Pith. sign in

REVIEW

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2205.00123 v5 pith:4AORCT25 submitted 2022-04-30 physics.optics eess.IV

Deep-learning-augmented Computational Miniature Mesoscope

classification physics.optics eess.IV
keywords imagingtimesacrosscomputationalminiatureresolutionaccurateaxial
verification ladder T0 review T1 audit T2 compute T3 formal T4 reserved
0 comments
read the original abstract

Fluorescence microscopy is essential to study biological structures and dynamics. However, existing systems suffer from a tradeoff between field-of-view (FOV), resolution, and complexity, and thus cannot fulfill the emerging need of miniaturized platforms providing micron-scale resolution across centimeter-scale FOVs. To overcome this challenge, we developed Computational Miniature Mesoscope (CM$^2$) that exploits a computational imaging strategy to enable single-shot 3D high-resolution imaging across a wide FOV in a miniaturized platform. Here, we present CM$^2$ V2 that significantly advances both the hardware and computation. We complement the 3$\times$3 microlens array with a new hybrid emission filter that improves the imaging contrast by 5$\times$, and design a 3D-printed freeform collimator for the LED illuminator that improves the excitation efficiency by 3$\times$. To enable high-resolution reconstruction across the large imaging volume, we develop an accurate and efficient 3D linear shift-variant (LSV) model that characterizes the spatially varying aberrations. We then train a multi-module deep learning model, CM$^2$Net, using only the 3D-LSV simulator. We show that CM$^2$Net generalizes well to experiments and achieves accurate 3D reconstruction across a $\sim$7-mm FOV and 800-$\mu$m depth, and provides $\sim$6-$\mu$m lateral and $\sim$25-$\mu$m axial resolution. This provides $\sim$8$\times$ better axial localization and $\sim$1400$\times$ faster speed as compared to the previous model-based algorithm. We anticipate this simple and low-cost computational miniature imaging system will be impactful to many large-scale 3D fluorescence imaging applications.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.