Pith. sign in

REVIEW

Gas Gains Over 10⁴ and Optimisation using ⁵⁵Fe X-rays in Low Pressure SF₆ with a Novel Multi-Mesh ThGEM for Directional Dark Matter Searches

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2311.10556 v1 pith:6RQCM4P4 submitted 2023-11-17 physics.ins-det

Gas Gains Over 10⁴ and Optimisation using ⁵⁵Fe X-rays in Low Pressure SF₆ with a Novel Multi-Mesh ThGEM for Directional Dark Matter Searches

classification physics.ins-det
keywords gainsdevicedirectionalelectrongainorderpreviouslydark
verification ladder T0 review T1 audit T2 compute T3 formal T4 reserved
0 comments
read the original abstract

The Negative Ion Drift (NID) gas SF$_6$ has favourable properties for track reconstruction in directional Dark Matter (DM) searches utilising low pressure gaseous Time Projection Chambers (TPCs). However, the electronegative nature of the gas means that it is more difficult to achieve significant gas gains with regular Thick Gaseous Electron Multipliers (ThGEMs). Typically, the maximum attainable gas gain in SF$_6$ and other Negative Ion (NI) gas mixtures, previously achieved with an $^{55}$Fe X-ray source or electron beam, is on the order of $10^3$; whereas electron drift gases like CF$_4$ and similar mixtures are readily capable of reaching gas gains on the order of $10^4$ or greater. In this paper, a novel two stage Multi-Mesh ThGEM (MMThGEM) structure is presented. The MMThGEM was used to amplify charge liberated by an $^{55}$Fe X-ray source in 40 Torr of SF$_6$. By expanding on previously demonstrated results, the device was pushed to its sparking limit and stable gas gains up to $\sim$50000 were observed. The device was further optimised by varying the field strengths of both the collection and transfer regions in isolation. Following this optimisation procedure, the device was able to produce a maximum stable gas gain of $\sim$90000. These results demonstrate an order of magnitude improvement in gain with the NID gas over previously reported values and ultimately benefits the sensitivity of a NITPC to low energy recoils in the context of a directional DM search.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.