Pith. sign in

REVIEW 1 cited by

The CMS HGCAL detector for HL-LHC upgrade

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 1708.08234 v1 pith:2WDEI5P3 submitted 2017-08-28 physics.ins-det hep-ex

classification physics.ins-dethep-ex
keywords willhcalhl-lhcpileupcalorimetryecalespeciallyevent
verification ladder T0 review T1 audit T2 compute T3 formal

Signed reviews

No signed human review yet.

0 comments
abstract

The High Luminosity LHC (HL-LHC) will integrate 10 times more luminosity than the LHC, posing significant challenges for radiation tolerance and event pileup on detectors, especially for forward calorimetry, and hallmarks the issue for future colliders. As part of its HL-LHC upgrade program, the CMS collaboration is designing a High Granularity Calorimeter to replace the existing endcap calorimeters. It features unprecedented transverse and longitudinal segmentation for both electromagnetic (ECAL) and hadronic (HCAL) compartments. This will facilitate particle-flow calorimetry, where the fine structure of showers can be measured and used to enhance pileup rejection and particle identification, whilst still achieving good energy resolution. The ECAL and a large fraction of HCAL will be based on hexagonal silicon sensors of 0.5-1cm$^{2}$ cell size, with the remainder of the HCAL based on highly-segmented scintillators with SiPM readout. The intrinsic high-precision timing capabilities of the silicon sensors will add an extra dimension to event reconstruction, especially in terms of pileup rejection. An overview of the HGCAL project is presented, covering motivation, engineering design, readout and trigger concepts, and performance (simulated and from beam tests).

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. Photon Reconstruction Performance at the CEPC baseline detector

    physics.ins-det 2019-08 conditional novelty 5.0 of 10

    Using full simulation, the CEPC baseline detector reconstructs isolated photons with over 99% efficiency and purity above 1 GeV, reaching a 2.2% H to gamma gamma mass resolution after a geometry-based correction.

Pith tools