REVIEW 2 major objections 2 minor 26 references
AnF-DiffPET: Anatomy- and Frequency-Guided Diffusion for PET/CT Denoising
T0 review · 2 major / 2 minor · reviewed 2026-07-02 · grok-4.3
Pith's one-line read An anatomy- and frequency-guided diffusion model recovers high-dose PET images from low-dose inputs using CT conditioning.
desk verdict AnF-DiffPET adds three named modules to a CT-conditioned diffusion denoiser for low-dose PET, but the abstract gives no ablations so we cannot tell what actually drives the gains. read the letter →
The pith
A machine-rendered reading of the paper's core claim, the machinery that carries it, and where it could break.
The reading
What carries the argument
Anatomical-Frequency Guidance (AFG) that modulates diffusion features using both CT-derived anatomical structure and frequency-domain information to steer the denoising trajectory.
What would settle it
An ablation experiment that removes AFG, MSCTR, and FCHM one at a time and finds no measurable drop in PSNR, SSIM, or SUV error on the same test sets would falsify the claim that these modules are the primary source of improvement.
Extended reading notes
Core claim
The AnF-DiffPET framework integrates Anatomical-Frequency Guidance (AFG), Multi-Scale Cross-Transformer Reconstruction (MSCTR), and Frequency-Contrastive Hard Mining (FCHM) into a CT-conditioned diffusion process to recover high-dose PET images from low-dose inputs, achieving improved fidelity, anatomical consistency, and quantitative accuracy.
Load-bearing premise
The reported gains are driven mainly by the three added modules rather than by the underlying diffusion training procedure or by tuning choices specific to the four evaluation datasets.
Editorial extensions
If this is right
- Low-dose PET acquisitions can retain higher anatomical fidelity and more reliable tracer uptake values than with prior CNN or GAN denoisers.
- CT conditioning becomes a practical source of anatomical and frequency guidance inside diffusion-based medical image restoration.
- Frequency-domain contrastive mining reduces artifacts that standard diffusion models produce when recovering fine uptake patterns.
- Multi-scale cross-transformer blocks stabilize feature propagation across the denoising steps at different resolutions.
Reading between the lines
- The same guidance pattern could be tested on SPECT or MRI denoising where paired anatomical images are available.
- If the modules prove robust, clinical protocols could lower injected activity further while preserving diagnostic quantification.
- The frequency-contrastive component might generalize to other inverse problems that suffer from band-limited noise.
Editorial analysis
A structured set of objections, weighed in public.
Referee Report
Summary. The paper introduces AnF-DiffPET, a CT-conditioned diffusion model for low-dose PET denoising that integrates three modules—Anatomical-Frequency Guidance (AFG), Multi-Scale Cross-Transformer Reconstruction (MSCTR), and Frequency-Contrastive Hard Mining (FCHM)—to address insufficient anatomical guidance, unstable multi-scale propagation, and frequency-domain uptake recovery. It reports improved image fidelity, anatomical consistency, and quantitative metrics over CNN-, GAN-, transformer-, and diffusion-based baselines across four PET/CT datasets, with code and models to be released publicly.
Significance. If the reported gains prove robust and attributable to the proposed modules rather than base diffusion training, the work could meaningfully advance conditional diffusion approaches for medical image denoising by explicitly incorporating anatomy and frequency constraints, with downstream value for dose reduction in PET imaging. The commitment to public code release supports reproducibility and follow-on work.
major comments (2)
- [Experiments] Experiments section: the central claim that AFG, MSCTR, and FCHM drive the observed gains in fidelity and consistency rests on comparisons to external baselines only; without ablation tables that isolate each module (e.g., full model vs. diffusion backbone alone, or successive addition of AFG/MSCTR/FCHM), attribution remains unverified and the improvements could arise from training protocol or dataset tuning instead.
- [Experiments] Quantitative results (Tables 2–4): no error bars, standard deviations across runs, or statistical significance tests (e.g., paired t-tests or Wilcoxon) are reported for the metric improvements; this leaves open whether the gains over diffusion baselines survive proper testing and undermines the quantitative-fidelity claim.
minor comments (2)
- [Abstract] Abstract and §1: the phrasing “frequency domain uptake recovery” is used without a brief definition or reference to the specific frequency bands or transforms employed; a short clarification would aid readers unfamiliar with frequency-guided diffusion.
- The manuscript states that code will be released upon acceptance; confirming a specific repository link or DOI in the camera-ready version would strengthen the reproducibility claim.
Simulated Author's Rebuttal
We thank the referee for the constructive comments on our manuscript. We address each major comment point by point below and will revise the manuscript to strengthen the experimental validation.
read point-by-point responses
-
Referee: [Experiments] Experiments section: the central claim that AFG, MSCTR, and FCHM drive the observed gains in fidelity and consistency rests on comparisons to external baselines only; without ablation tables that isolate each module (e.g., full model vs. diffusion backbone alone, or successive addition of AFG/MSCTR/FCHM), attribution remains unverified and the improvements could arise from training protocol or dataset tuning instead.
Authors: We agree that internal ablation studies are required to attribute gains specifically to AFG, MSCTR, and FCHM rather than other factors. The original submission emphasized external baseline comparisons; we will add ablation tables in the revision showing the base diffusion backbone alone and the effects of successively incorporating each proposed module. revision: yes
-
Referee: [Experiments] Quantitative results (Tables 2–4): no error bars, standard deviations across runs, or statistical significance tests (e.g., paired t-tests or Wilcoxon) are reported for the metric improvements; this leaves open whether the gains over diffusion baselines survive proper testing and undermines the quantitative-fidelity claim.
Authors: We concur that variability measures and statistical tests are essential for robust quantitative claims. The revised manuscript will report standard deviations across multiple independent runs via error bars and include paired t-tests (or Wilcoxon signed-rank tests where appropriate) to assess statistical significance of improvements over diffusion baselines. revision: yes
Circularity Check
No derivation chain present; purely empirical DL method
full rationale
The paper describes a diffusion-based neural network architecture with three proposed modules (AFG, MSCTR, FCHM) and reports empirical gains on four datasets versus baselines. No mathematical derivation, first-principles result, or predictive equation is claimed or present. Performance numbers are obtained by training and evaluating on the datasets, which is standard empirical practice and does not constitute a derivation that reduces to its inputs by construction. Self-citations, if any, are not load-bearing for any claimed derivation.
Assumptions & free parameters
Cite this review
Pith. "Pith review of AnF-DiffPET: Anatomy- and Frequency-Guided Diffusion for PET/CT Denoising." pith.science (2026). https://pith.science/paper/4VBCBFSV
@misc{pith2026260700509,
author = {Pith},
title = {Pith review of: AnF-DiffPET: Anatomy- and Frequency-Guided Diffusion for PET/CT Denoising},
year = {2026},
howpublished = {\url{https://pith.science/paper/4VBCBFSV}},
note = {Machine review of arXiv:2607.00509}
}
read the original abstract
Positron emission tomography (PET) provides essential functional information for disease assessment, however reducing injected activity or acquisition time produces low-dose (LD) PET with stronger count dependent noise and less reliable uptake quantification. Diffusion models offer a promising solution for PET denoising by progressively recovering high-dose (HD) PET images from LD inputs. However, LD-to-HD PET denoising is still challenging due to insufficient anatomical guidance, unstable multi-scale feature propagation, and uncertain frequency domain uptake recovery. We propose AnF-DiffPET, an anatomy- and frequency-guided diffusion framework for computed tomography (CT) conditioned LD PET denoising. The framework integrates Anatomical-Frequency Guidance (AFG), Multi-Scale Cross-Transformer Reconstruction (MSCTR), and Frequency-Contrastive Hard Mining (FCHM) to enhance anatomy aware feature modulation and frequency domain consistency during denoising. Experimental results across four PET/CT datasets show that the proposed method improves image fidelity, anatomical consistency, and quantitative fidelity over representative CNN-based, GAN-based, transformer-based, and diffusion-based methods. The code and trained models will be publicly released upon acceptance.
Figures
Figures from the paper (5 more)
Reference graph
Works this paper leans on
-
[1]
G. K. von Schulthess, H. C. Steinert, T. F. Hany, Integrated pet/ct: current applications and future directions, Radiol- ogy 238 (2) (2006) 405–422
work page 2006
-
[2]
S. Basu, T. C. Kwee, S. Surti, E. A. Akin, D. Yoo, A. Alavi, Fundamentals of pet and pet/ct imaging, Annals of the New York Academy of Sciences 1228 (1) (2011) 1–18
work page 2011
-
[3]
T. M. Blodgett, C. C. Meltzer, D. W. Townsend, Pet/ct: form and function, Radiology 242 (2) (2007) 360–385
work page 2007
-
[4]
X. Tian, S. Chen, Y . Wang, D. Han, Y . Lin, J. Zhao, J.- C. Chen, Deep residual-in-residual model-based pet im- age super-resolution with motion blur, Electronics 13 (13) (2024) 2582
work page 2024
- [5]
-
[6]
Z. Yang, Y . Zhou, H. Chen, H. Zhang, D. Zhao, B. Wei, Y . Xu, Unipet: A universal network for high-quality pet image denoising across varied dose reduction factors, Medical Image Analysis (2026) 104059
work page 2026
-
[7]
C. D. Pain, G. F. Egan, Z. Chen, Deep learning-based image reconstruction and post-processing methods in positron emission tomography for low-dose imaging and resolution enhancement, European Journal of Nuclear Medicine and Molecular Imaging 49 (9) (2022) 3098–
work page 2022
-
[8]
doi:10.1007/s00259-022-05746-4
Show all 26 references
-
[9]
A. M. Alessio, P. E. Kinahan, T. K. Lewellen, Model- ing and incorporation of system response functions in 3-d whole body pet, IEEE transactions on medical imaging 25 (7) (2006) 828–837
2006
-
[10]
Cloquet, F
C. Cloquet, F. Sureau, M. Defrise, G. Van Simaeys, N. Trotta, S. Goldman, Non-gaussian space-variant res- olution modelling for list-mode reconstruction, Physics in Medicine & Biology 55 (17) (2010) 5045–5066
2010
-
[11]
J. Kim, J. K. Lee, K. M. Lee, Accurate image super- resolution using very deep convolutional networks, in: Proceedings of the IEEE conference on computer vision and pattern recognition, 2016, pp. 1646–1654
2016
-
[12]
B. Lim, S. Son, H. Kim, S. Nah, K. Mu Lee, Enhanced deep residual networks for single image super-resolution, in: Proceedings of the IEEE conference on computer vi- sion and pattern recognition workshops, 2017, pp. 136– 144
2017
-
[13]
X. Wang, K. Yu, S. Wu, J. Gu, Y . Liu, C. Dong, Y . Qiao, C. C. Loy, ESRGAN: Enhanced super-resolution gener- ative adversarial networks, in: Proceedings of the Eu- ropean Conference on Computer Vision (ECCV) Work- shops, 2018. 10
2018
-
[14]
X. Chen, Y . Qiu, W. Liang, G. Zhou, S. Xie, Spatial infor- mation regularized tensor decomposition framework for super-resolution reconstruction of medical mri and radio- graphs, IEEE Transactions on Computational Imaging 8 (2022) 865–878
2022
-
[15]
J. Cui, Y . Xie, N. Guo, Y . Feng, Q. Li, Pet image denoising using consistent denoising diffusion model (2024)
2024
-
[16]
Liang, J
J. Liang, J. Cao, G. Sun, K. Zhang, L. Van Gool, R. Timo- fte, SwinIR: Image restoration using swin transformer, in: Proceedings of the IEEE/CVF International Conference on Computer Vision Workshops, 2021, pp. 1833–1844
2021
-
[17]
J. Ho, A. Jain, P. Abbeel, Denoising diffusion probabilistic models, Advances in neural information processing sys- tems 33 (2020) 6840–6851
2020
-
[18]
S. Pan, T. Wang, R. L. Qiu, M. Axente, C.-W. Chang, J. Peng, A. B. Patel, J. Shelton, S. A. Patel, J. Roper, et al., 2d medical image synthesis using transformer-based de- noising diffusion probabilistic model, Physics in Medicine & Biology 68 (10) (2023) 105004
2023
-
[19]
G.-H. Liu, A. Vahdat, D.-A. Huang, E. A. Theodorou, W. Nie, A. Anandkumar, I2SB: Image-to-image schrödinger bridge, arXiv preprint arXiv:2302.05872 (2023)
2023
-
[20]
J. Liu, Q. Wang, H. Fan, Y . Wang, Y . Tang, L. Qu, Resid- ual denoising diffusion models, in: Proceedings of the IEEE/CVF Conference on Computer Vision and Pattern Recognition, 2024, pp. 2773–2783
2024
-
[21]
Y . Li, Y . Wu, Y . Lai, M. Hu, X. Yang, Meddinov3: How to adapt vision foundation models for medical image seg- mentation?, arXiv preprint arXiv:2509.02379 (2025)
2025
-
[22]
Saeed, S
N. Saeed, S. Hassan, S. Hardan, A. Aly, D. Taratynova, et al., A multimodal and multi-centric head and neck cancer dataset for segmentation, diagnosis and out- come prediction, hECKTOR 2025 dataset paper (2025). arXiv:2509.00367, doi:10.48550/arXiv.2509.00367. URLhttps://arxiv...
2025 doi
-
[23]
Jeblick, B
K. Jeblick, B. Schachtner, A. Mittermeier, J. Dexl, P. Wesp, T. Küstner, S. Gatidis, et al., A whole-body psma-pet/ct dataset with manually annotated tumor lesions (2026). doi:10.7937/R7EP-3X37. URLhttps://www.cancerimagingarchive.net/ collection/PSMA-PET-CT-Lesions/
2026 doi
-
[24]
K. A. Kurdziel, A. B. Apolo, L. Lindenberg, E. Mena, Y . Y . McKinney, S. S. Adler, B. Turk- bey, et al., Data from naf prostate (2015). doi:10.7937/K9/TCIA.2015.ISOQTHKO. URLhttps://www.cancerimagingarchive.net/ collection/naf-prostate/
2015 doi
-
[25]
P. Muzi, M. Wanner, P. Kinahan, Data from rider lung pet-ct (2015). doi:10.7937/K9/TCIA.2015.OFIP7TVM. URLhttps://www.cancerimagingarchive.net/ collection/rider-lung-pet-ct/
2015 doi
-
[26]
Z. Han, Y . Wang, L. Zhou, P. Wang, B. Yan, J. Zhou, Y . Wang, D. Shen, Contrastive diffusion model with auxil- iary guidance for coarse-to-fine pet reconstruction (2023). arXiv:2308.10157. URLhttps://arxiv.org/abs/2308.10157 11
2023