Pith. sign in

REVIEW 1 cited by

Open-Vocabulary Calibration for Fine-tuned CLIP

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2402.04655 v4 pith:7EDGGDV7 submitted 2024-02-07 cs.LG

classification cs.LG
keywords calibrationmethodsproblemlearningopen-vocabularypromptvlmsbeen
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
read the original abstract

Vision-language models (VLMs) have emerged as formidable tools, showing their strong capability in handling various open-vocabulary tasks in image recognition, text-driven visual content generation, and visual chatbots, to name a few. In recent years, considerable efforts and resources have been devoted to adaptation methods for improving downstream performance of VLMs, particularly on parameter-efficient fine-tuning methods like prompt learning. However, a crucial aspect that has been largely overlooked is the confidence calibration problem in fine-tuned VLMs, which could greatly reduce reliability when deploying such models in the real world. This paper bridges the gap by systematically investigating the confidence calibration problem in the context of prompt learning and reveals that existing calibration methods are insufficient to address the problem, especially in the open-vocabulary setting. To solve the problem, we present a simple and effective approach called Distance-Aware Calibration (DAC), which is based on scaling the temperature using as guidance the distance between predicted text labels and base classes. The experiments with 7 distinct prompt learning methods applied across 11 diverse downstream datasets demonstrate the effectiveness of DAC, which achieves high efficacy without sacrificing the inference speed. Our code is available at https://github.com/ml-stat-Sustech/CLIP_Calibration.

Discussion (0). Sign in to comment.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. Prompting without Panic: Attribute-aware, Zero-shot, Test-Time Calibration

    cs.CV 2025-06 conditional novelty 6.0 of 10

    Attribute-aware test-time prompt tuning with intra/inter-class text dispersion losses reduces average ECE from 11.7 to 4.11 across 11 fine-grained CLIP benchmarks.

Pith tools