REVIEW 1 cited by
Calibration of the CMS hadron calorimeters using proton-proton collision data at sqrt{s} = 13 TeV
Not yet reviewed by Pith; the record is open.
This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.
SPECIMEN: schema-true, not a live event
T0 review · schema-true
One-sentence machine reading of the paper's core claim.
pith:XXXXXXXX · record.json · timestamp
Calibration of the CMS hadron calorimeters using proton-proton collision data at sqrt{s} = 13 TeV
read the original abstract
Methods are presented for calibrating the hadron calorimeter system of the CMS detector at the LHC. The hadron calorimeters of the CMS experiment are sampling calorimeters of brass and scintillator, and are in the form of one central detector and two endcaps. These calorimeters cover pseudorapidities $|\eta| <$ 3 and are positioned inside a solenoidal magnet. An outer calorimeter, outside the magnet coil, covers $|\eta| <$ 1.26, and a steel and quartz-fiber Cherenkov forward calorimeter extends the coverage to $|\eta| <$ 5.19. The initial calibration of the calorimeters was based on results from test beams, augmented with the use of radioactive sources and lasers. The calibration was improved substantially using proton-proton collision data collected at $\sqrt{s} =$ 7, 8, and 13 TeV, as well as cosmic ray muon data collected during the periods when the LHC beams were not present. The present calibration is performed using the early 13 TeV data collected during 2016 corresponding to an integrated luminosity of 35.9 fb$^{-1}$. The intercalibration of channels exploits the approximate uniformity of energy deposit over the azimuthal angle. The absolute energy scale of the central and endcap calorimeters is set using isolated charged hadrons. The energy scale for the electromagnetic portion of the forward calorimeters is set using Z $\to$ ee data. The energy scale of the outer calorimeters has been determined with test beam data and is confirmed through data with high transverse momentum jets. In this paper, we present the details of the calibration methods and accuracy.
Forward citations
Cited by 1 Pith paper
-
Measurement of the $\gamma\gamma \to \tau \tau$ cross section and constraints on the anomalous magnetic moment of the $\tau$ lepton in ultraperipheral PbPb collisions at $\sqrt{s_\mathrm{NN}}$ = 5.02 TeV
CMS measures gamma-gamma -> tau+tau- in PbPb UPCs and constrains the tau anomalous magnetic moment to -0.039 < a_tau < 0.032 (95% CL), with a fiducial cross-section of 555+60-14 microbarns.
discussion (0)
Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.