizes by nu_d, so the claimed fractional stability does not apply directly to the counted beat; this is a frequency-division denominator mismatch and a correctness risk, not a reduction of the prediction to its own inputs. Score 2 reflects only the minor non-load-bearing self-citation; there is no self-definitional, fitted-input, or self-citation-chain circularity.
Assumptions & free parameters
free parameters (6)
- gamma_bc = gamma_da = 10^-3 gamma =
about 3.8e4 s^-1
- Drive Rabi frequency Omega =
Optimized via 4|Omega|^2 = kappa gamma_bc l
- Cell length l and atom density N =
l = 0.11 m, N = 2e18 m^-3
- Probe beam intensity |Ebar|^2/2 =
2.13e15 Hz, corresponding to 0.54 mW
- Collisional pumping rate gamma_cl =
gamma_cl = gamma_bc
- Laser linewidth zeta =
1 kHz for the final broadened figure
assumptions (6)
- standard math Heisenberg-Langevin formalism with Markovian reservoirs
- standard math Rotating wave approximation and weak-field first-order perturbation
- domain assumption Ground sublevels |b> and |c> are degenerate with no magnetic field
- ad hoc to paper The two vapor cells have identical l, N, g_c, and gamma = gamma_d
- ad hoc to paper A radio-frequency difference beat nu - nu_d can serve as the clock output with optical fractional stability
- domain assumption Doppler shifts cancel for co-propagating double-lambda fields
Cite this review
Pith. "Pith review of Dual frequency calibration to build a portable vapor cell optical clock with improved stability and without a frequency comb." pith.science (2026). https://pith.science/paper/D4VHLBBZ
@misc{pith2026250704911,
author = {Pith},
title = {Pith review of: Dual frequency calibration to build a portable vapor cell optical clock with improved stability and without a frequency comb},
year = {2026},
howpublished = {\url{https://pith.science/paper/D4VHLBBZ}},
note = {Machine review of arXiv:2507.04911}
}
abstract
This article theoretically proposes a new dual interferometer technique to accurately calibrate two laser frequencies simultaneously using four-wave mixing in an alkali metal vapor cell. The two frequency-calibrated lasers are mixed to create a beat signal at radio frequency to build a portable optical atomic clock (OAC) without an optical frequency comb (OFC). Removal of the OFC improves the portability of OAC, while the dual interferometer setup enhances the one second stability to $1.3\times 10^{-15}$, which is better than the current portable OAC. Thermal noise in the OAC is minimized by choosing the double-lambda atomic scheme with co-propagating laser fields. Using D2 transition of Rb-87, the standard quantum limited frequency sensitivity and stability of the OAC are estimated as $3.2\;\sqrt{\mbox{Hz}}$, and $1.3\times10^{-15}\sqrt{\mbox{Hz}^{-1}}$, respectively. After considering broadening effects due to $357\,$K temperature and collisions, the optimum stability of the OAC is reduced to $3.3\times10^{-15}\sqrt{\mbox{Hz}^{-1}}$ for a laser with $1\,$KHz linewidth and $0.54$ mW power at the input of the vapor cell.
Figures
Figures from the paper (8 more)
Reference graph
Works this paper leans on
-
[1]
A. D. Ludlow, M. M. Boyd, J. Ye, E. Peik, and P. O. Schmidt, Optical atomic clocks, Rev. Mod. Phys.87, 637 (2015)
2015
-
[2]
Assuming the quantum fields are weak, they are treated perturbatively up to first order (represented by the superscript ‘(1)’) in Eq. (3). In this work, we further assume an undepleted drive approximation. The output quantum fields from the vapor cell are determined by the atomic operators ˆσ (1) ba and ˆσ (1) ca . The dynamics of ˆσxy can be obtained fro...
-
[3]
All the primed variables have the same meaning as the unprimed variables but for the atom-laser interaction shown in Figure. 2. We further assumed that the sample length l, atomic number density, and coupling constant gc are same in Figure. 1 and Figure. 2. III. CLOCK DESIGN FIG. 3: Schematics of the optical atomic clock. Vapor cell VC1 (VC2) containing R...
-
[4]
N. Poli, C. W. Oates, P. Gill, and G. M. Tino, Optical atomic clocks, La Rivista del Nuovo Cimento 36, 555 (2013)
work page 2013
-
[5]
J. D. Roslund, A. Cing ¨oz, W. D. Lunden, G. B. Partridge, A. S. Kowligy, F. Roller, D. B. Sheredy, G. E. Skulason, J. P. Song, J. R. Abo-Shaeer, and M. M. Boyd, Optical clocks at sea, Nature 628, 736 (2024)
work page 2024
-
[6]
T. N. Bandi, A comprehensive overview of atomic clocks and their applications, Demo Journal 1, 40 (2024)
work page 2024
-
[7]
Schioppo, R
M. Schioppo, R. C. Brown, W. F. McGrew, N. Hinkley, R. J. Fasano, K. Beloy, T. H. Yoon, G. Milani, D. Nicolodi, J. A. Sherman, N. B. Phillips, C. W. Oates, and A. D. Ludlow, Ultrastable optical clock with two cold-atom ensembles, Nature Photonics11, 48 (2017)
2017
-
[8]
T. Bothwell, D. Kedar, E. Oelker, J. M. Robinson, S. L. Bromley, W. L. Tew, J. Ye, and C. J. Kennedy, Jila sri optical lattice clock with uncertainty of 2.0 ×10−18, Metrologia 56, 065004 (2019)
work page 2019
Show all 66 references
-
[9]
W. F. McGrew, X. Zhang, R. J. Fasano, S. A. Sch ¨affer, K. Beloy, D. Nicolodi, R. C. Brown, N. Hinkley, G. Milani, M. Schioppo, T. H. Yoon, and A. D. Ludlow, Atomic clock performance enabling geodesy below the centimetre level, Nature564, 87 (2018)
2018
-
[10]
S. M. Brewer, J.-S. Chen, A. M. Hankin, E. R. Clements, C. W. Chou, D. J. Wineland, D. B. Hume, and D. R. Leibrandt,27al+ quantum- logic clock with a systematic uncertainty below 10−18, Phys. Rev. Lett. 123, 033201 (2019)
2019
-
[11]
Derevianko, V
A. Derevianko, V . A. Dzuba, and V . V . Flambaum, Highly charged ions as a basis of optical atomic clockwork of exceptional accuracy, Phys. Rev. Lett. 109, 180801 (2012). 17
2012
-
[12]
Lange, N
R. Lange, N. Huntemann, J. M. Rahm, C. Sanner, H. Shao, B. Lipphardt, C. Tamm, S. Weyers, and E. Peik, Improved limits for violations of local position invariance from atomic clock comparisons, Phys. Rev. Lett.126, 011102 (2021)
2021
-
[13]
C. A. Holliman, M. Fan, A. Contractor, S. M. Brewer, and A. M. Jayich, Radium ion optical clock, Phys. Rev. Lett. 128, 033202 (2022)
2022
-
[14]
Zheng, J
X. Zheng, J. Dolde, V . Lochab, B. N. Merriman, H. Li, and S. Kolkowitz, Differential clock comparisons with a multiplexed optical lattice clock, Nature 602, 425 (2022)
2022
-
[15]
D. Yu, J. Zhang, S. Zhang, and J. Chen, Prospects for an active optical clock based on cavityless lasing, Advanced Quantum Technologies 7, 2300308 (2024)
2024
-
[16]
Ushijima, M
I. Ushijima, M. Takamoto, M. Das, T. Ohkubo, and H. Katori, Cryogenic optical lattice clocks, Nature Photonics 9, 185 (2015)
2015
-
[17]
C. W. Chou, D. B. Hume, T. Rosenband, and D. J. Wineland, Optical clocks and relativity, Science 329, 1630 (2010)
2010
-
[18]
Z. L. Newman, V . Maurice, T. Drake, J. R. Stone, T. C. Briles, D. T. Spencer, C. Fredrick, Q. Li, D. Westly, B. R. Ilic, B. Shen, M.-G. Suh, K. Y . Yang, C. Johnson, D. M. S. Johnson, L. Hollberg, K. J. Vahala, K. Srinivasan, S. A. Diddams, J. Kitching, S. B. Papp, and M. T. ...
2019
-
[19]
H. N. Hausser, J. Keller, T. Nordmann, N. M. Bhatt, J. Kiethe, H. Liu, I. M. Richter, M. von Boehn, J. Rahm, S. Weyers, E. Benkler, B. Lipphardt, S. D ¨orscher, K. Stahl, J. Klose, C. Lisdat, M. Filzinger, N. Huntemann, E. Peik, and T. E. Mehlst ¨aubler, 115in+−172yb+ coulomb ...
2025
-
[20]
C. W. Chou, D. B. Hume, J. C. J. Koelemeij, D. J. Wineland, and T. Rosenband, Frequency comparison of two high-accuracy al+ optical clocks, Phys. Rev. Lett. 104, 070802 (2010)
2010
-
[21]
Huang, B
Y . Huang, B. Zhang, M. Zeng, Y . Hao, Z. Ma, H. Zhang, H. Guan, Z. Chen, M. Wang, and K. Gao, Liquid-nitrogen-cooled Ca+ optical clock with systematic uncertainty of 3 × 10−18, Phys. Rev. Appl. 17, 034041 (2022)
2022
-
[22]
K. W. Martin, G. Phelps, N. D. Lemke, M. S. Bigelow, B. Stuhl, M. Wojcik, M. Holt, I. Coddington, M. W. Bishop, and J. H. Burke, Compact optical atomic clock based on a two-photon transition in rubidium, Phys. Rev. Appl. 9, 014019 (2018)
2018
-
[23]
T. Shi, Q. Wei, X. Qin, Z. Liu, K. Chen, S. Cao, H. Shi, Z. Liu, and J. Chen, Dual-frequency optical-microwave atomic clocks based on cesium atoms, Photon. Res. 12, 1972 (2024)
2024
-
[24]
Q. Hao, S. Yang, J. Ruan, P. Yun, and S. Zhang, Integrated pulsed optically pumped rb atomic clock with frequency stability of 10 −15, Phys. Rev. Appl. 21, 024003 (2024)
2024
-
[25]
Phelps, N
G. Phelps, N. Lemke, C. Erickson, J. Burke, and K. Martin, Compact optical clock with 5 × 10−13 instability at 1 s, NA VIGATION65, 49 (2018)
2018
-
[26]
Z. L. Newman, V . Maurice, C. Fredrick, T. Fortier, H. Leopardi, L. Hollberg, S. A. Diddams, J. Kitching, and M. T. Hummon, High- performance, compact optical standard, Opt. Lett. 46, 4702 (2021)
2021
-
[27]
Callejo, A
M. Callejo, A. Mursa, R. Vicarini, E. Klinger, Q. Tanguy, J. Millo, N. Passilly, and R. Boudot, Short-term stability of a microcell optical reference based on the rb atom two-photon transition at 778 nm, J. Opt. Soc. Am. B 42, 151 (2025)
2025
-
[28]
K. W. Martin, B. Stuhl, J. Eugenio, M. S. Safronova, G. Phelps, J. H. Burke, and N. D. Lemke, Frequency shifts due to stark effects on a rubidium two-photon transition, Phys. Rev. A 100, 023417 (2019)
2019
-
[29]
Yudin, M
V . Yudin, M. Y . Basalaev, A. Taichenachev, J. Pollock, Z. Newman, M. Shuker, A. Hansen, M. Hummon, R. Boudot, E. Donley, and J. Kitching, General methods for suppressing the light shift in atomic clocks using power modulation, Phys. Rev. Appl. 14, 024001 (2020)
2020
-
[30]
Gerginov and K
V . Gerginov and K. Beloy, Two-photon optical frequency reference with active ac stark shift cancellation, Phys. Rev. Appl. 10, 014031 (2018)
2018
-
[31]
M. A. Hafiz, G. Coget, E. D. Clercq, and R. Boudot, Doppler-free spectroscopy on the cs d1 line with a dual-frequency laser, Opt. Lett. 41, 2982 (2016)
2016
-
[32]
N. D. Lemke, K. W. Martin, R. Beard, B. K. Stuhl, A. J. Metcalf, and J. D. Elgin, Measurement of optical rubidium clock frequency spanning 65 days, Sensors 22, 10.3390/s22051982 (2022)
2022 doi
-
[33]
V . I. Yudin, M. Y . Basalaev, A. V . Taichenachev, O. N. Prudnikov, D. A. Radnatarov, S. M. Kobtsev, S. M. Ignatovich, and M. N. Skvortsov, Frequency shift caused by the line-shape asymmetry of the resonance of coherent population trapping, Phys. Rev. A 108, 013103 (2023)
2023
-
[34]
Abdel Hafiz and R
M. Abdel Hafiz and R. Boudot, A coherent population trapping Cs vapor cell atomic clock based on push-pull optical pumping, Journal of Applied Physics 118, 124903 (2015)
2015
-
[35]
V . I. Yudin, A. V . Taichenachev, M. Y . Basalaev, and D. V . Kovalenko, Dynamic regime of coherent population trapping and optimization of frequency modulation parameters in atomic clocks, Opt. Express 25, 2742 (2017)
2017
-
[36]
R. Fang, C. Han, X. Jiang, Y . Qiu, Y . Guo, M. Zhao, J. Huang, B. Lu, and C. Lee, Temporal analog of fabry-p´erot resonator via coherent population trapping, npj Quantum Information 7, 143 (2021)
2021
-
[37]
S. F. Huelga, C. Macchiavello, T. Pellizzari, A. K. Ekert, M. B. Plenio, and J. I. Cirac, Improvement of frequency standards with quantum entanglement, Phys. Rev. Lett. 79, 3865 (1997). 18
1997
-
[38]
Perrella, P
C. Perrella, P. Light, J. Anstie, F. Baynes, R. White, and A. Luiten, Dichroic two-photon rubidium frequency standard, Phys. Rev. Appl. 12, 054063 (2019)
2019
-
[39]
Holzwarth, M
R. Holzwarth, M. Zimmermann, T. Udem, and T. Hansch, Optical clockworks and the measurement of laser frequencies with a mode- locked frequency comb, IEEE Journal of Quantum Electronics 37, 1493 (2001)
2001
-
[40]
Fortier and E
T. Fortier and E. Baumann, 20 years of developments in optical frequency comb technology and applications, Communications Physics 2, 153 (2019)
2019
-
[41]
N. B. Phillips, A. V . Gorshkov, and I. Novikova, Light storage in an optically thick atomic ensemble under conditions of electromagneti- cally induced transparency and four-wave mixing, Phys. Rev. A83, 063823 (2011)
2011
-
[42]
Abram, Quantum theory of light propagation: Linear medium, Phys
I. Abram, Quantum theory of light propagation: Linear medium, Phys. Rev. A 35, 4661 (1987)
1987
-
[43]
K. J. Blow, R. Loudon, S. J. D. Phoenix, and T. J. Shepherd, Continuum fields in quantum optics, Phys. Rev. A 42, 4102 (1990)
1990
-
[44]
P. D. Drummond and S. J. Carter, Quantum-field theory of squeezing in solitons, J. Opt. Soc. Am. B 4, 1565 (1987)
1987
-
[45]
Fleischhauer and M
M. Fleischhauer and M. O. Scully, Quantum sensitivity limits of an optical magnetometer based on atomic phase coherence, Phys. Rev. A 49, 1973 (1994)
1994
-
[46]
Gardiner and P
C. Gardiner and P. Zoller, Quantum noise: a handbook of Markovian and non-Markovian quantum stochastic methods with applications to quantum optics (Springer Science & Business Media, 2004)
2004
-
[47]
Boller, A
K.-J. Boller, A. Imamo ˘glu, and S. E. Harris, Observation of electromagnetically induced transparency, Phys. Rev. Lett.66, 2593 (1991)
1991
-
[48]
L. E. Drain and B. C. Moss, The frequency shifting of laser light by electro-optic techniques, Opto-electronics 4, 429 (1972)
1972
-
[49]
Z. Zeng, Z. Zhang, L. Zhang, S. Zhang, Y . Zhang, B. Sun, and Y . Liu, Stable and finely tunable optoelectronic oscillator based on stimulated brillouin scattering and an electro-optic frequency shift, Appl. Opt. 59, 589 (2020)
2020
-
[50]
R. J. Jones, K. D. Moll, M. J. Thorpe, and J. Ye, Phase-coherent frequency combs in the vacuum ultraviolet via high-harmonic generation inside a femtosecond enhancement cavity, Phys. Rev. Lett.94, 193201 (2005)
2005
-
[51]
Schulte, C
M. Schulte, C. Lisdat, P. O. Schmidt, U. Sterr, and K. Hammerer, Prospects and challenges for squeezing-enhanced optical atomic clocks, Nature Communications 11, 5955 (2020)
2020
-
[52]
D. M. Farkas, A. Zozulya, and D. Z. Anderson, A compact microchip atomic clock based on all-optical interrogation of ultra-cold trapped rb atoms, Applied Physics B 101, 705 (2010)
2010
-
[53]
Gopinath, Y
G. Gopinath, Y . Li, and S. Davuluri, Continuous variable entanglement between propagating optical modes using optomechanics, EPJ Quantum Technology 11, 41 (2024)
2024
-
[54]
Pezz `e, A
L. Pezz `e, A. Smerzi, M. K. Oberthaler, R. Schmied, and P. Treutlein, Quantum metrology with nonclassical states of atomic ensembles, Rev. Mod. Phys. 90, 035005 (2018)
2018
-
[55]
J. D. Weinstein, K. Beloy, and A. Derevianko, Entangling the lattice clock: Towards heisenberg-limited timekeeping, Phys. Rev. A 81, 030302 (2010)
2010
-
[56]
Finkelstein, S
R. Finkelstein, S. Bali, O. Firstenberg, and I. Novikova, A practical guide to electromagnetically induced transparency in atomic vapor, New Journal of Physics 25, 035001 (2023)
2023
-
[57]
L.-C. Ha, X. Zhang, N. Dao, and K. R. Overstreet, D1 line broadening and hyperfine frequency shift coefficients for 87Rb and 133Cs in ne, ar, and n2, Phys. Rev. A 103, 022826 (2021)
2021
-
[58]
C. J. McKinstrie, T. J. Stirling, and A. S. Helmy, Laser linewidths: tutorial, J. Opt. Soc. Am. B 38, 3837 (2021)
2021
-
[59]
M. O. Scully and M. S. Zubairy, Quantum Optics (Cambridge University Press, 1997)
1997
-
[60]
M. J. McDonnell, D. N. Stacey, and A. M. Steane, Laser linewidth effects in quantum state discrimination by electromagnetically induced transparency, Phys. Rev. A70, 053802 (2004)
2004
-
[61]
L. Yang, B. Wei, H. Xu, Z. Wang, and X. Jin, Linewidth compression of dfb laser with a high ratio based on sil and pdh, IEEE Photonics Technology Letters 36, 23 (2024)
2024
-
[62]
Zhang, D
J. Zhang, D. Wei, C. Xie, and K. Peng, Characteristics of absorption and dispersion for rubidium d2 lines with the modulation transfer spectrum, Opt. Express 11, 1338 (2003)
2003
-
[63]
J. Ye, L. S. Ma, and J. L. Hall, Molecular iodine clock, Phys. Rev. Lett. 87, 270801 (2001)
2001
-
[64]
Nevsky, R
A. Nevsky, R. Holzwarth, J. Reichert, T. Udem, T. H¨ansch, J. Zanthier, H. Walther, H. Schnatz, F. Riehle, P. Pokasov, M. Skvortsov, and S. Bagayev, Frequency comparison and absolute frequency measurement of i2-stabilized lasers at 532 nm, Optics Communications 192, 263 (2001)
2001
-
[65]
Lurie, F
A. Lurie, F. N. Baynes, J. D. Anstie, P. S. Light, F. Benabid, T. M. Stace, and A. N. Luiten, High-performance iodine fiber frequency standard, Opt. Lett. 36, 4776 (2011)
2011
-
[66]
Perrella, P
C. Perrella, P. S. Light, J. D. Anstie, F. N. Baynes, F. Benabid, and A. N. Luiten, Two-color rubidium fiber frequency standard, Opt. Lett. 38, 2122 (2013)
2013
Reviewed August 6, 2026 · model on record in the stance chip above.
Discussion (0). Continue with ORCID to comment.