Pith. sign in

REVIEW

Validation and Generalizability of Self-Supervised Image Reconstruction Methods for Undersampled MRI

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2201.12535 v3 pith:556OPU5U submitted 2022-01-29 eess.IV cs.AIphysics.med-ph

classification eess.IVcs.AIphysics.med-ph
keywords generalizabilitymethodsreconstructionself-superviseddataimagereconstructionsmetrics
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
read the original abstract

Deep learning methods have become the state of the art for undersampled MR reconstruction. Particularly for cases where it is infeasible or impossible for ground truth, fully sampled data to be acquired, self-supervised machine learning methods for reconstruction are becoming increasingly used. However potential issues in the validation of such methods, as well as their generalizability, remain underexplored. In this paper, we investigate important aspects of the validation of self-supervised algorithms for reconstruction of undersampled MR images: quantitative evaluation of prospective reconstructions, potential differences between prospective and retrospective reconstructions, suitability of commonly used quantitative metrics, and generalizability. Two self-supervised algorithms based on self-supervised denoising and the deep image prior were investigated. These methods are compared to a least squares fitting and a compressed sensing reconstruction using in-vivo and phantom data. Their generalizability was tested with prospectively under-sampled data from experimental conditions different to the training. We show that prospective reconstructions can exhibit significant distortion relative to retrospective reconstructions/ground truth. Furthermore, pixel-wise quantitative metrics may not capture differences in perceptual quality accurately, in contrast to a perceptual metric. In addition, all methods showed potential for generalization; however, generalizability is more affected by changes in anatomy/contrast than other changes. We further showed that no-reference image metrics correspond well with human rating of image quality for studying generalizability. Finally, we showed that a well-tuned compressed sensing reconstruction and learned denoising perform similarly on all data.

Discussion (0). Continue with ORCID to comment.

Pith tools