REVIEW 4 major objections 5 minor 46 references
EndoMD-SLAM: Endoscopic Gaussian Splatting SLAM under Optical Degradation with Memory and Static-Transient Decomposition
T0 review · 4 major / 5 minor · reviewed 2026-08-14 · deepseek-v4-flash
Pith's one-line read EndoMD-SLAM keeps colonoscopy mapping stable under lens contamination by gating map updates and separating transient artifacts from the anatomical field.
desk verdict EndoMD-SLAM tackles a real, under-addressed failure mode in endoscopic 3DGS SLAM with a sensible gated-memory plus static-transient decomposition design, but the evaluation is too thin to fully trust the headline numbers. read the letter →
The pith
A machine-rendered reading of the paper's core claim, the machinery that carries it, and where it could break.
The reading
What carries the argument
The load-bearing object is a paired trust-and-factorization mechanism: the reliability gate and the static-transient Gaussian fields. The gate is $g_t=\mathbb{I}(\rho_t\ge\tau_\rho \wedge N_{\mathrm{valid}}\ge\tau_n)$, where $\rho_t$ and $N_{\mathrm{valid}}$ come from a weighted Procrustes pose solve on foundation-model correspondences, with weights $w'_i=w_i\max(1-\hat{\alpha}^t_{t-1}(u_i),0)^\gamma$ modulated by the rendered transient opacity. When $g_t=1$ the static map is updated; when $g_t=0$ map updates are suspended, degraded frames are allowed transient-only fitting, and the pose is recovered by selecting the memory-bank keyframe with the highest geometric consensus $\rho_t^{(k)}$. The representation is two Gaussian fields composited as $\hat{I}_t=\hat{I}^t_t+(1-\hat{\alpha}^t_t)\odot\hat{I}^s_t$, with regularization pushing transient occupancy up and static emptiness down. Together these keep corrupted poses and camera-attached artifacts from entering the persistent anatomy.
What would settle it
Render synthetic water droplets and debris with known ground-truth masks onto clean colonoscopy frames with known poses, run EndoMD-SLAM with and without the transient-alpha weighting, and compare the predicted transient field against the known masks. If the predicted mask has low overlap with the true contamination yet the trajectory error stays near 3 mm, or if removing the weighting leaves the pose error nearly unchanged, then the decomposition is not the active ingredient and the memory gate is carrying the result.
Extended reading notes
Core claim
The paper's central discovery is that the two failure modes induced by optical degradation—tracking drift during flushing and irreversible fusion of droplets into geometry—are both consequences of the SLAM system treating every observation as reliable new anatomy. The fix is to make trust explicit and to split the representation. A binary reliability gate, computed from the fraction of geometrically valid correspondences after weighting by the transient opacity mask, decides whether a frame may write into the static map; when the gate closes, the system suspends static updates and relocalizes using candidate keyframes retrieved from a temporal memory bank. In parallel, the scene is represented as two Gaussian fields—a global static field for anatomy and a per-frame transient field for contaminants—composited by occlusion-style alpha blending, so the optimization can reproduce the degraded view while the static field stays clean. The paper's reported outcome of this design is an ATE of 3.02 mm and PSNR of 18.06 dB on the degraded benchmark, against 35.91 mm and 8.16 dB for the endoscopy-specific baseline it aims to replace.
Load-bearing premise
The whole tracking chain assumes that, after the transient mask has down-weighted contaminated regions, the learned matcher still finds enough correct 3D point pairs on smooth, texture-poor colon walls to recover the pose; the paper reports no direct measurement of mask accuracy or surviving correspondence density on clean tissue.
Editorial extensions
If this is right
- If the central claim holds, a dense colonoscopy SLAM system can survive repeated lens flushing and droplet occlusion without accumulating pose error, which is the precondition for using live 3D reconstruction as a navigation aid.
- Frames deemed unreliable are never written into the static map, so degraded intervals cannot permanently corrupt the anatomy; the final reconstruction remains usable for documentation even when the source video is badly contaminated.
- Because the scene is factored into static and transient fields, the same model can render both a clean anatomical view and the true degraded view, giving the clinician both representations at once.
- The transient field is recycled per-frame, so the cost of artifact handling does not grow with the number of contamination events, keeping mapping time nearly flat over a long procedure.
Reading between the lines
- The paper evaluates on the C3VDv2 benchmark only and states that strictly real-time clinical deployment remains future work; at 0.95 FPS the current system is not yet live-grade, and generalizing to real colonoscopy video is untested.
- A diagnostic the authors do not run is to measure the transient field against ground-truth contamination masks; the method's logic predicts that mask accuracy should track pose accuracy, and that correlation would isolate which component produces the gain.
- The same gating-plus-decomposition pattern should transfer to other camera-attached distractors in surgery, such as smoke, blood, or tool occlusion, because the transient field is agnostic to what it absorbs; this is an editorial extension.
- The reported results assume RGB-D input, and the transient field is initialized by backprojecting depth, so in a monocular deployment the accuracy of the depth prior would likely bound how cleanly small contaminants are separated.
Signed reviews
Editorial analysis
A structured set of objections, weighed in public.
Referee Report
Summary. The paper proposes EndoMD-SLAM, a 3D Gaussian Splatting SLAM system for colonoscopy under optical degradation. The method combines a temporal memory bank that gates static map updates and triggers relocalization when tracking is unreliable, with a static-transient Gaussian decomposition that separates persistent anatomy from camera-attached contaminants. The paper curates a ten-sequence benchmark from C3VDv2 with 'water on lens' and 'debris on lens' metadata, and reports that EndoMD-SLAM achieves an ATE of 3.02 mm and PSNR of 18.06 dB, outperforming NICE-SLAM, MonoGS, and EndoGSLAM, with an ablation study attributing the gains to both the memory and the decomposition modules.
Significance. The problem addressed is important and clinically relevant: standard dense SLAM systems do fail when lens contamination and water flushing violate photometric consistency, and the proposed memory-gating plus static-transient decomposition is a sensible and well-motivated design. The curated degradation-focused benchmark is a useful resource, and the qualitative results suggest the method can prevent map corruption on the tested sequences. However, the experimental evidence as presented is not yet sufficient to support the central robustness claims: the ablation baseline is numerically identical to a competitor system, there are no error bars or per-sequence statistics, hyperparameters appear to be selected on the same ten sequences that are then used for evaluation, and the tracking pipeline's reliance on MASt3R correspondences plus a learned transient mask is not directly validated. With additional experiments and analysis these concerns are addressable; the core idea is defensible.
major comments (4)
- [Section IV-C, Table II] The row labelled 'Baseline' in Table II reports exactly the same numbers as EndoGSLAM in Table I (PSNR 8.16, SSIM 0.335, LPIPS 0.628, RMSE 26.21, ATE 35.91). Since EndoMD-SLAM is described as using a MASt3R-based foundation-model tracker in Section III-A-a, this row cannot be the proposed architecture without the memory and decomposition modules unless the authors are equating EndoMD-SLAM's baseline with EndoGSLAM. As written, the ablation does not isolate the contribution of the proposed components on the proposed architecture, and the conclusion that both components are 'critical' is not supported. Please re-run the ablation from the full EndoMD-SLAM pipeline with each component removed and report the no-component baseline using the same tracker and mapping backbone.
- [Section IV-A-d, Table I] All reported metrics are aggregate numbers over ten sequences, with no per-sequence breakdown, standard deviation, or failure-case analysis. Moreover, the hyperparameters in Section IV-A-d (tau_rho=0.15, tau_n=500, gamma=2.0, N_t=1000, |C_t|=10, lambda_rgb=1.0, lambda_d=1.0, w_tr=0.01, w_bg=0.01) are listed without any validation procedure. If these thresholds and loss weights were tuned on the same ten sequences used in Table I, the headline margins (91% ATE reduction, 9.9 dB PSNR improvement) may partly reflect tuning on the test set. Please report per-sequence metrics, error bars, and either a held-out validation split or a sensitivity analysis over the key thresholds.
- [Section III-A-a, Eqs. (1)-(3)] The tracking chain rests entirely on MASt3R correspondences being re-weighted by the transient mask in Eq. (1), followed by weighted Procrustes in Eq. (2) and the reliability gate in Eq. (3). The paper provides no quantitative evidence that (a) MASt3R supplies enough metric 3D correspondences in textureless colon tissue, or (b) the transient mask suppresses the high-confidence matches that MASt3R assigns to moving lens contaminants. Without such evidence, the thresholds tau_rho=0.15 and tau_n=500 are unjustified and the robustness claim may not generalize beyond the ten curated sequences. Please report correspondence density, inlier fractions, mask-quality metrics (e.g., overlap of transient opacity with contaminant regions), and the distribution of rho and N_valid on clean versus degraded frames.
- [Section III-A-a and III-B] There is a circular dependency between tracking and decomposition: the transient mask used to re-weight correspondences in Eq. (1) is learned from poses produced by the same tracking loop, and the static map is updated only when the pose is deemed reliable. The paper does not explain how the transient field is initialized or maintained on severely degraded frames when the pose is gated out, nor does it analyze whether a wrong pose corrupts the mask and vice versa. Please describe the initialization procedure for degraded frames and provide an experiment that varies the transient-field initialization or uses a warm-start, so that the stability of the coupled loop can be assessed.
minor comments (5)
- [Abstract, Section IV-B] The 91% ATE reduction and 9.9 dB PSNR improvement are relative to EndoGSLAM, which has the worst ATE among the compared baselines; please state the comparison baseline explicitly in the abstract to avoid over-generalization.
- [Section IV-A-d] The method uses RGB-D input, but the abstract and introduction describe the contribution as supporting clinical endoscopic navigation without noting this requirement; please state clearly that depth input is needed and discuss how this maps to available colonoscopy hardware.
- [Section III-B, Eq. (7)-(8)] The depth loss supervises only static geometry, but during lens contamination the measured depth itself may be corrupted; please clarify how the depth supervision handles degraded frames where the depth observation does not correspond to anatomy.
- [Section IV-D] There is a typo in Section IV-D: 'estimatsed' should be 'estimated'.
- [Figure 3] It would strengthen the paper to report a quantitative measure of transient-field separation, such as the fraction of transient opacity overlapping the contaminant regions, instead of relying only on qualitative visualizations.
Circularity Check
No significant circularity: the headline gains are empirical benchmark comparisons, not quantities derived from fitted inputs or self-citations.
full rationale
EndoMD-SLAM is an empirical SLAM system; there is no formal derivation chain whose conclusions are fixed by its assumptions. The headline ATE reduction (35.91 mm to 3.02 mm) and PSNR gain (8.16 to 18.06 dB) are measured against external baselines on the C3VDv2-derived benchmark, and the ablation attributes the gains to the proposed gating and decomposition. I find no step in which a reported quantity equals a fitted input or a cited result by construction. The tracking loop (Eqs. 1-2) uses MASt3R correspondences reweighted by the transient mask, and the transient field is initialized from depth backprojection (Eq. 9); this is a coupled bootstrapping optimization, not a tautology, and the paper explicitly defaults the mask to 1 before transient initialization. The reliability gate thresholds and loss weights are stated as implementation details, but the paper does not show they were selected by fitting to the reported metrics, so the evaluation concern is potential overfitting, not definitional circularity. One genuine evaluation weakness is that the 'Baseline' row in Table II is numerically identical to the EndoGSLAM row in Table I (8.16 PSNR, 26.21 RMSE, 35.91 ATE), even though EndoMD-SLAM uses a different MASt3R-based tracker; this undermines the component-level attribution but does not make the main benchmark comparison circular, because the full system is still independently evaluated against published baselines. I therefore find no significant circularity, and score 0.
Assumptions & free parameters
free parameters (11)
- reliability gate match fraction threshold tau_rho =
0.15
- reliability gate valid point threshold tau_n =
500
- transient weight modulation exponent gamma =
2.0
- transient Gaussians per frame N_t =
1000
- reconstruction loss weight lambda_rgb =
1.0
- depth loss weight lambda_d =
1.0
- transient occupancy regularizer weight w_tr =
0.01
- static coverage regularizer weight w_bg =
0.01
- number of retrieval candidates |C_t| =
10
- transient recycling threshold tau_act =
not specified
- mapping iterations per frame =
25
assumptions (4)
- domain assumption C3VDv2 provides accurate depth and pose ground truth, and its metadata tags correctly identify degraded sequences.
- domain assumption MASt3R foundation model provides reliable 3D correspondences in textureless endoscopic images, and the transient mask can suppress contamination matches.
- domain assumption Camera-attached artifacts are well represented by a per-frame transient Gaussian field that does not entangle with static anatomy.
- domain assumption The colon tissue is static during mapping, aside from the transient artifacts.
invented entities (1)
-
Per-frame transient Gaussian field
Cite this review
Pith. "Pith review of EndoMD-SLAM: Endoscopic Gaussian Splatting SLAM under Optical Degradation with Memory and Static-Transient Decomposition." pith.science (2026). https://pith.science/paper/ZR4FFTHL
@misc{pith2026260808949,
author = {Pith},
title = {Pith review of: EndoMD-SLAM: Endoscopic Gaussian Splatting SLAM under Optical Degradation with Memory and Static-Transient Decomposition},
year = {2026},
howpublished = {\url{https://pith.science/paper/ZR4FFTHL}},
note = {Machine review of arXiv:2608.08949}
}
read the original abstract
Dense 3D reconstruction is critical for clinical endoscopic navigation and documentation. While Gaussian Splatting SLAM systems show promise in this domain, they fundamentally rely on strict multi-view photometric consistency. In routine procedures, this assumption is severely violated by intermittent optical degradations like moving debris and water flushing. Standard systems erroneously fuse these cameraattached artifacts into the persistent 3D geometry, causing severe tracking drift and irreversible map corruption. To address this limitation, we propose EndoMD-SLAM, a framework designed to maintain stability under optical degradation through specialized tracking and mapping mechanisms. On the tracking side, a memory-driven gating mechanism detects unreliable observations to suspend map updates and utilizes historical keyframes for drift-aware relocalization. On the mapping side, a self-supervised static-transient decomposition isolates visual contaminants into a dedicated transient field. This explicit separation prevents artifacts from structurally entangling with the persistent anatomical map. We curate a degradationfocused benchmark from colonoscopy videos to systematically evaluate these failure modes. Extensive experiments show that while standard baselines fail under severe optical degradation, EndoMD-SLAM preserves geometric integrity, reducing absolute trajectory error by 91% and improving rendering fidelity by 9.9 dB PSNR.
Figures
Figures from the paper (4 more)
Reference graph
Works this paper leans on
-
[1]
Ad- vances in real-time 3d reconstruction for medical endoscopy,
A. Richter, T. Steinmann, J.-C. Rosenthal, and S. J. Rupitsch, “Ad- vances in real-time 3d reconstruction for medical endoscopy,”Journal of imaging, vol. 10, no. 5, p. 120, 2024
work page 2024
-
[2]
Frontiers of robotic colonoscopy: A comprehensive review of robotic colonoscopes and technologies,
G. Ciuti, K. Skonieczna- ˙Zydecka, W. Marlicz, V . Iacovacci, H. Liu, D. Stoyanov, A. Arezzo, M. Chiurazzi, E. Toth, H. Thorlacius,et al., “Frontiers of robotic colonoscopy: A comprehensive review of robotic colonoscopes and technologies,”Journal of clinical medicine, vol. 9, no. 6, p. 1648, 2020
work page 2020
-
[3]
Endomapper dataset of complete calibrated endoscopy proce- dures,
P. Azagra, C. Sostres, ´A. Ferr ´andez, L. Riazuelo, C. Tomasini, O. L. Barbed, J. Morlana, D. Recasens, V . M. Batlle, J. J. G´omez-Rodr´ıguez, et al., “Endomapper dataset of complete calibrated endoscopy proce- dures,”Scientific Data, vol. 10, no. 1, p. 671, 2023
work page 2023
-
[4]
K. Wang, C. Yang, Y . Wang, S. Li, Y . Wang, Q. Dou, X. Yang, and W. Shen, “Endogslam: Real-time dense reconstruction and tracking in endoscopic surgeries using gaussian splatting,” inInternational Conference on Medical Image Computing and Computer-Assisted Intervention. Springer, 2024, pp. 219–229
work page 2024
-
[5]
Endoflow-slam: Real-time endoscopic slam with flow-constrained gaussian splatting,
T. Wu, Y . Miao, Z. Li, H. Zhao, K. Dang, J. Su, L. Yu, and H. Li, “Endoflow-slam: Real-time endoscopic slam with flow-constrained gaussian splatting,” inInternational Conference on Medical Image Computing and Computer-Assisted Intervention. Springer, 2025, pp. 202–212
work page 2025
-
[6]
Sage: slam with appearance and geometry prior for endoscopy,
X. Liu, Z. Li, M. Ishii, G. D. Hager, R. H. Taylor, and M. Unberath, “Sage: slam with appearance and geometry prior for endoscopy,” in 2022 International conference on robotics and automation (ICRA). IEEE, 2022, pp. 5587–5593
work page 2022
-
[7]
Coarse-to-fine real-time gs-slam from endoscopic rgbd data,
Z. Cao, Y . Zhang, Y . Qian, and Q. Wang, “Coarse-to-fine real-time gs-slam from endoscopic rgbd data,” inSeventeenth International Conference on Digital Image Processing (ICDIP 2025), vol. 13709. SPIE, 2025, pp. 210–219
work page 2025
-
[8]
Pr-endo: Physically based relightable gaus- sian splatting for endoscopy,
J. Kaleta, W. Smolak-Dy ˙zewska, D. Malarz, D. Dall’Alba, P. Ko- rzeniowski, and P. Spurek, “Pr-endo: Physically based relightable gaus- sian splatting for endoscopy,” inInternational Conference on Medical Image Computing and Computer-Assisted Intervention. Springer, 2025, pp. 391–401
work page 2025
Show all 46 references
-
[9]
Visual slam for handheld monocular endoscope,
O. G. Grasa, E. Bernal, S. Casado, I. Gil, and J. Montiel, “Visual slam for handheld monocular endoscope,”IEEE transactions on medical imaging, vol. 33, no. 1, pp. 135–146, 2013
2013
-
[10]
Slam based quasi dense reconstruction for min- imally invasive surgery scenes,
N. Mahmoud, A. Hostettler, T. Collins, L. Soler, C. Doignon, and J. M. M. Montiel, “Slam based quasi dense reconstruction for min- imally invasive surgery scenes,”arXiv preprint arXiv:1705.09107, 2017
2017 arXiv
-
[11]
Visual slam for bronchoscope tracking and bronchus reconstruction in bronchoscopic navigation,
C. Wang, M. Oda, Y . Hayashi, T. Kitasaka, H. Honma, H. Takabatake, M. Mori, H. Natori, and K. Mori, “Visual slam for bronchoscope tracking and bronchus reconstruction in bronchoscopic navigation,” in Medical Imaging 2019: Image-Guided Procedures, Robotic Interven- tions, and ...
2019
-
[12]
Sd-defslam: Semi-direct monocular slam for deformable and intracorporeal scenes,
J. J. G ´omez-Rodr´ıguez, J. Lamarca, J. Morlana, J. D. Tard´os, and J. M. Montiel, “Sd-defslam: Semi-direct monocular slam for deformable and intracorporeal scenes,” in2021 IEEE international conference on robotics and automation (ICRA). IEEE, 2021, pp. 5170–5177
2021
-
[13]
Oneslam to map them all: a generalized approach to slam for monocular endoscopic imaging based on tracking any point,
T. Teufel, H. Shu, R. D. Soberanis-Mukul, J. E. Mangulabnan, M. Sahu, S. S. Vedula, M. Ishii, G. Hager, R. H. Taylor, and M. Unberath, “Oneslam to map them all: a generalized approach to slam for monocular endoscopic imaging based on tracking any point,” International Journal ...
2024
-
[14]
Nerf: Representing scenes as neural radiance fields for view synthesis,
B. Mildenhall, P. P. Srinivasan, M. Tancik, J. T. Barron, R. Ramamoor- thi, and R. Ng, “Nerf: Representing scenes as neural radiance fields for view synthesis,”Communications of the ACM, vol. 65, no. 1, pp. 99–106, 2021
2021
-
[15]
3d gaussian splatting for real-time radiance field rendering
B. Kerbl, G. Kopanas, T. Leimk ¨uhler, G. Drettakis,et al., “3d gaussian splatting for real-time radiance field rendering.”ACM Trans. Graph., vol. 42, no. 4, pp. 139–1, 2023
2023
-
[16]
Risk of lens cloudiness during colorectal endoscopic submucosal dissection and ability of a novel lens cleaner to maintain and restore endoscopic view,
N. Yoshida, Y . Naito, R. Hirose, K. Ogiso, K. T. H. Siah, Y . Inada, O. Dohi, K. Kamada, K. Katada, K. Uchiyama,et al., “Risk of lens cloudiness during colorectal endoscopic submucosal dissection and ability of a novel lens cleaner to maintain and restore endoscopic view,”Dig...
2015
-
[17]
A novel lens cleaner to prevent water drop adhesions during colonoscopy and esophagogastroduodenoscopy,
N. Yoshida, Y . Naito, R. Yasuda, T. Murakami, K. Ogiso, R. Hirose, Y . Inada, O. Dohi, T. Okayama, K. Kamada,et al., “A novel lens cleaner to prevent water drop adhesions during colonoscopy and esophagogastroduodenoscopy,”Endoscopy international open, vol. 5, no. 12, pp. E123...
2017
-
[18]
C3vdv2–colonoscopy 3d video dataset with enhanced realism,
M. V . Golhar, L. S. G. Fretes, L. Ayers, V . S. Akshintala, T. L. Bobrow, and N. J. Durr, “C3vdv2–colonoscopy 3d video dataset with enhanced realism,”arXiv preprint arXiv:2506.24074, 2025
2025 arXiv
-
[19]
Orb-slam3: An accurate open-source library for visual, visual–inertial, and multimap slam,
C. Campos, R. Elvira, J. J. G. Rodr ´ıguez, J. M. Montiel, and J. D. Tard ´os, “Orb-slam3: An accurate open-source library for visual, visual–inertial, and multimap slam,”IEEE transactions on robotics, vol. 37, no. 6, pp. 1874–1890, 2021
2021
-
[20]
Cudasift-slam: Multiple-map visual slam for full procedure mapping in real human endoscopy,
R. Elvira, J. D. Tard ´os, and J. M. M. Montiel, “Cudasift-slam: Multiple-map visual slam for full procedure mapping in real human endoscopy,”arXiv preprint arXiv:2405.16932, 2024
2024 arXiv
-
[21]
Endo-depth-and-motion: Reconstruction and tracking in endoscopic videos using depth networks and photometric constraints,
D. Recasens, J. Lamarca, J. M. F ´acil, J. M. Montiel, and J. Civera, “Endo-depth-and-motion: Reconstruction and tracking in endoscopic videos using depth networks and photometric constraints,”IEEE Robotics and Automation Letters, vol. 6, no. 4, pp. 7225–7232, 2021
2021
-
[22]
Lightneus: Neural surface reconstruction in endoscopy using illumination de- cline,
V . M. Batlle, J. M. Montiel, P. Fua, and J. D. Tard ´os, “Lightneus: Neural surface reconstruction in endoscopy using illumination de- cline,” inInternational Conference on Medical Image Computing and Computer-Assisted Intervention. Springer, 2023, pp. 502–512
2023
-
[23]
3d densifica- tion for multi-map monocular vslam in endoscopy,
X. Anad ´on, J. Rodr ´ıguez-Puigvert, and J. Montiel, “3d densifica- tion for multi-map monocular vslam in endoscopy,”arXiv preprint arXiv:2503.14346, 2025
2025 arXiv
-
[24]
Mast3r-slam: Real- time dense slam with 3d reconstruction priors,
R. Murai, E. Dexheimer, and A. J. Davison, “Mast3r-slam: Real- time dense slam with 3d reconstruction priors,” in2025 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR). IEEE, 2025, pp. 16 695–16 705
2025
-
[25]
Vggt: Visual geometry grounded transformer,
J. Wang, M. Chen, N. Karaev, A. Vedaldi, C. Rupprecht, and D. Novotny, “Vggt: Visual geometry grounded transformer,” inPro- ceedings of the Computer Vision and Pattern Recognition Conference, 2025, pp. 5294–5306
2025
-
[26]
Depth anything 3: Recovering the visual space from any views,
H. Lin, S. Chen, J. Liew, D. Y . Chen, Z. Li, G. Shi, J. Feng, and B. Kang, “Depth anything 3: Recovering the visual space from any views,”arXiv preprint arXiv:2511.10647, 2025
2025 arXiv
-
[27]
Vggt-slam: Dense rgb slam optimized on the sl (4) manifold,
D. Maggio, H. Lim, and L. Carlone, “Vggt-slam: Dense rgb slam optimized on the sl (4) manifold,”arXiv preprint arXiv:2505.12549, 2025
2025 arXiv
-
[28]
Direct sparse odometry,
J. Engel, V . Koltun, and D. Cremers, “Direct sparse odometry,”IEEE transactions on pattern analysis and machine intelligence, vol. 40, no. 3, pp. 611–625, 2017
2017
-
[29]
Nfl-ba: Near-field light bundle adjustment for slam in dynamic lighting,
A. D. Beltran, D. Rho, M. Niethammer, and R. Sengupta, “Nfl-ba: Near-field light bundle adjustment for slam in dynamic lighting,”arXiv preprint arXiv:2412.13176, 2024
2024
-
[30]
Co-fusion: Real-time segmentation, tracking and fusion of multiple objects,
M. R ¨unz and L. Agapito, “Co-fusion: Real-time segmentation, tracking and fusion of multiple objects,” in2017 IEEE International Confer- ence on Robotics and Automation (ICRA). IEEE, 2017, pp. 4471– 4478
2017
-
[31]
Dg-slam: Robust dynamic gaussian splatting slam with hybrid pose optimization,
Y . Xu, H. Jiang, Z. Xiao, J. Feng, and L. Zhang, “Dg-slam: Robust dynamic gaussian splatting slam with hybrid pose optimization,” Advances in Neural Information Processing Systems, vol. 37, pp. 51 577–51 596, 2024
2024
-
[32]
Dgs-slam: Gaussian splatting slam in dynamic environment,
M. Kong, J. Lee, S. Lee, and E. Kim, “Dgs-slam: Gaussian splatting slam in dynamic environment,”arXiv preprint arXiv:2411.10722, 2024
2024 arXiv
-
[33]
Nr-slam: Nonrigid monocular slam,
J. J. G. Rodriguez, J. M. Montiel, and J. D. Tardos, “Nr-slam: Nonrigid monocular slam,”IEEE Transactions on Robotics, vol. 40, pp. 4252– 4264, 2024
2024
-
[34]
Free- surgs: Sfm-free 3d gaussian splatting for surgical scene reconstruc- tion,
J. Guo, J. Wang, D. Kang, W. Dong, W. Wang, and Y .-h. Liu, “Free- surgs: Sfm-free 3d gaussian splatting for surgical scene reconstruc- tion,” inInternational Conference on Medical Image Computing and Computer-Assisted Intervention. Springer, 2024, pp. 350–360
2024
-
[35]
Endogs: Deformable endoscopic tissues reconstruction with gaussian splat- ting,
L. Zhu, Z. Wang, J. Cui, Z. Jin, G. Lin, and L. Yu, “Endogs: Deformable endoscopic tissues reconstruction with gaussian splat- ting,” inInternational Conference on Medical Image Computing and Computer-Assisted Intervention. Springer, 2024, pp. 135–145
2024
-
[36]
Endo-4dgs: Endoscopic monocular scene reconstruction with 4d gaussian splatting,
Y . Huang, B. Cui, L. Bai, Z. Guo, M. Xu, M. Islam, and H. Ren, “Endo-4dgs: Endoscopic monocular scene reconstruction with 4d gaussian splatting,” inInternational Conference on Medical Image Computing and Computer-Assisted Intervention. Springer, 2024, pp. 197–207
2024
-
[37]
Nice-slam: Neural implicit scalable encoding for slam,
Z. Zhu, S. Peng, V . Larsson, W. Xu, H. Bao, Z. Cui, M. R. Oswald, and M. Pollefeys, “Nice-slam: Neural implicit scalable encoding for slam,” inProceedings of the IEEE/CVF conference on computer vision and pattern recognition, 2022, pp. 12 786–12 796
2022
-
[38]
Point- slam: Dense neural point cloud-based slam,
E. Sandstr ¨om, Y . Li, L. Van Gool, and M. R. Oswald, “Point- slam: Dense neural point cloud-based slam,” inProceedings of the IEEE/CVF international conference on computer vision, 2023, pp. 18 433–18 444
2023
-
[39]
Gaussian splatting slam,
H. Matsuki, R. Murai, P. H. Kelly, and A. J. Davison, “Gaussian splatting slam,” inProceedings of the IEEE/CVF conference on computer vision and pattern recognition, 2024, pp. 18 039–18 048
2024
-
[40]
Extrinsplat: Decoupling geometry and semantics for open-vocabulary understanding in 3d gaussian splatting,
J. Ding, X. Liu, Z. Pan, S. Long, and G. Li, “Extrinsplat: Decoupling geometry and semantics for open-vocabulary understanding in 3d gaussian splatting,” inProceedings of the IEEE/CVF Conference on Computer Vision and Pattern Recognition, 2026, pp. 31 019–31 028
2026
-
[41]
Desplat: Decomposed gaussian splatting for distractor- free rendering,
Y . Wang, M. Klasson, M. Turkulainen, S. Wang, J. Kannala, and A. Solin, “Desplat: Decomposed gaussian splatting for distractor- free rendering,” inProceedings of the Computer Vision and Pattern Recognition Conference, 2025, pp. 722–732
2025
-
[42]
Hybridgs: Decoupling transients and statics with 2d and 3d gaussian splatting,
J. Lin, J. Gu, L. Fan, B. Wu, Y . Lou, R. Chen, L. Liu, and J. Ye, “Hybridgs: Decoupling transients and statics with 2d and 3d gaussian splatting,” inProceedings of the Computer Vision and Pattern Recognition Conference, 2025, pp. 788–797
2025
-
[43]
Grounding image matching in 3d with mast3r,
V . Leroy, Y . Cabon, and J. Revaud, “Grounding image matching in 3d with mast3r,” inEuropean conference on computer vision. Springer, 2024, pp. 71–91
2024
-
[44]
A benchmark for the evaluation of rgb-d slam systems,
J. Sturm, N. Engelhard, F. Endres, W. Burgard, and D. Cremers, “A benchmark for the evaluation of rgb-d slam systems,” in2012 IEEE/RSJ international conference on intelligent robots and systems. IEEE, 2012, pp. 573–580
2012
-
[45]
Image quality assessment: from error visibility to structural similarity,
Z. Wang, A. C. Bovik, H. R. Sheikh, and E. P. Simoncelli, “Image quality assessment: from error visibility to structural similarity,”IEEE transactions on image processing, vol. 13, no. 4, pp. 600–612, 2004
2004
-
[46]
The unreasonable effectiveness of deep features as a perceptual metric,
R. Zhang, P. Isola, A. A. Efros, E. Shechtman, and O. Wang, “The unreasonable effectiveness of deep features as a perceptual metric,” in Proceedings of the IEEE conference on computer vision and pattern recognition, 2018, pp. 586–595
2018
Reviewed August 14, 2026 · model on record in the stance chip above.
Discussion (0). Continue with ORCID to comment.