Pith. sign in

REVIEW 1 cited by

A Search for Intrinsic HI 21 cm and OH 18 cm Absorption Toward Compact Radio Sources

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 1909.12422 v1 pith:42LPH27L submitted 2019-09-26 astro-ph.GA

A Search for Intrinsic HI 21 cm and OH 18 cm Absorption Toward Compact Radio Sources

classification astro-ph.GA
keywords absorptionintrinsicradiosourcesluminositycompacthighredshift
verification ladder T0 review T1 audit T2 compute T3 formal T4 reserved
0 comments
read the original abstract

We present the results of a large search for intrinsic HI 21 cm and OH 18 cm absorption in 145 compact radio sources in the redshift range 0.02< z <3.8 with the Green Bank Telescope. We re-detect HI 21 cm absorption toward six known absorption systems but detect no new HI or OH absorption in 102 interference-free sources. 79 sources have not previously been observed for HI 21 cm absorption. We recover a mean optical depth limit of $\tau_{3\sigma}<0.023$ for all the non-detections in the survey. Our results do not support the high intrinsic absorption rates found by previous studies in compact radio sources at low redshift. Our results do, however, support the hypothesis proposed by Curran et al. (2008) that high ultraviolet (UV) luminosity active galactic nuclei (AGN) do not show intrinsic HI 21 cm absorption, confirming a threshold of $L_{\rm UV} = 10^{23}$ W Hz$^{-1}$, above which our intrinsic absorption fraction is zero (54 sources). The exact nature of the UV luminosity effect on HI absorption systems remains ambiguous. We additionally find no statistical correlation between the 1.4 GHz radio luminosity or the source size and the 21~cm absorption detection rate. We attribute the lack of intrinsic absorption in our survey to the UV luminosity effect caused by an optical selection bias and a decreased column density sensitivity with increasing redshift due to lower radio continuum flux densities, high radio frequency interference, and higher telescope system temperatures at low frequencies.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score.

  1. The FAST HI 21-cm Absorption Blind Survey. III. OH Absorption Search in the 21-cm Absorber Sample and Continued HI Absorption Search

    astro-ph.GA 2026-07 accept novelty 5.0

    A blind FAST survey of 41 HI absorbers re-detected the known OH absorber PKS 1413+135, found no new OH, and set [OH]/[HI] upper limits near 1e-8.