Pith. sign in

REVIEW 1 cited by

Towards Motion Compensation in Autonomous Robotic Subretinal Injections

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2411.18521 v2 pith:4RCQWJB7 submitted 2024-11-27 cs.RO

classification cs.RO
keywords injectionssubretinalmotionroboticamplitudecellscompensationmotions
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
abstract

Exudative (wet) age-related macular degeneration (AMD) is a leading cause of vision loss in older adults, typically treated with intravitreal injections. Emerging therapies, such as subretinal injections of stem cells, gene therapy, small molecules and RPE cells require precise delivery to avoid damaging delicate retinal structures. Robotic systems can potentially offer the necessary precision for these procedures. This paper presents a novel approach for motion compensation in robotic subretinal injections, utilizing real time Optical Coherence Tomography (OCT). The proposed method leverages B$^5$-scans, a rapid acquisition of small-volume OCT data, for dynamic tracking of retinal motion along the Z-axis, compensating for physiological movements such as breathing and heartbeat. Validation experiments on ex vivo porcine eyes revealed challenges in maintaining a consistent tool-to-retina distance, with deviations of up to 200 $\mu m$ for 100 $\mu m$ amplitude motions and over 80 $\mu m$ for 25 $\mu m$ amplitude motions over one minute. Subretinal injections faced additional difficulties, with phase shifts causing the needle to move off-target and inject into the vitreous. These results highlight the need for improved motion prediction and horizontal stability to enhance the accuracy and safety of robotic subretinal procedures.

Discussion (0). Sign in to comment.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. RCM-ACT: Imitation Learning with Dynamic RCM Calibration for Autonomous Intraocular Foreign Body Removal

    cs.RO 2025-08 conditional novelty 6.0 of 10

    An imitation-learning robot with dynamic coordinate calibration can grasp and place a 1.22 mm ring in an eye model with 0.686 mm average error, but full-task success was only 5/10 in the reported table.

Pith tools