REVIEW 4 major objections 4 minor 52 references
A Low-Power Wearable Respiratory Sensor for Non-Invasive Stress Monitoring
T0 review · 4 major / 4 minor · reviewed 2026-08-08 · deepseek-v4-flash
Pith's one-line read A low-power abdominal belt sensor can separate stress from rest by breathing alone, the paper claims.
desk verdict A solid engineering report on a low-cost FSR respiratory belt, with a stress-classification experiment whose headline accuracy is inflated by feature-selection leakage and segment-level splits. read the letter →
The pith
A machine-rendered reading of the paper's core claim, the machinery that carries it, and where it could break.
The reading
What carries the argument
The load-bearing object is the force-sensitive resistor (FSR) read by a voltage divider: $V_{out} = V_{dd} R_L/(R_{FSR}+R_L)$, so inhalation increases pressure, lowers $R_{FSR}$, and raises the ADC voltage without an amplifier. A flexible holder with a central button transfers abdominal expansion to the sensor, and an nRF52832-based BLE board digitizes and transmits the waveform. The stress-decoding claim is carried by 28 time-domain features reduced to six by Fisher's criterion, which ranks each feature by the ratio of between-class to within-class variance, and these features are fed to standard classifiers under six-fold cross-validation.
What would settle it
Run leave-one-participant-out cross-validation, repeating Fisher feature selection inside each training fold; if accuracy on held-out participants falls to chance, the reported 88.0% is an artifact of segment overlap rather than a general respiratory marker of stress.
Extended reading notes
Core claim
The paper's central claim is that a piezoresistive readout with no analog amplification, combined with a mechanical holder that concentrates abdominal expansion onto the FSR, produces a respiratory waveform large enough to support downstream classification. The paper reports that in stationary postures and light walking the filtered waveform preserves recurring peak-valley structure, and that six interpretable time-domain features—chief among them variance of expiratory slope—distinguish rest from stress-induction phases with 88.0% test accuracy in the pilot dataset. This result is presented as preliminary evidence for the feasibility of respiration-only stress decoding, not as a demonstrated generalizable biomarker.
Load-bearing premise
The load-bearing premise is that the 60 segments from 12 participants can be treated as independent samples for training and testing, even though features are selected on the full dataset and segments from the same participant may appear in both training and test folds; if that premise fails, the 88.0% test accuracy does not generalize beyond this dataset.
Editorial extensions
If this is right
- The device can measure respiratory rate and intensity across sitting, lying, standing, and light walking with a single low-cost FSR channel.
- The passive readout and regulated 1.8 V supply keep power consumption low, since the FSR's high unloaded resistance reduces divider current during standby.
- Features such as variance of expiratory slope differentiate stress-induction phases from relaxation phases within the recorded protocol.
- The system supports real-time BLE streaming at about 7.31 kbps, enough for continuous respiratory monitoring outside the lab.
- The paper concludes that combining respiration with electrodermal activity, ECG/HRV, and motion sensing is the more promising route to robust stress inference, positioning this single-channel result as a building block.
Reading between the lines
- Because participants spoke during the arithmetic and Stroop blocks, part of the reported discrimination may reflect speech-driven breathing changes rather than stress per se; a silent stress task would separate these factors.
- If leave-one-participant-out validation holds, a single FSR channel could serve as a low-cost, low-power screening signal for longitudinal stress studies without chest straps or multiple sensors.
- The same voltage-divider readout could be repurposed for other slow mechanical signals such as posture shifts or gait cadence with only a change of holder geometry.
- A placement-sweep study could estimate how much of the 88.0% accuracy transfers across sensor positions, since the paper notes that attachment pressure and placement set the operating point and can produce baseline shifts.
Editorial analysis
A structured set of objections, weighed in public.
Referee Report
Summary. The paper presents a compact, low-power wearable respiratory sensor based on a force-sensitive resistor (FSR) in an abdominal belt with a custom Bluetooth Low Energy acquisition board and no analog amplification. The authors report qualitative waveform validation across breathing modes and body positions (sitting, lying, standing, walking) and a preliminary stress-induction experiment with 12 participants, 60 labeled segments, 28 time-domain features, Fisher-based feature selection, and six-fold cross-validation of five classifiers, with a reported best test accuracy of 88.0%.
Significance. If the hardware claims are correct, the device is a low-cost, low-complexity respiratory channel with a plausible path to continuous monitoring, and the paper gives a reasonably complete account of the mechanical and electronic design. The stress-classification result, however, is the central evidence for the affective-computing claim, and that result is currently undermined by a circular feature-selection evaluation and by the confounding of stress phases with speaking. The paper itself acknowledges several of these limitations (Section 5), which is a strength, but the abstract and introduction do not carry the necessary caveats. The hardware validation is qualitative and would benefit from quantitative comparison to a reference method.
major comments (4)
- [§3.5.5–3.5.6, Table 2] The six features are selected using Fisher's criterion on all 60 labeled segments before the six-fold cross-validation is performed. This means the test folds have already influenced feature selection, so the reported 88.0% test accuracy (and the 82.4% average) is an optimistic, leakage-contaminated estimate. The abstract's claim that the features 'distinguish stress-induced phases from relaxation phases' is not supported by this evaluation. A nested cross-validation procedure, or feature selection performed only within each training fold, is required.
- [§3.5.4, §3.5.6] The six-fold cross-validation splits the 60 segments, not the 12 participants. With five segments per participant, random folds will almost certainly place segments from the same participant in both training and test sets, allowing the classifier to exploit participant-specific baseline, belt tension, or placement effects rather than the rest/stress contrast. The reported accuracy therefore cannot be interpreted as subject-independent performance. Grouped or participant-independent folds should be used, and per-participant variability should be reported.
- [§4.2.1, §3.5.3] As the paper itself notes in Section 4.2.1, participants speak during the mental-arithmetic and SCWT phases but not during rest phases, and speech directly alters respiratory timing and waveform shape. Consequently, even a methodologically clean binary classifier would likely discriminate task phases (speaking vs. silent) rather than stress per se. The abstract's phrasing 'distinguish stress-induced phases from relaxation phases' is therefore an overstatement. A speech-matched control condition, or an explicit analysis of speech confounds, is needed before the result can be attributed to stress induction.
- [§4.1, §3.4.3, Appendix F] The hardware validation is qualitative: waveform inspection for a single subject per posture, with no comparison to a reference respiratory measurement (e.g., respiratory inductance plethysmography or a spirometer) and no quantitative breath-by-breath accuracy metrics. Appendix F additionally shows conditions where motion and placement dominate the signal. The abstract's claim that the platform 'enables real-time respiratory monitoring across diverse daily-life scenarios' is broader than the evidence supports. Quantitative agreement statistics across subjects, sessions, and sensor placements would be needed to substantiate that claim.
minor comments (4)
- [Abstract] The abstract reports the 88.0% test accuracy without noting that it comes from a segment-level evaluation with known limitations; even the Introduction qualifies this as 'under the original segment-level evaluation.' The abstract should carry the same caveat or refer the reader to the limitation.
- [Figure 7] The four panels are not individually labeled with the corresponding posture (sitting, lying, standing, walking), making it hard to map the qualitative claims in the text to the displayed traces.
- [Table 2] The abbreviations 'spec.' and 'sens.' are not defined in the table caption; adding 'specificity' and 'sensitivity' would improve readability.
- [Section 4.2.2] The cold pressor test description reports a '20%' amplitude increase but does not state over how many subjects or sessions this was measured; please clarify the basis of this number.
Circularity Check
Feature selection on all 60 labeled segments before six-fold cross-validation makes the headline 88.0% 'test accuracy' a leakage-prone, partially in-sample evaluation rather than an independent prediction.
-
fitted input called prediction
[Section 3.5.5 (Feature Extraction), Section 3.5.6 (Classification Setup), Table 2, and the abstract's '88.0% test accuracy' claim]
"For model training, six features were selected using Fisher’s criterion [14] because they provided the strongest separation between stress and rest classes... The models were evaluated using six-fold cross-validation over the 60 labeled segments. In each fold, 50 samples were used for training and 10 samples were used for testing."
The Fisher feature selector is applied to all 60 labeled segments before any train/test split, so the six features scored in each 'test' fold were chosen with knowledge of that fold's labels. The reported 88.0% test accuracy is therefore not an out-of-sample estimate of a pre-selected feature set; it evaluates a feature set fitted on the full data. Because folds are drawn from 12 participants' five segments without participant separation, same-participant segments can appear in both training and test, further correlating the estimate. The paper itself concedes the limitation in Section 5, calling 'the original segment-level evaluation is limited' and requesting 'held-out-participant evaluation'.
full rationale
The sensing and hardware derivation is self-contained: Eq. (1) is a passive voltage divider, the FSR resistance-pressure mapping is from an external datasheet, and the posture/motion results are direct empirical checks independent of the classification model. The circularity is confined to the stress-decoding claim. In Section 3.5.5, six features are selected by Fisher's criterion over all 60 segments; Section 3.5.6 then cross-validates classifiers on the same 60 segments. Because feature selection uses test-fold labels before any split, the abstract's statement that the 88.0% accuracy is 'indicating that the extracted respiratory features distinguish stress-induced phases from relaxation phases in this dataset' is supported by an evaluation loop: the feature set already incorporated all labels. Section 5 explicitly flags this ('the original segment-level evaluation is limited') and asks for held-out-participant evaluation, and Section 4.2.1 acknowledges that participants speak during stress tasks, so phase differences also reflect task behavior. The introduction's self-citations ([20], [21], [35]) are not load-bearing for the sensor or the classification result. Overall, the hardware claim remains independent, but the headline classification result is partially circular due to full-data feature selection, justifying a score of 6.
Assumptions & free parameters
free parameters (7)
- Fisher-selected feature subset =
variance of valley intervals; max peak-to-valley interval; variance of inspiratory time; mean expiratory volume…
- Load resistor RL =
10 kOhm
- FIR low-pass cutoff =
2 Hz
- Neural network hidden units =
20
- ADC sampling rate and oversampling factor =
428 Hz, factor 8
- BLE packet interval =
17.5 ms
- Phase durations =
Rest 4 min; tasks 2 to 3 min; recovery 3 min
assumptions (6)
- domain assumption FSR resistance decreases monotonically with applied pressure (manufacturer datasheet).
- domain assumption Abdominal expansion during inhalation increases pressure on the FSR through the holder.
- domain assumption The 2 Hz low-pass filter preserves respiratory frequencies while removing motion noise.
- domain assumption Stroop and mental arithmetic tasks induce stress as established in prior literature.
- domain assumption The 60 segments are independent samples for cross-validation.
- domain assumption Peak and valley detection algorithm correctly identifies breaths in all phases.
Cite this review
Pith. "Pith review of A Low-Power Wearable Respiratory Sensor for Non-Invasive Stress Monitoring." pith.science (2026). https://pith.science/paper/7O2AOG6H
@misc{pith2026260805697,
author = {Pith},
title = {Pith review of: A Low-Power Wearable Respiratory Sensor for Non-Invasive Stress Monitoring},
year = {2026},
howpublished = {\url{https://pith.science/paper/7O2AOG6H}},
note = {Machine review of arXiv:2608.05697}
}
read the original abstract
Respiration provides a continuously available window into physiological state and behavior. However, monitoring it outside controlled settings remains challenging because a wearable system must capture small body deformations while remaining comfortable, low power, and robust to changes in posture and motion. We present a compact non-invasive respiratory sensing system based on a force-sensitive resistor (FSR) embedded in an abdominal belt and integrated with a custom Bluetooth Low Energy acquisition board. The system combines a simple piezoresistive readout with a mechanical holder designed to transfer abdominal expansion to the sensor without analog amplification. We evaluate the complete sensing pipeline across multiple breathing patterns and body positions. In stationary settings, the recorded signals exhibit consistent amplitude changes and recurring peak-to-peak timing across breathing maneuvers; under light movement, these variations remain visible despite motion-induced baseline shifts. We further design a five-phase stress-induction protocol and collect respiratory recordings from 12 participants. Using interpretable time-domain features and standard classifiers, we examine whether the acquired signals distinguish relaxation from stress-induction phases. In this preliminary experiment, the best-performing model achieves 88.0% test accuracy, indicating that the extracted respiratory features distinguish stress-induced phases from relaxation phases in this dataset. Overall, our results show that the proposed platform enables real-time respiratory monitoring across diverse daily-life scenarios and captures respiratory changes that distinguish stress-induction from relaxation phases, supporting its potential for affective-computing applications.
Figures
Figures from the paper (8 more)
Reference graph
Works this paper leans on
-
[1]
F. Q. Al-Khalidi, R. Saatchi, D. Burke, H. Elphick, and S. Tan. Respiration rate monitoring methods: A review.Pediatric Pulmonology, 46(6):523–529, 2011. doi: 10.1002/ppul.21416
-
[2]
Frans A. Boiten. The effects of emotional behaviour on components of the respiratory cycle. Biological Psychology, 49(1–2):29–51, 1998. doi: 10.1016/S0301-0511(98)00025-8
-
[3]
Sirikarn Boonnithi and Siriwan Phongsuphap. Comparison of heart rate variability measures for mental stress detection.Computing in Cardiology, pages 85–88, 2011
work page 2011
-
[4]
Peter H. Charlton, Drew A. Birrenkott, Timothy Bonnici, Marco A. F. Pimentel, Alistair E. W. Johnson, Jordi Alastruey, Lionel Tarassenko, Peter J. Watkinson, Richard Beale, and David A. Clifton. Breathing rate estimation from the electrocardiogram and photoplethysmogram: A review.IEEE Reviews in Biomedical Engineering, 11:2–20, 2018. doi: 10.1109/RBME.201...
-
[5]
Ang Chen, Jianwei Zhang, Liangkai Zhao, Rachel Diane Rhoades, Dong-Yun Kim, Ning Wu, Jianming Liang, and Junseok Chae. Machine-learning enabled wireless wearable sensors to study individuality of respiratory behaviors.Biosensors and Bioelectronics, 173:112799, 2021. doi: 10.1016/j.bios.2020.112799
-
[6]
Youngjun Cho, Nadia Bianchi-Berthouze, and Simon J. Julier. Deepbreath: Deep learning of breathing patterns for automatic stress recognition using low-cost thermal imaging in uncon- strained settings.arXiv preprint arXiv:1708.06026, 2017. URL https://arxiv.org/abs/ 1708.06026
work page Pith review arXiv 2017
-
[7]
Using heart rate monitors to detect mental stress
Jongyoon Choi and Ricardo Gutierrez-Osuna. Using heart rate monitors to detect mental stress. InSixth International Workshop on Wearable and Implantable Body Sensor Networks, pages 219–223, 2009. doi: 10.1109/BSN.2009.13
-
[8]
Pham, Ronen Bar- Yoseph, Shlomit Radom-Aizik, Ramesh Jain, Dan M
Michael Chu, Thao Nguyen, Vaibhav Pandey, Yongxiao Zhou, Hoang N. Pham, Ronen Bar- Yoseph, Shlomit Radom-Aizik, Ramesh Jain, Dan M. Cooper, and Michelle Khine. Respiration rate and volume measurements using wearable strain sensors.npj Digital Medicine, 2:8, 2019. doi: 10.1038/s41746-019-0083-3
Show all 52 references
-
[9]
Computational psychometrics using psychophysiological measures for the assessment of acute mental stress.Sensors, 19(4):781,
Pietro Cipresso, Desirée Colombo, and Giuseppe Riva. Computational psychometrics using psychophysiological measures for the assessment of acute mental stress.Sensors, 19(4):781,
-
[10]
Shepley, Nicholas J
Carter Comeau, Bhawya, Partha Sarati Das, Brooke R. Shepley, Nicholas J. Lester, Syed Anees, Anthony R. Bain, Simon Rondeau-Gagné, and Mohammed Jalal Ahamed. AI-enabled wireless wearable breathing sensor for breathing pattern recognition.Scientific Reports, 16:21380, 2026. doi...
2026 doi
-
[11]
Conrad and P
B. Conrad and P. Schönle. Speech and respiration.Archiv für Psychiatrie und Nervenkrankheiten, 226(4):251–268, 1979. doi: 10.1007/BF00342238
1979 doi
-
[12]
Cretikos, Rinaldo Bellomo, Ken Hillman, Jack Chen, Simon Finfer, and Arthas Flabouris
Michelle A. Cretikos, Rinaldo Bellomo, Ken Hillman, Jack Chen, Simon Finfer, and Arthas Flabouris. Respiratory rate: the neglected vital sign.The Medical Journal of Australia, 188(11): 657–659, 2008
2008
-
[13]
J. F. Fieselmann, M. S. Hendryx, C. M. Helms, and D. S. Wakefield. Respiratory rate predicts cardiopulmonary arrest for internal medicine inpatients.Journal of General Internal Medicine, 8(7):354–360, 1993. doi: 10.1007/BF02600071
1993 doi
-
[14]
Ronald A. Fisher. The use of multiple measurements in taxonomic problems.Annals of Eugenics, 7(2):179–188, 1936. doi: 10.1111/j.1469-1809.1936.tb02137.x
1936
-
[15]
Folke, L
M. Folke, L. Cernerud, M. Ekström, and B. Hök. Critical review of non-invasive respiratory monitoring in medical care.Medical and Biological Engineering and Computing, 41(4): 377–383, 2003. doi: 10.1007/BF02348078. 15
2003 doi
-
[16]
Continuous stress detection using a wrist device: In laboratory and real life
Martin Gjoreski, Hristijan Gjoreski, Mitja Luštrek, and Matjaž Gams. Continuous stress detection using a wrist device: In laboratory and real life. InProceedings of the ACM In- ternational Joint Conference on Pervasive and Ubiquitous Computing: Adjunct, 2016. doi: 10.1145/2968...
2016
-
[17]
Mittelstadt, and Omer Van den Bergh
Mariel Grassmann, Elke Vlemincx, Andreas von Leupoldt, Justin M. Mittelstadt, and Omer Van den Bergh. Respiratory changes in response to cognitive load: A systematic review.Neural Plasticity, 2016:8146809, 2016. doi: 10.1155/2016/8146809
2016 doi
-
[18]
Healey and Rosalind W
Jennifer A. Healey and Rosalind W. Picard. Detecting stress during real-world driving tasks using physiological sensors.IEEE Transactions on Intelligent Transportation Systems, 6(2): 156–166, 2005. doi: 10.1109/TITS.2005.848368
2005
-
[19]
Breathing rhythms and emotions.Experimental Physiology, 93(9):1011–1021, 2008
Ikuo Homma and Yuri Masaoka. Breathing rhythms and emotions.Experimental Physiology, 93(9):1011–1021, 2008. doi: 10.1113/expphysiol.2008.042424
2008 arXiv
-
[20]
Shanechi
Mohammad Hosseini, Eray Erturk, Saba Hashemi, and Maryam M. Shanechi. Cross-subject modeling for widefield calcium imaging via atlas-aligned spatiotemporal tokenization. InForty- third International Conference on Machine Learning, 2026. URL https://openreview. net/forum?id=pZq2RMptsQ
2026
-
[21]
Dynamical modeling of behaviorally rele- vant spatiotemporal patterns in neural imaging data
Sayed Mohammad Hosseini and Maryam Shanechi. Dynamical modeling of behaviorally rele- vant spatiotemporal patterns in neural imaging data. InForty-second International Conference on Machine Learning, 2025. URLhttps://openreview.net/forum?id=k4KVhQd19x
2025
-
[22]
cStress: Towards a gold standard for continuous stress assessment in the mobile environment
Karen Hovsepian, Mustafa al’Absi, Emre Ertin, Thomas Kamarck, Motohiro Nakajima, and Santosh Kumar. cStress: Towards a gold standard for continuous stress assessment in the mobile environment. InProceedings of the ACM International Joint Conference on Pervasive and Ubiquitous ...
2015
-
[23]
Wearable sensors for respiration monitoring: A review.Sensors, 23(17):7518, 2023
Tauseef Hussain, Sana Ullah, Raúl Fernández-García, and Ignacio Gil. Wearable sensors for respiration monitoring: A review.Sensors, 23(17):7518, 2023. doi: 10.3390/s23177518
2023 doi
-
[24]
FSR 402 short force sensing resistor integration guide and eval- uation parts catalog, 2020
Interlink Electronics. FSR 402 short force sensing resistor integration guide and eval- uation parts catalog, 2020. URL https://cdn.sparkfun.com/assets/8/a/1/2/0/ 2010-10-26-DataSheet-FSR402-Layout2.pdf. Datasheet and integration guide
2020
-
[25]
2450AT18B100E 2.4 ghz chip antenna datasheet, 2018
Johanson Technology. 2450AT18B100E 2.4 ghz chip antenna datasheet, 2018. URL https: //www.johansontechnology.com/docs/1187/2450AT18B100_X8XXogU.pdf. Antenna datasheet
2018
-
[26]
Karthikeyan, M
P. Karthikeyan, M. Murugappan, and Sazali Yaacob. Multiple physiological signal-based human stress identification using non-linear classifiers.Elektronika ir Elektrotechnika, 19(7):80–85,
-
[27]
An accurate respiratory rate estimation algorithm for a rubber fiber respiratory sensor.Journal of Industrial Textiles, 2024
Ji-seon Kim and Jooyong Kim. An accurate respiratory rate estimation algorithm for a rubber fiber respiratory sensor.Journal of Industrial Textiles, 2024. doi: 10.1177/15280837241248181
2024 doi
-
[28]
The cold pressor test and autonomic function: A review and integration
William Lovallo. The cold pressor test and autonomic function: A review and integration. Psychophysiology, 12(3):268–282, 1975. doi: 10.1111/j.1469-8986.1975.tb01289.x
1975
-
[29]
Mental stress detection using bioradar respiratory signals.Biomedical Signal Processing and Control, 43:244–249, 2018
José Raúl Machado Fernández and Lesya Anishchenko. Mental stress detection using bioradar respiratory signals.Biomedical Signal Processing and Control, 43:244–249, 2018. doi: 10.1016/j.bspc.2018.03.006
2018 doi
-
[30]
Contact-based methods for measuring respiratory rate.Sensors, 19(4):908,
Carlo Massaroni, Andrea Nicolò, Daniele Lo Presti, Massimo Sacchetti, Sergio Silvestri, and Emiliano Schena. Contact-based methods for measuring respiratory rate.Sensors, 19(4):908,
-
[31]
Kristin McClure, Brett Erdreich, Jason H. T. Bates, Ryan S. McGinnis, Axel Masquelin, and Safwan Wshah. Classification and detection of breathing patterns with wearable sensors and deep learning.Sensors, 20(22):6481, 2020. doi: 10.3390/s20226481. 16
2020 doi
-
[32]
The importance of respiratory rate monitoring: From healthcare to sport and exercise.Sensors, 20(21):6396, 2020
Andrea Nicolò, Carlo Massaroni, Emiliano Schena, and Massimo Sacchetti. The importance of respiratory rate monitoring: From healthcare to sport and exercise.Sensors, 20(21):6396, 2020. doi: 10.3390/s20216396
2020 doi
-
[33]
URLhttps://www.mdpi.com/1424-8220/19/4/908
-
[34]
Salai, I
M. Salai, I. Vassanyi, and I. Kosa. Stress detection using low cost heart rate sensors.Journal of Healthcare Engineering, 2016:5136705, 2016. doi: 10.1155/2016/5136705
2016 doi
-
[35]
Sani, Mohammad Hosseini, Trisha Jha, and Maryam M
Omid G. Sani, Mohammad Hosseini, Trisha Jha, and Maryam M. Shanechi. Preferential dynamic modeling with forward–backward smoothing, 2026. URL https://openreview. net/forum?id=2CJBngOZh5
2026
-
[36]
nRF52832 product specification, 2020
Nordic Semiconductor. nRF52832 product specification, 2020. URL https://docs. nordicsemi.com/r/bundle/ps_nrf52832. Official nRF52832 Product Specification
2020
-
[37]
Introducing WESAD, a multimodal dataset for wearable stress and affect detection
Philip Schmidt, Attila Reiss, Robert Dürichen, Claus Marberger, and Kristof Van Laerhoven. Introducing WESAD, a multimodal dataset for wearable stress and affect detection. InPro- ceedings of the 20th ACM International Conference on Multimodal Interaction, 2018. doi: 10.1145/3...
2018
-
[38]
Sriramprakash, V
S. Sriramprakash, V . D. Prasanna, and O. V . Ramana Murthy. Stress detection in working people.Procedia Computer Science, 115:359–366, 2017
2017
-
[39]
The stroop color and word test.Frontiers in Psychology, 8: 557, 2017
Federica Scarpina and Sofia Tagini. The stroop color and word test.Frontiers in Psychology, 8: 557, 2017. doi: 10.3389/fpsyg.2017.00557
2017
-
[40]
Machine learning framework for the detection of mental stress at multiple levels.IEEE Access, 5:13545–13556, 2017
Ahmad Rauf Subhani, Wajid Mumtaz, Mohamad Naufal Mohamad Saad, Nidal Kamel, and Aamir Saeed Malik. Machine learning framework for the detection of mental stress at multiple levels.IEEE Access, 5:13545–13556, 2017
2017
-
[41]
Activity-aware mental stress detection using physiological sensors
Feng-Tso Sun, Chris Kuo, Heng-Tze Cheng, Senaka Buthpitiya, Patrick Collins, and Martin Griss. Activity-aware mental stress detection using physiological sensors. InInternational Conference on Mobile Computing, Applications, and Services, pages 211–230. Springer, 2010
2010
-
[42]
Ridley Stroop
J. Ridley Stroop. Studies of interference in serial verbal reactions.Journal of Experimental Psychology, 18(6):643–662, 1935. doi: 10.1037/h0054651
1935 doi
-
[43]
LM3670 miniature step-down dc-dc converter datasheet, 2016
Texas Instruments. LM3670 miniature step-down dc-dc converter datasheet, 2016. URLhttps: //www.ti.com/lit/ds/symlink/lm3670.pdf. Power-management component datasheet
2016
-
[44]
J. H. M. Tulen, P. Moleman, H. G. van Steenis, and F. Boomsma. Characterization of stress reactions to the stroop color word test.Pharmacology Biochemistry and Behavior, 32(1):9–15,
-
[45]
bq2409x single-cell li-ion and li-polymer charger datasheet, 2015
Texas Instruments. bq2409x single-cell li-ion and li-polymer charger datasheet, 2015. URL https://www.ti.com/lit/ds/symlink/bq24090.pdf. Battery-charging component datasheet
2015
-
[46]
Wearable respiratory sensors for health monitoring.NPG Asia Materials, 16:8, 2024
Zhifu Yin, Yang Yang, Cong Hu, Jinzhe Li, Boyu Qin, et al. Wearable respiratory sensors for health monitoring.NPG Asia Materials, 16:8, 2024. doi: 10.1038/s41427-023-00513-9
2024 doi
-
[47]
Pastor, María Teresa López, and Antonio Fernández-Caballero
Rafael Zangróniz, Arturo Martínez-Rodrigo, José M. Pastor, María Teresa López, and Antonio Fernández-Caballero. Electrodermal activity sensor for classification of calm/distress condition. Sensors, 17(10):2324, 2017
2017
-
[48]
Zhengbo Zhang, Ikaro Silva, Dalei Wu, Jiewen Zheng, Hao Wu, and Weidong Wang. Adaptive motion artefact reduction in respiration and ECG signals for wearable healthcare monitoring systems.Medical and Biological Engineering and Computing, 52(12):1019–1030, 2014. doi: 10.1007/s11...
2014 doi
-
[49]
Piezoresistive breathing sensing system with 3d printed wearable casing
Edwin Vanegas, Raul Igual, and Inmaculada Plaza. Piezoresistive breathing sensing system with 3d printed wearable casing. InProceedings of the IEEE International Conference on Consumer Electronics, 2019
2019
-
[1989]
doi: 10.1016/0091-3057(89)90204-9
-
[2013]
doi: 10.5755/j01.eee.19.7.2232
-
[2019]
doi: 10.3390/s19040781
Reviewed August 8, 2026 · model on record in the stance chip above.
Discussion (0). Continue with ORCID to comment.