Pith. sign in

REVIEW 1 cited by

Anisotropic twicing for single particle reconstruction using autocorrelation analysis

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 1704.07969 v1 pith:5ZKFWX76 submitted 2017-04-26 cs.CV q-bio.BMstat.APstat.ME

classification cs.CVq-bio.BMstat.APstat.ME
keywords twicingmagnitudesstructureanalysisanisotropicautocorrelationmolecularparticle
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
read the original abstract

The missing phase problem in X-ray crystallography is commonly solved using the technique of molecular replacement, which borrows phases from a previously solved homologous structure, and appends them to the measured Fourier magnitudes of the diffraction patterns of the unknown structure. More recently, molecular replacement has been proposed for solving the missing orthogonal matrices problem arising in Kam's autocorrelation analysis for single particle reconstruction using X-ray free electron lasers and cryo-EM. In classical molecular replacement, it is common to estimate the magnitudes of the unknown structure as twice the measured magnitudes minus the magnitudes of the homologous structure, a procedure known as `twicing'. Mathematically, this is equivalent to finding an unbiased estimator for a complex-valued scalar. We generalize this scheme for the case of estimating real or complex valued matrices arising in single particle autocorrelation analysis. We name this approach "Anisotropic Twicing" because unlike the scalar case, the unbiased estimator is not obtained by a simple magnitude isotropic correction. We compare the performance of the least squares, twicing and anisotropic twicing estimators on synthetic and experimental datasets. We demonstrate 3D homology modeling in cryo-EM directly from experimental data without iterative refinement or class averaging, for the first time.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. Two Datasets Are Better Than One: Method of Double Moments for 3-D Reconstruction in Cryo-EM

    cs.CV 2025-11 conditional novelty 7.0 of 10

    A bandlimited 3-D structure is uniquely determined, up to rotation and reflection, by one uniform-dataset second moment plus a second non-uniform dataset's second moment.

Pith tools