Long term characterization of voltage references

classification ⚛️ physics.ins-det astro-ph.IM
keywords referencescharacterizationvoltagedevicespreviousstudiesweread587uq
0
0 comments X
read the original abstract

We report here the characterization (temperature coefficients and noise level) of selected voltage references in the frequency range from 10^(-5) to 10 Hz. The goal of this work is to update previous studies, with a characterization at lower frequencies, and find voltage references that may be suitable for the space-based interferometry mission eLISA. The requirements of relative output stability of 1 ppm/$\sqrt{\text{Hz}}$ down to 0.1 mHz were not met by any of the tested devices, but 4 references approaches the objective : the AD587UQ, the MAX6126AASA50, the LT1021-BCN8-5 and the LT6655BHM. While the first three were already identified as potential devices in previous studies, the later is a new promising candidate using a different technology (bandgap).