pith. sign in

arxiv: 1010.4489 · v1 · pith:7VKSPH6Enew · submitted 2010-10-21 · 🌌 astro-ph.CO

GMRT observation towards detecting the Post-reionization 21-cm signal

classification 🌌 astro-ph.CO
keywords deltasignalamplitudeforegroundsresidualacrossangularbandwidth
0
0 comments X p. Extension
pith:7VKSPH6E Add to your LaTeX paper What is a Pith Number?
\usepackage{pith}
\pithnumber{7VKSPH6E}

Prints a linked pith:7VKSPH6E badge after your title and writes the identifier into PDF metadata. Compiles on arXiv with no extra files. Learn more

read the original abstract

We have analyzed 610 MHz GMRT observations towards detecting the redshifted 21-cm signal from z=1.32. The multi-frequency angular power spectrum C_l(Delta nu) is used to characterize the statistical properties of the background radiation across angular scales ~20" to 10', and a frequency bandwidth of 7.5 MHz with resolution 125 kHz. The measured C_l(Delta nu) which ranges from 7 mK^2 to 18 mK^2 is dominated by foregrounds, the expected HI signal C_l^HI(Delta nu) ~10^{-6}- 10^{-7} mK^2 is several orders of magnitude smaller. The foregrounds, believed to originate from continuum sources, is expected to vary smoothly with Delta nu whereas the HI signal decorrelates within ~0.5 MHz and this holds the promise of separating the two. For each l, we use the interval 0.5 < Delta nu < 7.5 MHz to fit a fourth order polynomial which is subtracted from the measured C_l(Delta nu) to remove any smoothly varying component across the entire bandwidth Delta nu < 7.5 MHz. The residual C_l(Delta nu), we find, has an oscillatory pattern with amplitude and period respectively ~0.1 mK^2 and Delta nu = 3 MHz at the smallest l value of 1476, and the amplitude and period decreasing with increasing l. Applying a suitably chosen high pass filter, we are able to remove the residual oscillatory pattern for l=1476 where the residual C_l(Delta nu) is now consistent with zero at the 3-sigma noise level. We conclude that we have successfully removed the foregrounds at l=1476 and the residuals are consistent with noise. We use this to place an upper limit on the HI signal whose amplitude is determined by x_HI b where x_HI and b are the HI neutral fraction and the HI bias respectively. A value of x_HI b greater than 7.95 would have been detected in our observation, and is therefore ruled out at the 3-sigma level. (abridged)

This paper has not been read by Pith yet.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.