REVIEW 2 major objections 1 minor 18 references
Clinical Risk-Aware Multi-Level Grading for Coronary Artery Stenosis through Curved Feature Reconstruction
T0 review · 2 major / 1 minor · reviewed 2026-06-30 · grok-4.3
Pith's one-line read Vessel curve priors enable point-by-point fusion of CCTA and 3D SCPR features for multi-level coronary stenosis grading when paired with risk-aware loss.
desk verdict The CFR module tries to fuse CCTA and SCPR via curve-based point correspondence while the CR loss adds risk weighting, but the alignment step looks fragile and the evidence is limited to one in-house set. read the letter →
The pith
A machine-rendered reading of the paper's core claim, the machinery that carries it, and where it could break.
The reading
What carries the argument
The Curved Feature Reconstruction (CFR) module, which uses vessel curves as prior and a point-by-point correspondence strategy to align and fuse features from CCTA and 3D SCPR images.
What would settle it
An external validation set from a second hospital where the method is applied to fresh CCTA and 3D SCPR pairs and its grading accuracy and risk alignment are compared against the same baseline methods.
Extended reading notes
Core claim
The central claim is that the CFR module, by using vessel curves as prior and a point-by-point correspondence strategy to precisely align and fuse features from CCTA and 3D SCPR images, together with the CR Loss that incorporates clinical risk relevance into network training, produces multi-level stenosis grades that align better with clinical diagnosis than prior methods.
Load-bearing premise
Vessel curves extracted from the images remain accurate enough to produce reliable point-by-point feature correspondence even when real clinical vessels are tortuous or images contain distortions.
Editorial extensions
If this is right
- Fused features from the two modalities overcome the separate shortcomings of tortuosity and distortion.
- The risk-aware loss produces grades that better match how clinicians weigh different stenosis severities.
- The full pipeline outperforms standard grading networks on the in-house dataset.
- Ablation results isolate the contribution of the correspondence strategy and the risk term.
Reading between the lines
- If the curve-based correspondence generalizes, the same alignment idea could be tested on other tubular structures such as airways or peripheral vessels.
- The approach implicitly assumes the in-house data distribution is representative; performance on data from different scanners or patient demographics would test that assumption directly.
- Integration into existing CCTA workflows would require checking whether the added reconstruction step increases or decreases overall reading time for radiologists.
Editorial analysis
A structured set of objections, weighed in public.
Referee Report
Summary. The manuscript proposes a multi-level grading model for coronary artery stenosis that combines CCTA and 3D SCPR imaging. It introduces a Curved Feature Reconstruction (CFR) module that uses vessel curves as prior to perform point-by-point correspondence for feature alignment and fusion, together with a Clinical Risk-Aware (CR) Loss that incorporates clinical risk relevance during training. Experiments on an in-house dataset are reported to show significant outperformance over competing methods, with ablation studies supporting the contribution of the proposed components.
Significance. If the reported gains are reproducible and the feature correspondence is verifiably accurate, the approach could improve automated stenosis grading by mitigating limitations of single-modality inputs and by producing risk-aligned predictions, which would be clinically relevant for coronary artery disease diagnosis.
major comments (2)
- [CFR module (method description)] The central performance claim rests on the CFR module producing semantically corresponding fused features. The abstract and method description state that vessel curves enable precise point-by-point alignment, yet no independent quantitative check of alignment fidelity (e.g., landmark registration error, warped-feature overlap, or visual inspection on tortuous vessels) is described. Without such evidence, gains cannot be confidently attributed to the module rather than to other factors or dataset artifacts.
- [Experiments and results] The experimental section asserts significant outperformance and effective ablations, but the supplied abstract supplies no numerical metrics, error bars, dataset size, patient count, exclusion criteria, or statistical tests. The full manuscript must include these details (and ideally external validation) for the outperformance claim to be evaluable.
minor comments (1)
- [Abstract] Abstract contains the grammatical error 'a in-house dataset' (should be 'an in-house dataset').
Simulated Author's Rebuttal
We thank the referee for the constructive comments. We address each major comment below and outline planned revisions where appropriate.
read point-by-point responses
-
Referee: [CFR module (method description)] The central performance claim rests on the CFR module producing semantically corresponding fused features. The abstract and method description state that vessel curves enable precise point-by-point alignment, yet no independent quantitative check of alignment fidelity (e.g., landmark registration error, warped-feature overlap, or visual inspection on tortuous vessels) is described. Without such evidence, gains cannot be confidently attributed to the module rather than to other factors or dataset artifacts.
Authors: We agree that an independent quantitative verification of alignment fidelity would strengthen attribution of gains specifically to the CFR module. In the revised manuscript we will add visual inspections of warped features on tortuous vessels together with quantitative overlap metrics derived from the vessel-curve prior to demonstrate point-by-point correspondence. revision: yes
-
Referee: [Experiments and results] The experimental section asserts significant outperformance and effective ablations, but the supplied abstract supplies no numerical metrics, error bars, dataset size, patient count, exclusion criteria, or statistical tests. The full manuscript must include these details (and ideally external validation) for the outperformance claim to be evaluable.
Authors: The full manuscript already reports dataset size, patient counts, exclusion criteria, numerical metrics with standard deviations, and statistical tests; these will be presented more prominently in the revision. External validation on independent cohorts is not feasible at present owing to the proprietary clinical nature of the data, but we have performed extensive internal cross-validation and ablation experiments to support reproducibility. revision: partial
Circularity Check
No significant circularity in derivation chain
full rationale
The paper proposes the CFR module (vessel-curve prior for point-by-point alignment of CCTA and 3D SCPR features) and CR Loss (clinical-risk weighting), then reports experimental outperformance on an in-house dataset plus ablations. No equations, fitted parameters, or self-citations are described that reduce any claimed prediction or uniqueness result to the inputs by construction. Performance claims rest on external method comparisons rather than internal redefinitions or self-referential fits, making the derivation self-contained.
Assumptions & free parameters
Cite this review
Pith. "Pith review of Clinical Risk-Aware Multi-Level Grading for Coronary Artery Stenosis through Curved Feature Reconstruction." pith.science (2026). https://pith.science/paper/XIE4Y7VY
@misc{pith2026260630082,
author = {Pith},
title = {Pith review of: Clinical Risk-Aware Multi-Level Grading for Coronary Artery Stenosis through Curved Feature Reconstruction},
year = {2026},
howpublished = {\url{https://pith.science/paper/XIE4Y7VY}},
note = {Machine review of arXiv:2606.30082}
}
read the original abstract
Developing a multi-level grading model for coronary artery stenosis holds great clinical significance for the diagnosis of coronary artery disease. However, designing an effective multi-level deep learning algorithm faces significant challenges. Specifically, utilizing CCTA or 3D SCPR images alone presents inherent shortcomings: CCTA images are difficult to analyze due to the tortuous paths of blood vessels, while 3D SCPR images are prone to abnormal distortions that hinder accurate grading. Furthermore, different stenosis grades are associated with varying clinical risks, and incorporating this association into the algorithm is non-trivial. To address the former problems, we propose the Curved Feature Reconstruction (CFR) module, which uses vessel curves as prior and employs a point-by-point correspondence strategy to precisely align and fuse features from both 3D SCPR and CCTA images. Meanwhile, a Clinical Risk-Aware (CR) Loss is employed to introduce clinical risk relevance into the network training so that the algorithm can better align with the clinical diagnosis. The experimental results on a in-house dataset reveal that our approach significantly outperforms other methods, and several ablation studies also demonstrate the effectiveness of our proposed designs.
Figures
Reference graph
Works this paper leans on
-
[1]
Ricardo C Cury, Jonathon Leipsic, Suhny Abbara, Stephan Achenbach, Daniel Berman, Marcio Bittencourt, Matthew Budoff, Kavitha Chinnaiyan, Andrew D Choi, Brian Ghoshhajra, et al. Cad-rads 2.0–2022 coronary artery disease-reporting and data system: An expert consensus document of the society of cardiovascular computed tomography (scct), the american college...
2022
-
[2]
An Image is Worth 16x16 Words: Transformers for Image Recognition at Scale
Alexey Dosovitskiy, Lucas Beyer, Alexander Kolesnikov, Dirk Weissenborn, Xiaohua Zhai, Thomas Unterthiner, Mostafa Dehghani, Matthias Minderer, Georg Heigold, Sylvain Gelly, et al. An image is worth 16x16 words: Transformers for image recognition at scale.arXiv preprint arXiv:2010.11929,
work page Pith review arXiv 2010
-
[3]
Cost- sensitive regularization for diabetic retinopathy grading from eye fundus images
Adrian Galdran, Jose Dolz, Hadi Chakor, Herv´ e Lombaert, and Ismail Ben Ayed. Cost- sensitive regularization for diabetic retinopathy grading from eye fundus images. In Medical Image Computing and Computer Assisted Intervention – MICCAI 2020: 23rd International Conference, Lima, Peru, October 4–8, 2020, Proceedings, Part V, pages 665–674, Berlin, Heidelberg,
2020
-
[4]
Junjie Hou, Nianxi Liao, Jia Liu, Yuhang Liu, and Jianxing Qiu
URLhttps://doi.org/10.1007/978-3-030-59722-1_64. Junjie Hou, Nianxi Liao, Jia Liu, Yuhang Liu, and Jianxing Qiu. Learning disen- tangled representation for vessel-specific coronary artery calcium scoring. In2024 IEEE International Symposium on Biomedical Imaging (ISBI), pages 1–5,
-
[5]
https://doi.org/10.1109/ISBI56570.2024.10635440
doi: 10.1109/ISBI56570.2024.10635120. Rebekka Vibjerg Jensen, Marie Vognstoft Hjortbak, and Hans Erik Bøtker. Ischemic heart disease: an update. InSeminars in Nuclear Medicine, volume 50, pages 195–207. Elsevier,
-
[6]
VIS 2002., pages 37–44,
2002
-
[7]
Full Duplex Hybrid A/D Beamforming with Reduced Complexity Multi-Tap Analog Cancellation
doi: 10.1109/ VISUAL.2002.1183754. B Michael Kelm, Sushil Mittal, Yefeng Zheng, Alexey Tsymbal, Dominik Bernhardt, Fer- nando Vega-Higuera, S Kevin Zhou, Peter Meer, and Dorin Comaniciu. Detection, grad- ing and classification of coronary stenoses in computed tomography angiography. In International Conference on Medical Image Computing and Computer-Assis...
work page Pith review arXiv 2002
-
[8]
Decoupled Weight Decay Regularization
Ilya Loshchilov and Frank Hutter. Decoupled weight decay regularization.arXiv preprint arXiv:1711.05101,
Show all 18 references
-
[9]
Spatio-temporal contrast network for data- efficient learning of coronary artery disease in coronary CT angiography
Xinghua Ma, Mingye Zou, Xinyan Fang, Yang Liu, Gongning Luo, Wei Wang, Kuanquan Wang, Zhaowen Qiu, Xin Gao, and Shuo Li. Spatio-temporal contrast network for data- efficient learning of coronary artery disease in coronary CT angiography. In Marius George Linguraru, Qi Dou, Aas...
2024
-
[10]
doi: 10.1007/978-3-031-72120-5\
-
[11]
Xinghua Ma, Xinyan Fang, Mingye Zou, Gongning Luo, Wei Wang, Kuanquan Wang, Zhaowen Qiu, Xin Gao, and Shuo Li
URLhttps://doi.org/ 10.1007/978-3-031-72120-5_60. Xinghua Ma, Xinyan Fang, Mingye Zou, Gongning Luo, Wei Wang, Kuanquan Wang, Zhaowen Qiu, Xin Gao, and Shuo Li. A trusted lesion-assessment network for inter- pretable diagnosis of coronary artery disease in coronary CT angiogra...
2025 doi
-
[12]
URLhttps://doi.org/10.1609/aaai.v39i6.32642
doi: 10.1609/AAAI.V39I6.32642. URLhttps://doi.org/10.1609/aaai.v39i6.32642. 12 Clinical Risk-A ware Grading for Coronary Artery Stenosis Graham Mowatt, Jonathan A Cook, Graham S Hillis, Shonagh Walker, Cynthia Fraser, Xueli Jia, and Norman Waugh. 64-slice computed tomography a...
-
[13]
Kenichiro Otsuka, Shota Fukuda, Atsushi Tanaka, Koki Nakanishi, Haruyuki Taguchi, Ju- nichi Yoshikawa, Kenei Shimada, and Minoru Yoshiyama
doi: 10.1109/CVPR.2016.532. Kenichiro Otsuka, Shota Fukuda, Atsushi Tanaka, Koki Nakanishi, Haruyuki Taguchi, Ju- nichi Yoshikawa, Kenei Shimada, and Minoru Yoshiyama. Napkin-ring sign on coronary ct angiography for the prediction of acute coronary syndrome.JACC: Cardiovascula...
2016 doi
-
[14]
Pointscatter: Point set representation for tubular structure extraction
Dong Wang, Zhao Zhang, Ziwei Zhao, Yuhang Liu, Yihong Chen, and Liwei Wang. Pointscatter: Point set representation for tubular structure extraction. InComputer Vision – ECCV 2022: 17th European Conference, Tel Aviv, Israel, October 23–27, 2022, Proceedings, Part XXI, pages 366...
2022
- [15]
-
[16]
Coronary r-cnn: Vessel-wise method for coronary artery lesion detection and analysis in coronary ct angiography
Yu Zhang, Jun Ma, and Jing Li. Coronary r-cnn: Vessel-wise method for coronary artery lesion detection and analysis in coronary ct angiography. In Linwei Wang, Qi Dou, P. Thomas Fletcher, Stefanie Speidel, and Shuo Li, editors,Medical Image Computing and Computer Assisted Inte...
2022
-
[17]
ISBN 978-3-031-16437-8
Springer Nature Switzerland. ISBN 978-3-031-16437-8. Zhixing Zhang, Ziwei Zhao, Dong Wang, Shishuang Zhao, Yuhang Liu, Jia Liu, and Liwei Wang. Topology-preserving automatic labeling of coronary arteries via anatomy-aware connection classifier. In Hayit Greenspan, Anant Madabh...
2023
-
[18]
doi: 10.1109/CVPR52734.2025.02877
IEEE Computer Society. doi: 10.1109/CVPR52734.2025.02877. URL https://doi.ieeecomputersociety.org/10.1109/CVPR52734.2025.02877. Majd Zreik, Robbert W Van Hamersvelt, Jelmer M Wolterink, Tim Leiner, Max A Viergever, and Ivana Iˇ sgum. A recurrent cnn for automatic detection and...
2025 doi
Reviewed June 30, 2026 · model on record in the stance chip above.
Discussion (0). Continue with ORCID to comment.