pith. sign in

arxiv: 1201.5386 · v1 · pith:2EE2NFIVnew · submitted 2012-01-25 · ❄️ cond-mat.supr-con · physics.acc-ph

Low temperature laser scanning microscopy of a superconducting radio-frequency cavity

classification ❄️ cond-mat.supr-con physics.acc-ph
keywords surfacelaserresistanceapparatuscavitymicroscopyradio-frequencyresolution
0
0 comments X
read the original abstract

An apparatus was developed to obtain, for the first time, 2D maps of the surface resistance of the inner surface of an operating superconducting radio-frequency niobium cavity by a low-temperature laser scanning microscopy technique. This allows identifying non-uniformities of the surface resistance with a spatial resolution of about one order of magnitude better than with earlier methods and surface resistance resolution of ~ 1 micro-Ohm at 3.3 GHz. A signal-to-noise ratio of about 10 dB was obtained with 240 mW laser power and 1 Hz modulation frequency. The various components of the apparatus, the experimental procedure and results are discussed in detail in this contribution.

This paper has not been read by Pith yet.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.