Pith. sign in

REVIEW 1 cited by

Skin Cancer Detection utilizing Deep Learning: Classification of Skin Lesion Images using a Vision Transformer

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2407.18554 v2 pith:EURTLNDE submitted 2024-07-26 cs.CV

classification cs.CV
keywords skinaccuracycancerdetectionmelanomaachievesclassifiercnns
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
read the original abstract

Skin cancer detection still represents a major challenge in healthcare. Common detection methods can be lengthy and require human assistance which falls short in many countries. Previous research demonstrates how convolutional neural networks (CNNs) can help effectively through both automation and an accuracy that is comparable to the human level. However, despite the progress in previous decades, the precision is still limited, leading to substantial misclassifications that have a serious impact on people's health. Hence, we employ a Vision Transformer (ViT) that has been developed in recent years based on the idea of a self-attention mechanism, specifically two configurations of a pre-trained ViT. We generally find superior metrics for classifying skin lesions after comparing them to base models such as decision tree classifier and k-nearest neighbor (KNN) classifier, as well as to CNNs and less complex ViTs. In particular, we attach greater importance to the performance of melanoma, which is the most lethal type of skin cancer. The ViT-L32 model achieves an accuracy of 91.57% and a melanoma recall of 58.54%, while ViT-L16 achieves an accuracy of 92.79% and a melanoma recall of 56.10%. This offers a potential tool for faster and more accurate diagnoses and an overall improvement for the healthcare sector.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. TRUST: Test-time Resource Utilization for Superior Trustworthiness

    cs.LG 2025-06 conditional novelty 5.0 of 10

    TRUST computes confidence as the angular distance between a test image and a slightly modified, maximally-confident version of it, and claims this ranks predictions monotonically.

Pith tools