Pith. sign in

REVIEW 1 cited by

Heart Sound Classification Considering Additive Noise and Convolutional Distortion

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2106.01865 v1 pith:F3G7ZLPA submitted 2021-06-03 cs.SD cs.AIeess.AS

classification cs.SDcs.AIeess.AS
keywords heartnoiseabnormalitycardiacdetectionfeaturesmethodproposed
verification ladder T0 review T1 audit T2 compute T3 formal

Signed reviews

No signed human review yet.

0 comments
read the original abstract

Cardiac auscultation is an essential point-of-care method used for the early diagnosis of heart diseases. Automatic analysis of heart sounds for abnormality detection is faced with the challenges of additive noise and sensor-dependent degradation. This paper aims to develop methods to address the cardiac abnormality detection problem when both types of distortions are present in the cardiac auscultation sound. We first mathematically analyze the effect of additive and convolutional noise on short-term filterbank-based features and a Convolutional Neural Network (CNN) layer. Based on the analysis, we propose a combination of linear and logarithmic spectrogram-image features. These 2D features are provided as input to a residual CNN network (ResNet) for heart sound abnormality detection. Experimental validation is performed on an open-access heart sound abnormality detection dataset involving noisy recordings obtained from multiple stethoscope sensors. The proposed method achieves significantly improved results compared to the conventional approaches, with an area under the ROC (receiver operating characteristics) curve (AUC) of 91.36%, F-1 score of 84.09%, and Macc (mean of sensitivity and specificity) of 85.08%. We also show that the proposed method shows the best mean accuracy across different source domains including stethoscope and noise variability, demonstrating its effectiveness in different recording conditions. The proposed combination of linear and logarithmic features along with the ResNet classifier effectively minimizes the impact of background noise and sensor variability for classifying phonocardiogram (PCG) signals. The proposed method paves the way towards developing computer-aided cardiac auscultation systems in noisy environments using low-cost stethoscopes.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. Scaling to Multimodal and Multichannel Heart Sound Classification with Synthetic and Augmented Biosignals

    cs.SD 2025-09 conditional novelty 5.0 of 10

    Fine-tuning Wav2Vec2 on diffusion-generated and augmented biosignals improves abnormal heart sound classification across single-channel, PCG+ECG, and multichannel PCG data, with reported state-of-the-art benchmark numbers.

Pith tools