Pith. sign in

REVIEW 1 cited by

The future of X-ray polarimetry towards the 3-Dimensional photoelectron track reconstruction

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2309.17206 v1 pith:6X5L7UEW submitted 2023-09-29 astro-ph.IM

classification astro-ph.IM
keywords trackx-raypolarimetryphotoelectronreconstructionthree-dimensionalhighimprovement
verification ladder T0 review T1 audit T2 compute T3 formal

Signed reviews

No signed human review yet.

0 comments
abstract

The development of the first X-ray polarimeter, based on the photoelectric effect 20 years ago and implemented thanks to advances in gas amplification structures and readout techniques, had a significant impact in opening a new window for X-ray polarimetry. This system measures the X-ray polarization by reconstructing the initial direction of the photoelectron, emitted by the interaction of an incident photon with an atomic electron, in a gas mixture from an ionization track collected on a two-dimensional plane. However, actual X-ray polarimeters, are still requiring relatively long exposure time and cannot coupled with high effective area mirrors or concentrators. In this context, the high yield polarimetry experiment in X-rays (Hype-X) project is currently underway, aiming to improve the sensitivity of the next generation X-ray polarimetry detectors taking advantage of the recent advancements in imaging techniques for high-resolution time projection chambers. In particular, we are evaluating the use of TIMEPIX3 to be applied for the read-out of a gas detector, which will allow us to obtain a three-dimensional image of the photoelectron track. To evaluate the improvement achievable by using a 3D track reconstruction, in this paper, we have reproduced a three-dimensional photoelectron track from a 'Geant4' Monte Carlo simulation and examined the sensitivity of X-ray polarimetry using a new three-dimensional track reconstruction algorithm. We report the improvement of the modulation factor with three-dimensional track reconstruction as $\sim5\%$ (relative) in the 2-8 keV range and $\sim17\%$ (relative) in the 2-4 keV range compared to the current two-dimensional polarimetry system. This is equivalent to add a further telescope to the three-telescope systems now employed in space on board the IXPE mission.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. The hitchhiker's guide to the IXPE data analysis

    astro-ph.HE 2026-04 conditional novelty 3.0 of 10

    A user-oriented guide that collects best practices, data formats, and analysis strategies for extracting polarimetric information from IXPE observations.

Pith tools