Pith. sign in

REVIEW 3 cited by

The EBEX Balloon Borne Experiment - Detectors and Readout

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 1803.01018 v2 pith:AYVYX52M submitted 2018-03-02 astro-ph.IM

classification astro-ph.IM
keywords bandsballoonrespectivelyebexexperimentmeasuredmediannoise
verification ladder T0 review T1 audit T2 compute T3 formal

Signed reviews

No signed human review yet.

0 comments
abstract

EBEX was a long-duration balloon-borne experiment to measure the polarization of the cosmic microwave background. The experiment had three frequency bands centered at 150, 250, and 410 GHz and was the first to use a kilo-pixel array of transition edge sensor (TES) bolometers aboard a balloon platform; shortly after reaching float we operated 504, 342, and 109 TESs at each of the bands, respectively. We describe the design and characterization of the array and the readout system. We give the distributions of measured thermal conductances, normal resistances, and transition temperatures. With the exception of the thermal conductance at 150 GHz. We measured median low-loop-gain time constants $\tau_{0}=$ 88, 46, and 57 ms and compare them to predictions. Two measurements of bolometer absorption efficiency show high ($\sim$0.9) efficiency at 150 GHz and medium ($\sim$0.35, and $\sim$0.25) at the two higher bands, respectively. We measure a median total optical load of 3.6, 5.3 and 5.0 pW absorbed at the three bands, respectively. EBEX pioneered the use of the digital version of the frequency domain multiplexing (FDM) system which multiplexed the bias and readout of 16 bolometers onto two wires. We present accounting of the measured noise equivalent power. The median per-detector noise equivalent temperatures referred to a black body with a temperature of 2.725 K are 400, 920, and 14500 $\mu$K$\sqrt{s}$ for the three bands, respectively. We compare these values to our pre-flight predictions and to a previous balloon payload, discuss the sources of excess noise, and the path for a future payload to make full use of the balloon environment.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 3 Pith papers

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. An Open Source RFSoC-based Readout Electronics System for Arrays of Kinetic Inductance Detectors and Superconducting Resonators

    physics.ins-det 2026-08 conditional novelty 4.0 of 10

    A two-channel RFSoC-based readout system reads up to 2048 kinetic inductance detectors with noise low enough for detector-limited operation on sky.

  2. Microwave Spectro-Polarimetry of Matter and Radiation across Space and Time

    astro-ph.CO 2019-09 unverdicted novelty 4.0 of 10

    This white paper proposes a large space mission combining a polarized imager, a filter-bank spectrometer, and absolute spectrometers to map the microwave sky from 10 to 2000 GHz and probe cosmology across cosmic time.

  3. Quantum measurement systems and applications to particle physics and cosmology

    physics.ins-det 2025-08 unverdicted novelty 1.0 of 10

    A survey of quantum-enhanced measurement technologies and their proposed applications to particle physics and cosmology, with a forward-looking discussion of new detector ideas.

Pith tools