NeuralBoneReg: An Instance-Specific Label-Free Point Cloud-Based Method for Multi-Modal Bone Surface Registration
Pith reviewed 2026-05-25 07:39 UTC · model grok-4.3
The pith
NeuralBoneReg performs accurate multi-modal bone surface registration in a self-supervised, instance-specific manner using point clouds and neural distance fields.
A machine-rendered reading of the paper's core claim, the machinery that carries it, and where it could break.
Core claim
The central discovery is that an instance-specific neural unsigned distance field representing the preoperative bone surface, paired with an MLP registration module, can recover rigid transformations to align intraoperative point clouds from heterogeneous modalities, achieving the reported error levels on the evaluated datasets without inter-subject training data.
What carries the argument
Implicit neural unsigned distance field (UDF) for the preoperative bone combined with MLP-based hypothesis generation for rigid transformations.
If this is right
- It operates without inter-subject training data, relying only on the specific instance.
- It achieves mean RRE/RTE of 1.83°/2.02 mm on UltraBones100k dataset.
- It generalizes to hip and spine anatomies with errors of 1.90°/1.56 mm and 3.78°/2.80 mm respectively.
- It supports both global initialization and local refinement stages.
Where Pith is reading between the lines
- Surgeons could potentially use this to reduce reliance on manual alignment steps.
- Extension to non-rigid deformations might be possible if the UDF representation is adapted accordingly.
- The method's performance on very sparse point clouds remains to be tested in practice.
- Integration into existing CAOS software could streamline workflow if inference times are acceptable.
Load-bearing premise
Point clouds derived from different modalities provide sufficiently complete and consistent surface information for the neural model to determine the correct rigid alignment without correspondences.
What would settle it
A test on a new dataset where the intraoperative point cloud is significantly incomplete or noisy, resulting in registration errors exceeding 5 degrees or 5 mm, would falsify the claim of robust cross-modal performance.
Figures
read the original abstract
In computer- and robot-assisted orthopedic surgery (CAOS), patient-specific surgical plans derived from preoperative imaging define target locations and implant trajectories. During surgery, these plans must be accurately transferred, relying on precise cross-registration between preoperative and intraoperative data. However, substantial modality heterogeneity across imaging modalities makes this registration challenging and error-prone. Robust, automatic, and modality-agnostic bone surface registration is therefore clinically important. We propose NeuralBoneReg, a self-supervised, surface-based framework that registers bone surfaces using 3D point clouds as a modality-agnostic representation. NeuralBoneReg includes two modules: an implicit neural unsigned distance field (UDF) that learns the preoperative bone model, and an MLP-based registration module that performs global initialization and local refinement by generating transformation hypotheses to align the intraoperative point cloud with the neural UDF. Unlike SOTA supervised methods, NeuralBoneReg operates in a self-supervised manner, without requiring inter-subject training data. We evaluated NeuralBoneReg against baseline methods on two publicly available multi-modal datasets: a CT-ultrasound dataset of the fibula and tibia (UltraBones100k) and a CT-RGB-D dataset of spinal vertebrae (SpineDepth). The evaluation also includes a newly introduced CT-ultrasound dataset of cadaveric subjects containing femur and pelvis (UltraBones-Hip), which will be made publicly available. NeuralBoneReg matches or surpasses existing methods across all datasets, achieving mean RRE/RTE of 1.83{\deg}/2.02 mm on UltraBones100k, 1.90{\deg}/1.56 mm on UltraBones-Hip, and 3.78{\deg}/2.80 mm on SpineDepth. These results demonstrate strong generalizability across anatomies and modalities, providing robust and accurate cross-modal alignment for CAOS.
Editorial analysis
A structured set of objections, weighed in public.
Referee Report
Summary. The paper proposes NeuralBoneReg, a self-supervised, instance-specific framework for multi-modal bone surface registration in CAOS. It represents preoperative bone surfaces via an implicit neural unsigned distance field (UDF) learned from point clouds and uses an MLP to generate transformation hypotheses for global initialization and local refinement, aligning intraoperative point clouds without inter-subject labels or explicit correspondences. The method is evaluated on UltraBones100k (CT-US), a new UltraBones-Hip dataset (CT-US of femur/pelvis), and SpineDepth (CT-RGB-D), claiming to match or surpass baselines with mean RRE/RTE of 1.83°/2.02 mm, 1.90°/1.56 mm, and 3.78°/2.80 mm respectively.
Significance. If the results hold, the work offers a clinically relevant advance by enabling modality-agnostic registration without large labeled inter-subject datasets, a strength given the heterogeneity in CAOS imaging. The self-supervised UDF+MLP design and public release of UltraBones-Hip are positive contributions that could reduce reliance on supervised training.
major comments (2)
- [Abstract] Abstract: the central performance claim (matching or surpassing SOTA with the listed RRE/RTE values) rests on the unverified precondition that point clouds extracted from ultrasound and RGB-D are sufficiently complete, dense, and geometrically consistent with CT surfaces for the neural UDF to yield a usable loss landscape and for the MLP to converge reliably; no analysis, ablation, or discussion of partial coverage, density variation, or modality artifacts is provided to support this.
- [Results] Results (as summarized): the reported mean errors lack standard deviations, error bars, statistical significance tests against baselines, or details on data exclusion rules, making it impossible to verify whether the competitive numbers are robust or driven by favorable cases.
minor comments (1)
- [Abstract] The abstract and method description would benefit from explicit notation for the UDF loss and MLP hypothesis generation to clarify the self-supervised objective.
Simulated Author's Rebuttal
We thank the referee for the detailed and constructive feedback. We address the two major comments point by point below, indicating where revisions will be made to strengthen the manuscript. Both comments identify areas where additional analysis or reporting would improve clarity and verifiability.
read point-by-point responses
-
Referee: [Abstract] Abstract: the central performance claim (matching or surpassing SOTA with the listed RRE/RTE values) rests on the unverified precondition that point clouds extracted from ultrasound and RGB-D are sufficiently complete, dense, and geometrically consistent with CT surfaces for the neural UDF to yield a usable loss landscape and for the MLP to converge reliably; no analysis, ablation, or discussion of partial coverage, density variation, or modality artifacts is provided to support this.
Authors: We agree that the abstract's performance claims implicitly rely on the quality of the extracted intraoperative point clouds. The full manuscript describes the point-cloud extraction pipelines for each dataset (UltraBones100k, UltraBones-Hip, SpineDepth) and notes that these are real clinical acquisitions, but it does not include dedicated analysis of coverage, density variation, or artifact effects. To address this, we will add a new subsection in the Experiments section that (i) quantifies point-cloud coverage and density statistics across the test cases, (ii) discusses modality-specific artifacts observed in the data, and (iii) reports an ablation on registration accuracy under controlled down-sampling and partial-view conditions. This will make the precondition explicit and provide supporting evidence. revision: yes
-
Referee: [Results] Results (as summarized): the reported mean errors lack standard deviations, error bars, statistical significance tests against baselines, or details on data exclusion rules, making it impossible to verify whether the competitive numbers are robust or driven by favorable cases.
Authors: The current manuscript reports only mean RRE/RTE values. We acknowledge that the absence of standard deviations, error bars, statistical tests, and explicit data-exclusion criteria limits assessment of robustness. In the revised version we will (i) report mean ± standard deviation for all metrics, (ii) include error-bar plots in the result figures, (iii) add paired statistical significance tests (e.g., Wilcoxon signed-rank) against the baselines, and (iv) state the data-exclusion rules (if any) applied during evaluation. These additions will be placed in the Results and supplementary material. revision: yes
Circularity Check
No circularity; self-supervised method and dataset evaluations remain independent
full rationale
The paper presents NeuralBoneReg as a self-supervised framework (neural UDF for preoperative model + MLP hypothesis generator for registration) and reports empirical registration errors on held-out public and newly introduced datasets. No equations reduce the reported RRE/RTE values to quantities fitted from the evaluation data itself, no self-citation chain bears the central claim, and the modality-agnostic point-cloud assumption is stated as a precondition rather than derived by construction from the results. The derivation chain is therefore self-contained against external benchmarks.
Axiom & Free-Parameter Ledger
free parameters (1)
- UDF and MLP network hyperparameters
axioms (2)
- domain assumption Neural networks can learn a faithful unsigned distance field representation of bone geometry from a single preoperative scan
- domain assumption Point clouds from different modalities share a common rigid transformation to the preoperative surface
Reference graph
Works this paper leans on
- [1]
- [2]
-
[3]
Sugano, Computer-assisted orthopedic surgery, Journal of Or- thopaedic Science 8 (2003) 442–448
N. Sugano, Computer-assisted orthopedic surgery, Journal of Or- thopaedic Science 8 (2003) 442–448
work page 2003
- [4]
-
[5]
K.-M. Scheufler, J. Franke, A. Eckardt, H. Dohmen, Accuracy of image-guided pedicle screw placement using intraoperative computed tomography-based navigation with automated referencing, part i: cer- vicothoracic spine, Neurosurgery 69 (4) (2011) 782–795
work page 2011
-
[6]
E. M. Kanlić, F. DeLaRosa, M. Pirela-Cruz, Computer assisted or- thopaedic surgery–caos, Bosnian journal of basic medical sciences 6 (1) (2006) 7
work page 2006
- [7]
- [8]
-
[9]
C. Wandvik, M. E. Greil, S. Colby, D. Gautam, M. D. Mazur, Limita- tions of current robot-assisted pedicle screw insertion systems, Neuro- surgical Focus 57 (6) (2024) E14
work page 2024
-
[10]
N. J. Lee, I. A. Buchanan, V. Boddapati, J. Mathew, G. Marciano, P. J. Park, E. Leung, A. L. Buchholz, J. Pollina, E. Jazini, et al., Do robot-related complications influence 1 year reoperations and other clin- ical outcomes after robot-assisted lumbar arthrodesis? a multicenter as- sessment of 320 patients, Journal of Orthopaedic Surgery and Research 16 ...
work page 2021
-
[11]
J. Kubicek, F. Tomanec, M. Cerny, D. Vilimek, M. Kalova, D. Oczka, Recent trends, technical concepts and components of computer-assisted 29 orthopedic surgery systems: a comprehensive review, Sensors 19 (23) (2019) 5199
work page 2019
- [12]
-
[13]
J. Tonetti, M. Boudissa, G. Kerschbaumer, O. Seurat, Role of 3d intra- operative imaging in orthopedic and trauma surgery, Orthopaedics & Traumatology: Surgery & Research 106 (1) (2020) S19–S25
work page 2020
-
[14]
S. Park, W. Plishker, H. Quon, J. Wong, R. Shekhar, J. Lee, De- formable registration of ct and cone-beam ct with local intensity match- ing, Physics in Medicine & Biology 62 (3) (2017) 927
work page 2017
-
[15]
P.-L. Docquier, L. Paul, O. Cartiaux, C. Delloye, X. Banse, Computer- assisted resection and reconstruction of pelvic tumor sarcoma, Sarcoma 2010 (1) (2010) 125162
work page 2010
-
[16]
M. Pojskić, M. Bopp, B. Saß, A. Kirschbaum, C. Nimsky, B. Carl, Intraoperative computed tomography-based navigation with augmented reality for lateral approaches to the spine, Brain Sciences 11 (5) (2021) 646
work page 2021
-
[17]
P. Markelj, D. Tomaževič, B. Likar, F. Pernuš, A review of 3d/2d regis- tration methods for image-guided interventions, Medical image analysis 16 (3) (2012) 642–661
work page 2012
-
[18]
Y. Otake, M. Armand, R. S. Armiger, M. D. Kutzer, E. Basafa, P. Kazanzides, R. H. Taylor, Intraoperative image-based multiview 2d/3d registration for image-guided orthopaedic surgery: incorporation offiducial-basedc-armtrackingandgpu-acceleration, IEEEtransactions on medical imaging 31 (4) (2011) 948–962
work page 2011
-
[19]
G. P. Penney, J. Weese, J. A. Little, P. Desmedt, D. L. Hill, et al., A comparison of similarity measures for use in 2-d-3-d medical image registration, IEEE transactions on medical imaging 17 (4) (1998) 586– 595
work page 1998
-
[20]
P.-C. Ku, A. Martin-Gomez, C. Gao, R. Grupp, S. C. Mears, M. Ar- mand, Towards 2d/3d registration of the preoperative mri to intraop- erative fluoroscopic images for visualisation of bone defects, Computer 30 Methods in Biomechanics and Biomedical Engineering: Imaging & Vi- sualization 11 (4) (2023) 1096–1105
work page 2023
-
[21]
I. Hacihaliloglu, A. Rasoulian, R. N. Rohling, P. Abolmaesumi, Lo- cal phase tensor features for 3-d ultrasound to statistical shape+ pose spine model registration, IEEE transactions on Medical Imaging 33 (11) (2014) 2167–2179
work page 2014
- [22]
-
[23]
G. P. Penney, D. C. Barratt, C. S. Chan, M. Slomczykowski, T. J. Carter, P. J. Edwards, D. J. Hawkes, Cadaver validation of intensity- based ultrasound to ct registration, Medical image analysis 10 (3) (2006) 385–395
work page 2006
-
[24]
P. Pandey, P. Guy, A. J. Hodgson, R. Abugharbieh, Fast and automatic bone segmentation and registration of 3d ultrasound to ct for the full pelvic anatomy: a comparative study, International Journal of Com- puter Assisted Radiology and Surgery 13 (10) (2018) 1515–1524. URLhttp://dx.doi.org/10.1007/s11548-018-1788-5
-
[25]
W. Wein, A. Khamene, D.-A. Clevert, O. Kutter, N. Navab, Simula- tion and fully automatic multimodal registration of medical ultrasound, in: Medical Image Computing and Computer-Assisted Intervention– MICCAI 2007: 10th International Conference, Brisbane, Australia, Oc- tober 29-November 2, 2007, Proceedings, Part I 10, Springer, 2007, pp. 136–143
work page 2007
-
[26]
D. K. Bae, S. J. Song, Computer assisted navigation in knee arthro- plasty, Clinics in orthopedic surgery 3 (4) (2011) 259–267
work page 2011
-
[27]
K. C. Anderson, K. C. Buehler, D. C. Markel, Computer assisted naviga- tion in total knee arthroplasty: comparison with conventional methods, The Journal of arthroplasty 20 (2005) 132–138
work page 2005
-
[28]
D. A. Wilson, C. Anglin, F. Ambellan, C. M. Grewe, A. Tack, H. Lamecker, M. Dunbar, S. Zachow, Validation of three-dimensional 31 models of the distal femur created from surgical navigation point cloud data for intraoperative and postoperative analysis of total knee arthroplasty, International Journal of Computer Assisted Radiology and Surgery 12 (12) (20...
work page 2017
-
[29]
F. Liebmann, M. von Atzigen, D. Stütz, J. Wolf, L. Zingg, D. Suter, N. A. Cavalcanti, L. Leoty, H. Esfandiari, J. G. Snedeker, M. R. Os- wald, M. Pollefeys, M. Farshad, P. Fürnstahl, Automatic registration withcontinuousposeupdatesformarker-lesssurgicalnavigationinspine surgery, Medical Image Analysis 91 (2024) 103027
work page 2024
-
[30]
X. Hu, A. Nguyen, F. R. y Baena, Occlusion-robust visual markerless bone tracking for computer-assisted orthopedic surgery, IEEE Transac- tions on Instrumentation and Measurement 71 (2021) 1–11
work page 2021
-
[31]
I. Félix, C. Raposo, M. Antunes, P. Rodrigues, J. P. Barreto, Towards markerless computer-aided surgery combining deep segmentation and geometric pose estimation: application in total knee arthroplasty, Com- puter Methods in Biomechanics and Biomedical Engineering: Imaging & Visualization 9 (3) (2021) 271–278
work page 2021
-
[32]
X.Hu, F.R.y.Baena, Automaticbonesurfacerestorationformarkerless computer-assisted orthopaedic surgery, Chinese Journal of Mechanical Engineering 35 (1) (2022) 18
work page 2022
-
[33]
P. Rodrigues, M. Antunes, C. Raposo, P. Marques, F. Fonseca, J. P. Barreto, Deep segmentation leverages geometric pose estimation in computer-aided total knee arthroplasty, Healthcare technology letters 6 (6) (2019) 226–230
work page 2019
-
[34]
R. B. Grupp, M. Unberath, C. Gao, R. A. Hegeman, R. J. Murphy, C. P. Alexander, Y. Otake, B. A. McArthur, M. Armand, R. H. Taylor, Automatic annotation of hip anatomy in fluoroscopy for robust and efficient 2d/3d registration, International journal of computer assisted radiology and surgery 15 (5) (2020) 759–769
work page 2020
-
[35]
P.-C. Ku, M. Liu, R. Grupp, A. Harris, J. K. Oni, S. C. Mears, A. Martin-Gomez, M. Armand, End-to-end 2d/3d registration from pre- operative mri to intra-operative fluoroscopy for orthopedic procedures, 32 International Journal of Computer Assisted Radiology and Surgery (2025) 1–12
work page 2025
- [36]
-
[37]
W. Wein, A. Karamalis, A. Baumgartner, N. Navab, Automatic bone detection and soft tissue aware ultrasound–ct registration for computer- aided orthopedic surgery, International journal of computer assisted ra- diology and surgery 10 (2015) 971–979
work page 2015
- [38]
-
[39]
K. A. Eppenhof, M. W. Lafarge, M. Veta, J. P. Pluim, Progressively trained convolutional neural networks for deformable image registration, IEEE transactions on medical imaging 39 (5) (2019) 1594–1604
work page 2019
-
[40]
H. Guo, X. Xu, S. Xu, B. J. Wood, P. Yan, End-to-end ultrasound frame to volume registration, in: Medical Image Computing and Com- puter Assisted Intervention–MICCAI 2021: 24th International Confer- ence, Strasbourg, France, September 27–October 1, 2021, Proceedings, Part IV 24, Springer, 2021, pp. 56–65
work page 2021
-
[41]
URLhttp://dx.doi.org/10.1007/s11548-018-1756-0
M.Ciganovic, F.Ozdemir, F.Pean, P.Fuernstahl, C.Tanner, O.Goksel, Registration of 3d freehand ultrasound to a bone model for orthopedic procedures of the forearm, International Journal of Computer Assisted Radiology and Surgery 13 (6) (2018) 827–836. URLhttp://dx.doi.org/10.1007/s11548-018-1756-0
- [42]
-
[43]
R. Li, A. Davoodi, Y. Cai, K. Niu, G. Borghesan, N. Cavalcanti, A. Mas- salimova, F. Carrillo, C. J. Laux, M. Farshad, P. Fürnstahl, E. V. 33 Poorten, Robot-assisted ultrasound reconstruction for spine surgery: from bench-top to pre-clinical study, International Journal of Computer Assisted Radiology and Surgery 18 (9) (2023) 1613–1623. URLhttp://dx.doi.o...
-
[44]
A. Sotiras, C. Davatzikos, N. Paragios, Deformable medical image regis- tration: A survey, IEEE transactions on medical imaging 32 (7) (2013) 1153–1190
work page 2013
-
[45]
J.Woo, M.Stone, J.L.Prince, Multimodalregistrationviamutualinfor- mation incorporating geometric and spatial context, IEEE Transactions on Image Processing 24 (2) (2014) 757–769
work page 2014
-
[46]
R. Li, A. Davoodi, Y. Cai, G. Borghesan, N. Cavalcanti, C. J. Laux, M. Farshad, F. Carrillo, P. Fürnstahl, E. Vander Poorten, Development and evaluation of robot-assisted ultrasound navigation system for pedi- cle screw placement: An ex-vivo animal validation, The International Journal of Medical Robotics and Computer Assisted Surgery 20 (1) (10 2023). UR...
-
[47]
L. Wu, N. A. Cavalcanti, M. Seibold, G. Loggia, L. Reissner, J. Hein, S. Beeler, A. Viehöfer, S. Wirth, L. Calvet, P. Fürnstahl, Ultra- bones100k: A reliable automated labeling method and large-scale dataset for ultrasound-based bone surface extraction, Computers in Bi- ology and Medicine 194 (2025) 110435
work page 2025
-
[48]
J. N. Zhang, Y. Fan, D. J. Hao, Risk factors for robot-assisted spinal pedicle screw malposition, Scientific reports 9 (1) (2019) 3025
work page 2019
-
[49]
L. Ma, Z. Zhao, F. Chen, B. Zhang, L. Fu, H. Liao, Augmented real- ity surgical navigation with ultrasound-assisted registration for pedicle screw placement: a pilot study, International journal of computer as- sisted radiology and surgery 12 (12) (2017) 2205–2215
work page 2017
-
[50]
M. A. Fischler, R. C. Bolles, Random sample consensus: a paradigm for model fitting with applications to image analysis and automated cartography, Communications of the ACM 24 (6) (1981) 381–395
work page 1981
-
[51]
Q.-Y. Zhou, J. Park, V. Koltun, Fast global registration, in: European conference on computer vision, Springer, 2016, pp. 766–782. 34
work page 2016
-
[52]
C. Gsaxner, A. Pepe, J. Wallner, D. Schmalstieg, J. Egger, Markerless image-to-face registration for untethered augmented reality in head and neck surgery, in: International Conference on Medical Image Computing and Computer-Assisted Intervention, Springer, 2019, pp. 236–244
work page 2019
-
[53]
L. Liu, Y. Zhao, A. Li, X. Yu, X. Xiao, S. Liu, M. Q.-H. Meng, A photoacoustics-enhanced drilling probe for radiation-free pedicle screw implantation in spinal surgery, Frontiers in Bioengineering and Biotech- nology 10 (2022) 1000950
work page 2022
-
[54]
Y. Ao, H. Esfandiari, F. Carrillo, C. J. Laux, Y. As, R. Li, K. Van Ass- che, A. Davoodi, N. A. Cavalcanti, M. Farshad, et al., Saferplan: Safe deep reinforcement learning for intraoperative planning of pedicle screw placement, Medical Image Analysis 99 (2025) 103345
work page 2025
-
[55]
J. Liu, J. Hao, H. Lin, W. Pan, J. Yang, Y. Feng, G. Wang, J. Li, Z. Jin, Z. Zhao, et al., Deep learning-enabled 3d multimodal fusion of cone-beam ct and intraoral mesh scans for clinically applicable tooth- bone reconstruction, Patterns 4 (9) (2023)
work page 2023
- [56]
-
[57]
A. Chan, B. Coutts, E. Parent, E. Lou, Development and evaluation of ct-to-3d ultrasound image registration algorithm in vertebral phantoms for spine surgery, Annals of Biomedical Engineering 49 (1) (2021) 310– 321
work page 2021
-
[58]
M. Unberath, C. Gao, Y. Hu, M. Judish, R. H. Taylor, M. Armand, R. Grupp, The impact of machine learning on 2d/3d registration for image-guided interventions: A systematic review and perspective, Fron- tiers in Robotics and AI 8 (2021) 716007
work page 2021
- [59]
-
[60]
U.Castellani, A.Bartoli, 3dshaperegistration, in: 3DImaging, Analysis and Applications, Springer, 2020, pp. 353–411. 35
work page 2020
-
[61]
F. Liebmann, D. Stütz, D. Suter, S. Jecklin, J. G. Snedeker, M. Farshad, P. Fürnstahl, H. Esfandiari, Spinedepth: A multi-modal data collection approach for automatic labelling and intraoperative spinal shape recon- struction based on rgb-d data, Journal of Imaging 7 (9) (2021) 164. URLhttp://dx.doi.org/10.3390/jimaging7090164
-
[62]
P. J. Besl, N. D. McKay, Method for registration of 3-d shapes, in: Sensor fusion IV: control paradigms and data structures, Vol. 1611, Spie, 1992, pp. 586–606
work page 1992
-
[63]
E. W. Nottmeier, T. L. Crosby, Timing of paired points and surface matching registration in three-dimensional (3d) image-guided spinal surgery, Clinical Spine Surgery 20 (4) (2007) 268–270
work page 2007
-
[64]
P. Foroughi, R. H. Taylor, G. Fichtinger, Automatic initialization for 3d bone registration, in: Medical Imaging 2008: Visualization, Image- Guided Procedures, and Modeling, Vol. 6918, SPIE, 2008, pp. 895–902
work page 2008
- [65]
-
[66]
C. Choy, J. Park, V. Koltun, Fully convolutional geometric features, in: Proceedings of the IEEE/CVF international conference on computer vision, 2019, pp. 8958–8966
work page 2019
- [67]
-
[68]
S. Ao, Q. Hu, B. Yang, A. Markham, Y. Guo, Spinnet: Learning a gen- eral surface descriptor for 3d point cloud registration, in: Proceedings of the IEEE/CVF conference on computer vision and pattern recognition, 2021, pp. 11753–11762
work page 2021
-
[69]
A. Zeng, S. Song, M. Nießner, M. Fisher, J. Xiao, T. Funkhouser, 3dmatch: Learning local geometric descriptors from rgb-d reconstruc- tions, in: Proceedings of the IEEE conference on computer vision and pattern recognition, 2017, pp. 1802–1811. 36
work page 2017
-
[70]
H. Wang, Y. Liu, Z. Dong, W. Wang, You only hypothesize once: Point cloud registration with rotation-equivariant descriptors, in: Proceedings of the 30th ACM International Conference on Multimedia, 2022, pp. 1630–1641
work page 2022
- [71]
-
[72]
G. D. Pais, S. Ramalingam, V. M. Govindu, J. C. Nascimento, R. Chel- lappa, P. Miraldo, 3dregnet: A deep neural network for 3d point reg- istration, in: Proceedings of the IEEE/CVF conference on computer vision and pattern recognition, 2020, pp. 7193–7203
work page 2020
-
[73]
W. Yuan, B. Eckart, K. Kim, V. Jampani, D. Fox, J. Kautz, Deepgmr: Learning latent gaussian mixture models for registration, in: European conference on computer vision, Springer, 2020, pp. 733–750
work page 2020
-
[74]
Y. Wang, J. M. Solomon, Deep closest point: Learning representations for point cloud registration, in: Proceedings of the IEEE/CVF interna- tional conference on computer vision, 2019, pp. 3523–3532
work page 2019
-
[75]
W. Lu, G. Wan, Y. Zhou, X. Fu, P. Yuan, S. Song, Deepvcp: An end-to- end deep neural network for point cloud registration, in: Proceedings of the IEEE/CVF international conference on computer vision, 2019, pp. 12–21
work page 2019
-
[76]
H. Xu, N. Ye, G. Liu, B. Zeng, S. Liu, Finet: Dual branches feature interaction for partial-to-partial point cloud registration, in: Proceed- ings of the AAAI Conference on Artificial Intelligence, Vol. 36, 2022, pp. 2848–2856
work page 2022
-
[77]
Z. Qin, H. Yu, C. Wang, Y. Guo, Y. Peng, S. Ilic, D. Hu, K. Xu, Geo- transformer: Fast and robust point cloud registration with geometric transformer, IEEE Transactions on Pattern Analysis and Machine In- telligence 45 (8) (2023) 9806–9821
work page 2023
-
[78]
H. Deng, T. Birdal, S. Ilic, Ppf-foldnet: Unsupervised learning of ro- tation invariant 3d local descriptors, in: Proceedings of the European conference on computer vision (ECCV), 2018, pp. 602–618. 37
work page 2018
-
[79]
G. Mei, H. Tang, X. Huang, W. Wang, J. Liu, J. Zhang, L. Van Gool, Q. Wu, Unsupervised deep probabilistic approach for partial point cloud registration, in: ProceedingsoftheIEEE/CVFConferenceonComputer Vision and Pattern Recognition, 2023, pp. 13611–13620
work page 2023
- [80]
discussion (0)